Tóm tắt

Biological microarrays with different proteins and different protein concentrations are detected without external labeling by an oblique-incidence reflectivity difference (OIRD) technique. The initial experiment results reveal that the intensities of OIRD signals can distinguish the different proteins and concentrations of protein. The OIRD technique promises feasible applications to life sciences for label-free and high-throughput detection.

Từ khóa


Tài liệu tham khảo

Shena M. Microarray Analysis. Hoboken: Wiley, 2003. 4–9 Mueller H J, Roeder T. The Experimenter Series: Microarrays. Heidelberg: Elsevier GmbH, 2005. 7–12 Eing A, Vaupel M. Imaging Ellipsometry in Biotechnology. 2nd ed. Goettingen: Nanofilm Technologie GmbH, 2002. 1–10 Zhu X D, Landry J P, Sun Y S, et al. Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in microarray format. Appl Opt, 2007, 46: 1890–1895 Chen F, Lu H B, Zhao T, et al. Real-time optical monitoring of the heteroepitaxy of oxides by an oblique-incidence reflectance difference technique. Phys Rev B, 2000, 61: 10404–10410 Wang X, Jin K J, Lu H B, et al. Movement of oxygen vacancies in oxide film during annealing observed by an optical reflectivity difference technique. J Appl Phys, 2007, 102: 053107-1–5 Fei Y Y, Zhu X D, Liu L F, et al. Oscillations in oblique-incidence optical reflection from a growth surface during layer-by-layer epitaxy. Phys Rev B, 2004, 69: 233405-1–4 Chen F, Zhao T, Fei Y Y, et al. Surface segregation of bulk oxygen on oxidation of epitaxially grown Nb-doped SrTiO3 on SrTiO3 (001). Appl Phys Lett, 2002, 80: 2889–2891 Landry J P, Zhu X D, Gregg J P. Label-free detection of microarrays of biomolecules by oblique-incidence reflectivity difference microscopy. Opt Lett, 2004, 29: 581–583 Landry J P, Sun Y S, Guo X W, et al. Protein reactions with surface-bound molecular targets detected by oblique-incidence reflectivity difference microscopes. Appl Opt, 2008, 47: 3275–3288 Zhang H Y, Lu H, Li W, et al. Detection of microarray protein biomolecules by oblique-incidence reflectivity difference technique without labeling agents. Chin Phys B, 2008, 17: 2288–2291