Design and Analysis of Customized Fixation Plate for Femoral Shaft

Springer Science and Business Media LLC - Tập 54 - Trang 148-155 - 2020
Abhishek Soni1, Bhagat Singh1
1Mechanical Engineering Department, Jaypee University of Engineering and Technology, Guna, India

Tóm tắt

In the recent years, several techniques have been used to treat femur diaphyseal fracture. Among all the traditional fixation techniques, unstable fixation remains the biggest challenge for orthopedists. Researchers have recommended new approaches to deal with diaphyseal femur fracture. However, solely few had been successful in getting some better results. In the present work, a methodology comprising of design and finite-element analysis of a counter fit customized fixation plate has been suggested to provide a stable fixation. In the present work, reverse engineering (RE) approach has been invoked to create a 3D model of a fresh fractured femur diaphysis bone using the computed tomography (CT) scan data available in digital imaging and communications in medicine (DICOM) format. To provide stable fixation, a counter fit customized fixation plate at medial side has been designed and simulated under static physiological loading conditions for three different biocompatible materials, viz., titanium alloy (Ti6Al4V), stainless steel (SS-316L), and cobalt–chromium–molybdenum alloy (Co–Cr–Mo). Static stress distribution and deformation analysis of the clinical setup have been performed for the aforementioned materials. It has been observed that the stresses and deformation developed in all the materials are quite low. It implies that customized fixation plates will provide stable fixation resulting in improved fracture union. The proposed work will assist the medical practitioners regarding the design and analysis of customized implants. This will reduce the post surgical failures and residual pain due to non-union fractured region.

