Dental implant design–effect on bone remodeling

Wiley - Tập 25 Số 4 - Trang 467-483 - 1991
Robert M. Pilliar1, Douglas Deporter1, Philip Watson1, Nancy Valiquette1
1MRC Dental Implant Program, University of Toronto, Faculty of Dentistry, Toronto, Ontario, Canada, M5G 1G6

Tóm tắt

AbstractBone remodeling around three different endossesous dental implant designs placed in dog mandibles was studied using radiography during lengthy periods of function and by histology after animal sacrifice. The three designs investigated were (a) threaded (c.p. titanium), (b) fully porous‐coated (titanium alloy), and (c) partially porous‐coated (titanium alloy). The implants were kept in function for either 32 weeks (fully porous‐coated) or 73 to 77 weeks (partially porous‐coated and threaded). The studies indicated that some crestal bone loss occurred for both the threaded and partially porous‐coated implants while no significant bone loss was seen with fully porous‐coated implants in the absence of plaque‐associated infection. It is suggested that these observed differences are a result of the different stress states that develop in bone surrounding the three designs underlying the importance of implant design on bone remodeling.

Từ khóa


Tài liệu tham khảo

Branemark P.‐I., 1977, Osseointegrated implants in the treatment of edentulous jaw. Experience from a 10‐year period, Scand. J. Plast. Reconstr. Surg. Suppl., 16

Cox J. F., 1987, The longitudinal clinical efficacy of osseointegrated dental implants: A 3‐year report, Int. J. Oral Maxillofacial Implants, 2, 91

10.1016/S0300-9785(81)80077-4

Pilliar R. M., 1987, Porous‐surfaced metallic implants for orthopaedic applications, J. Biomed. Mater. Res. Appl. Biomater., 21, 1

10.1177/00220345860650080601

10.1177/00220345860650080501

10.1177/00220345880670090801

10.1177/00220345900690050401

Maniatopoulos C., 1986, An improved method for preparing histological sections of metallic implants, J. Int. Oral Maxillofac. Implantol., 1, 31

10.1002/jor.1100050312

10.3109/17453678108991775

Takuma M., 1989, Local stresses and bone remodelling around distal implants, J. Dent. Res., 68, 872

10.1007/978-94-009-7678-8_53

Cunningham W. P., 1990, Finite element analysis comparing IMZ dental implant to mandibular cuspid, J. Dent Res., 69, 116

Hata Y., 1990, Stress analysis of intermobile element by three dimensional finite element, J. Dent Res., 69, 117

Buch J. D., 1978, Biomechanical and biomaterials considerations of natural teeth, tooth replacement and skeletal fixation, Biomater., Med. Dev., Artif. Organs, 2, 171, 10.3109/10731197409118961

10.1002/jbm.820150612

10.1016/0021-9290(81)90005-1

10.1177/00220345820610080201

Vaillancourt H., 1990, Development and Design with Advanced Materials, 207

H.Vaillancourt Dept. of Mech. Eng. University of Toronto personal communication 1990.

10.1177/00220345800590022001

10.1016/0022-3913(79)90094-5

Larheim T. A., 1984, Comparison of bone resorption at one‐step and two‐step mandibular endosseous implants in dogs, Scand. J. Dent. Res., 92, 84

McKinney R. V., 1983, The single crystal sapphire endosseous dental implant. II, Two year results of clinical animal trials, J. Oral Implantology, 11, 619

10.2106/00004623-198163060-00017

10.1002/jbm.820130510

10.1002/jbm.820150610

Engh C. A., 1987, Porous coated hip replacement: A study of factors governing bone ingrowth, stress shielding and clinical results, J. Bone Joint Surg., 69, 45, 10.1302/0301-620X.69B1.3818732

10.1016/0021-9290(87)90029-7

10.1016/0021-9290(84)90135-0

Perren S. M., 1988, Early temporary porosis of bone induced by internal fixation implants, Clin. Orthop. Rel. Res., 232, 139, 10.1097/00003086-198807000-00018

Brown I. W., 1985, Osteolytic changes in the upper femoral shaft following porous‐coated hip replacement, J. Bone Joint Surg., 67, 218, 10.1302/0301-620X.67B2.3980529