Determination of organophosphate and carbamate pesticides in spiked samples of tap water and fruit juices by a biosensor with photothermal detection

Biosensors and Bioelectronics - Tập 14 - Trang 569-578 - 1999
Lea Pogačnik1,2, Mladen Franko1,2
1Nova Gorica Politechnic, Vipavska 13, SI-5000 Nova Gorica, Slovenia
2‘Jozef Stefan’ Institute, Jamova 39, SI-1001, Ljubljana, Slovenia

Tài liệu tham khảo

Basanta, 1995, Measurement of cholinesterase activity inhibition for the detection of organophosphorous and carbamate pesticides in water, Int. J. Environ. Stud., 48, 211, 10.1080/00207239508710991 Bauman, 1965, Preparation of immobilized cholinesterase for use in analytical chemistry, Anal. Chem., 37, 1378, 10.1021/ac60230a023 Bernabei, 1993, Anticholinesterase activity measurement by a choline biosensor: application in water analysis, Biosens. Bioelectron., 8, 265, 10.1016/0956-5663(93)80014-G Besombes, 1995, A biosensor as warning device for the detection of cyanide, chlorphenols, atrazine and carbamate pesticides, Anal. Chim. Acta, 311, 255, 10.1016/0003-2670(94)00686-G Cremisini, 1995, Evaluation of the use of free and immobilised acetylcholinesterase for paraoxon detection with amperometric choline oxidase based biosensor, Anal. Chim. Acta, 311, 273, 10.1016/0003-2670(94)00618-V Dovichi, 1987, Thermo-optical spectrophotometries in analytical chemistry, CRC Crit. Rev. Anal. Chem., 17, 357, 10.1080/10408348708085560 Dzydevich, 1994, Conductometric biosensors based on cholinesterases for sensitive detection of pesticides, Electroanalysis, 6, 752, 10.1002/elan.1140060907 Ellman, 1961, A new rapid colorimetric determination of acetylcholinesterase activity, Biochem. Pharmacol., 7, 88, 10.1016/0006-2952(61)90145-9 Fernández-Romero, 1993, Flow-through optical biosensor based on the permanent immobilization of an enzyme and transient retention of a reaction product, Anal. Chem., 65, 3048, 10.1021/ac00069a017 Franko, 1996, Analytical thermal lens instrumentation, Rev. Sci. Instrum., 67, 1, 10.1063/1.1147512 Garcı́a de Marı́a, 1994, Reactivation of an immobilized enzyme reactor for the determination of acetylcholinesterase inhibitors. Flow injection determination of paraoxon, Anal. Chim. Acta, 295, 287, 10.1016/0003-2670(94)80234-3 Günther, 1995, Characterisation of inhibitors of acetylcholinesterase by an automated amperometric flow-injection system, Anal. Chim. Acta, 300, 117, 10.1016/0003-2670(94)00352-M Hartley, 1994, Amperometric measurement of organophosphate pesticides using a screen-printed disposable sensor and biosensor based on cobalt phthalocyanine, Anal. Proc., 31, 333, 10.1039/ai9943100333 Höbel, 1992, Fiber optic biosensor for pesticides based on acetylcholinesterase, Fresenius Anal. Chem., 343, 101, 10.1007/BF00332042 Ivnitskii, 1994, A potentiometric biosensor for pesticides based on the thiocholine hexacyanoferrate (III) reaction, Biosens. Bioelectron., 9, 569, 10.1016/0956-5663(94)80049-9 Kumaran, 1992, Determination of organophosphorous and carbamate insecticides by flow-injection analysis, Anal. Biochem., 200, 187, 10.1016/0003-2697(92)90297-K La Rosa, 1995, Amperometric flow-through biosensor for determination of pesticides, Anal. Chim. Acta, 308, 129, 10.1016/0003-2670(94)00529-U Lui, 1996, Immobilized enzyme modulator microassay (IEMMA) for the detection of pesticide in fresh produce, Anal. Chim. Acta, 329, 297, 10.1016/0003-2670(96)00127-4 Martonell, 1994, Amperometric determination of pesticides using a biosensor based on a polishable graphite-epoxy biocomposite, Anal. Chim. Acta, 290, 343, 10.1016/0003-2670(94)80121-5 Marty, 1995, Validation of an enzymatic biosensor with various liquid chromatographic techniques for determining organophosphorous pesticides and carbaryl in freeze-dried waters, Anal. Chim. Acta, 311, 265, 10.1016/0003-2670(94)00617-U Ministry of Health of the Republic of Slovenia, 1998. Handbook of pesticide toxicological properties in the Republic of Slovenia (Priročnik o toksikoloških lastnostih pesticidov v Republiki Sloveniji). Vesna Ternifi, Ljubljana, pp. 144–434. Mionetto, 1994, Acetylcholinesterase in organic solvents for the detection of pesticides: Biosensor application, Biosens. Bioelectron., 9, 463, 10.1016/0956-5663(94)90035-3 Moris, 1995, Chemiluminiscence assays of organophosphorous and carbamate pesticides, Anal. Chim. Acta, 302, 53, 10.1016/0003-2670(94)00432-L Nunes, 1998, Determination of carbamate residues in crop samples by cholinesterase-based biosensors and chromatographic techniques, Anal. Chim. Acta, 362, 59, 10.1016/S0003-2670(97)00547-3 Palleschi, 1992, Determination of organophosphorous insecticides with a choline electrochemical biosensor, Sens. Actuators B, 7, 513, 10.1016/0925-4005(92)80355-2 Ristori, 1996, Potentiometric detection of pesticides in water samples, Anal. Chim. Acta, 325, 151, 10.1016/0003-2670(96)00023-2 Roda, 1994, Chemiluminescent flow sensor for determination of paraoxon and aldicarb pesticides, Anal. Chim. Acta, 294, 35, 10.1016/0003-2670(94)85043-7 Rogers, 1991, Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases, Fundam. Appl. Toxicol., 16, 810, 10.1016/0272-0590(91)90166-2 Skládal, 1997, Detection of carbamate pesticides in vegetable samples using cholinesterase-based biosensors, Electroanalysis, 9, 1083, 10.1002/elan.1140091410 Stein, 1993, Comparison of immobilization methods for the development of an acetylcholinesterase biosensor, Anal. Chim. Acta, 272, 73, 10.1016/0003-2670(93)80377-W Stoytcheva, 1995, Acetylcholinesterase-based amperometric sensor, Electroanalysis, 7, 560, 10.1002/elan.1140070610 Šalamoun, 1994, Detection of anticholinesterase agents in drinking water by use of tandem packed bed reactors with humanred blood cell acetylcholinesterase and choline oxidase in a switching flow system, Int. J. Environ. Anal. Chem., 57, 163, 10.1080/03067319408027421 Šikovec, 1995, On-line thermal lens spectrometric detection of Cr(III) and Cr(VI) after separation by ion chromatography, J. Chromatogr. A, 706, 121, 10.1016/0021-9673(95)00139-E Trojanovicz, 1995, A simple disposable potentiometric biosensor for pesticides, Chem. Anal., 40, 609