Tài liệu tham khảo

Jiang, Y., Guo, Y. F., Meng, Y. K., Zhu, L., & Chen, A. M. (2016). A report of a novel technique: The comprehensive fibular autograft with double metal locking plate fixation (cFALP) for refractory post-operative diaphyseal femur fracture non-union treatment. Injury,47, 2307–2311. Ricci, W. M., Gallagher, B., & Haidukewych, G. J. (2009). Intramedullary nailing of femoral shaft fractures: Current concepts. JAAOS Journal of the American Academy of Orthopaedic Surgeons,17, 296–305. Pihlajamäki, H. K., Salminen, S. T., & Böstman, O. M. (2002). The treatment of nonunions following intramedullary nailing of femoral shaft fractures. Journal of Orthopaedic Trauma,16, 394–402. Ma, L., Zhao, Z., Zhang, B., Jiang, W., Fu, L., Zhang, X., et al. (2018). Three-dimensional augmented reality surgical navigation with hybrid optical and electromagnetic tracking for distal intramedullary nail interlocking. The International Journal of Medical Robotics and Computer Assisted Surgery,14, e1909. Foote, C. J., Guyatt, G. H., Vignesh, K. N., Mundi, R., Chaudhry, H., Heels-Ansdell, D., et al. (2015). Which surgical treatment for open tibial shaft fractures results in the fewest reoperations? A network meta-analysis. Clinical Orthopaedics and Related Research,473(7), 2179–2192. Ricci, W. M., Bellabarba, C., Lewis, R., Evanoff, B., Herscovici, D., DiPasquale, T., et al. (2001). Angular malalignment after intramedullary nailing of femoral shaft fractures. Journal of Orthopaedic Trauma,15, 90–95. Winquist, R. A., Hansen, S. T., Jr., & Clawson, D. K. (2001). Closed intramedullary nailing of femoral fractures: A report of five hundred and twenty cases. JBJS,83, 1912. Ricci, W., Devinney, S., Haidukewych, G., Herscovici, D., & Sanders, R. (2008). Trochanteric nail insertion for the treatment of femoral shaft fractures. Journal of Orthopaedic Trauma,22, S2. Ricci, W. M., Bellabarba, C., Evanoff, B., Herscovici, D., & DiPasquale, T. (2001). Retrograde versus antegrade nailing of femoral shaft fractures. Journal of Orthopaedic Trauma,15, 161–169. Harris, I., Hatfield, A., & Walton, J. (2005). Assessing leg length discrepancy after femoral fracture: clinical examination or computed tomography? ANZ Journal of Surgery,75, 319–321. Reina, R., Vilella, F. E., Ramírez, N., Valenzuela, R., Nieves, G., & Foy, C. A. (2007). Knee pain and leg-length discrepancy after retrograde femoral nailing. American Journal of Orthopedics-Belle Mead,36, 325. Malik, M. H. A., Harwood, P., Diggle, P., & Khan, S. A. (2004). Factors affecting rates of infection and nonunion in intramedullary nailing. The Journal of Bone and Joint Surgery.,86, 556–560. Winquist, R. A., Sigvard, H., Jr., & Clawson, D. K. (2005). Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. Orthopedic Trauma Directions,3, 29–31. Kempf, I., Grosse, A., & Beck, G. (1985). Closed locked intramedullary nailing. Its application to comminuted fractures of the femur. JBJS,67, 709–720. Wolinsky, P. R., McCarty, E., Shyr, Y., & Johnson, K. (1999). Reamed intramedullary nailing of the femur: 551 cases. Journal of Trauma and Acute Care Surgery,46, 392–399. Canadian, O. T. S. (2003). Nonunion following intramedullary nailing of the femur with and without reaming. Results of a multicenter randomized clinical trial. The Journal of Bone and Joint Surgery,85, 2093. Gefen, A. (2002). Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation. Medical Engineering and Physics,24, 337–347. Finkemeier, C. G., & Chapman, M. W. (2002). Treatment of femoral diaphyseal nonunions. Clinical Orthopaedics and Related Research,398, 223–234. Crowley, D. J., Kanakaris, N. K., & Giannoudis, P. V. (2007). Femoral diaphyseal aseptic non-unions: is there an ideal method of treatment? Injury,38, S55–S63. Raja, V., & Fernandes, K. J. (2007). Reverse engineering: an industrial perspective. Berlin: Springer Science and Business Media. Laplante, P. A. (2000). Dictionary of computer science, engineering and technology. Boca Raton: CRC Press. Marro, A., Bandukwala, T., & Mak, W. (2016). Three-dimensional printing and medical imaging: a review of the methods and applications. Current Problems in Diagnostic Radiology,45, 2–9. Gibson, I., Cheung, L. K., Chow, S. P., Cheung, W. L., Beh, S. L., Savalani, M., et al. (2006). The use of rapid prototyping to assist medical applications. Rapid Prototyping Journal,12, 53–58. Lin, Y.-P., Wang, C.-T., & Dai, K.-R. (2005). Reverse engineering in CAD model reconstruction of customized artificial joint. Medical Engineering and Physics,27, 189–193. George, S. P., & Saravana Kumar, G. (2013). Patient specific parametric geometric modelling and finite element analysis of cementless hip prosthesis: This paper proposes a framework for subject-specific cementless hip implant design and virtual assembly analysis of the instantiated stem with femur model using finite element method. Virtual and Physical Prototyping,8, 65–83. Jardini, A. L., Larosa, M. A., de Carvalho Zavaglia, C. A., Bernardes, L. F., Lambert, C. S., Kharmandayan, P., et al. (2014). Customised titanium implant fabricated in additive manufacturing for craniomaxillofacial surgery: This paper discusses the design and fabrication of a metallic implant for the reconstruction of a large cranial defect. Virtual and physical prototyping,9, 115–125. Su, X. B., Yang, Y. Q., Peng, Y. U., & Sun, J. F. (2012). Development of porous medical implant scaffolds via laser additive manufacturing. Transactions of Nonferrous Metals Society of China,22, s181–s187. Narra, N., Valasek, J., Hannula, M., Marcian, P., Sandor, G. K., Hyttinen, J., et al. (2014). Finite element analysis of customized reconstruction plates for mandibular continuity defect therapy. Journal of Biomechanics,47, 264–268. Thomas, D., Azmi, M. M., & Tehrani, Z. (2014). 3D additive manufacture of oral and maxillofacial surgical models for preoperative planning. The International Journal of Advanced Manufacturing Technology,71, 1643–1651. Shin, D. S., Lee, K., & Kim, D. (2007). Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Computer-Aided Design,39, 559–567.