Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation
Tài liệu tham khảo
Ohara, 1989, Irradiation synchronized with respiration gate, Int J Radiat Oncol Biol Phys, 17, 853, 10.1016/0360-3016(89)90078-3
Ross, 1990, Analysis of movement of intrathoracic neoplasms using ultrafast computed tomography, Int J Radiat Oncol Biol Phys, 18, 671, 10.1016/0360-3016(90)90076-V
Kubo, 1996, Respiration gated radiotherapy treatment, Phys Med Biol, 41, 83, 10.1088/0031-9155/41/1/007
Steene, 1998, Electronic portal imaging with on-line correction of setup error in thoracic irradiation, Int J Radiat Oncol Biol Phys, 40, 967, 10.1016/S0360-3016(97)00925-5
Frohlich, 1985, A simple device for breath-level monitoring during CT, Radiology, 156, 235, 10.1148/radiology.156.1.4001413
Kalender, 1990, Measurement of pulmonary parenchymal attenuation, Radiology, 175, 265, 10.1148/radiology.175.1.2315492
Okumara T, Tsuji H, Hayakawa Y; et al. Respiration-gated irradiation system for proton radiotherapy. Proceedings of the 11th International Conference on the Use of Computers in Radiation Therapy. Manchester, UK: North Western Medical Physics Dept., Christie Hospital; 1994.
Wong, 1998, Treatment with active breathing control (ABC) in the thoracic and upper abdominal regions, Med Phys, 25, A127
Emami, 1991, Tolerance of normal tissue to therapeutic irradiation, Int J Radiat Oncol Biol Phys, 21, 109, 10.1016/0360-3016(91)90171-Y
Martel, 1992, Dose-volume histogram and 3-D/CT treatment planning evaluation of patients with radiation pneumonitis, Int J Radiat Oncol Biol Phys, 24, 175, 10.1016/0360-3016(92)90218-7
Armstrong, 1993, Three-dimensional conformal therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancer, Int J Radiat Oncol Biol Phys, 26, 685, 10.1016/0360-3016(93)90289-8
1994, Standardization of spirometry, AJRCCM, 152
Mohan, 1988, A comprehensive three-dimensional radiation treatment planning system, Int J Radiat Oncol Biol Phys, 15, 481, 10.1016/S0360-3016(98)90033-5
Ekstrand, 1990, Pitfalls in the use of high energy x rays to treat tumors in the lung, Int J Radiat Oncol Biol Phys, 18, 249, 10.1016/0360-3016(90)90290-Z
Kutcher, 1991, Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations, Int J Radiat Oncol Biol Phys, 21, 137, 10.1016/0360-3016(91)90173-2
Lyman, 1985, Complication probability as assessed from dose-volume histograms, Radiat Res, 104, S13, 10.2307/3576626
Terahara, 1998, Relationship between respiration gated irradiation and actual respiratory movement of tumors, Radiother Oncol, 48, S47
El-Khatib, 1986, Accuracy of lung dose calculations for large-field irradiation with 6 MV x-rays, Med Phys, 13, 111, 10.1118/1.595953
Klein, 1993, The influence of air cavities on interface doses for photon beams, Int J Radiat Oncol Biol Phys, 27, 419, 10.1016/0360-3016(93)90255-T
Mohan, 1991, Role of inhomogeneity corrections in three-dimensional photon treatment planning, Int J Radiat Oncol Biol Phys, 21, 59, 10.1016/0360-3016(91)90167-3
White, 1996, Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons, Int J Radiat Oncol Biol Phys, 34, 10.1016/0360-3016(95)02384-4
Debois, 1996, Verification of inflation level and lung position during breath hold lung treatment using on-line imaging, Med Phys, 23, 1082