Cytotoxic effects of surface-modified quantum dots on neuron-like PC12 cells cultured inside microfluidic devices

BioChip Journal - Tập 4 - Trang 82-88 - 2010
Sanjeev Kumar Mahto1, Tae Hyun Yoon2, Seog Woo Rhee1
1Department of Chemistry, College of Natural Sciences, Kongju National University, Gongju, Korea
2Department of Chemistry, College of Natural Sciences, Hanyang University, Seoul, Korea

Tóm tắt

This paper describes the cytotoxic effects of surface-modified quantum dots (QDs) on neuronlike PC12 cells under localized exposure conditions. PC12 cells were cultured and differentiated on a two-compartment microfluidic neuronal device with the aim of preferentially isolating axons from their cell bodies and thus providing localized exposure of cell bodies or axons to QDs. In addition, we used two distinct ligands for surface modification of QDs: mercaptopropionic acid (MPA) and cetyltrimethylammonium bromide/trioctylphosphine oxide (CTAB/TOPO). The results showed that CTAB/TOPO-QDs were toxic to neurons, whereas MPA-QDs were non-toxic. Through general morphological observation, we observed remarkable alterations in the morphology of the neurons induced by CTAB/TOPO-QDs such as cell shrinkage and axonal degeneration. Furthermore, to investigate whether the axonal degeneration was a consequence of neuronal cell death or was due to a direct toxic effect of QDs on axons, preferentially isolated cell bodies and axons were locally exposed to CTAB/TOPO-QDs, followed by an analysis of intracellular reactive oxygen species (ROS) formation and nuclear changes. The results suggested that axonal degeneration could be a consequence of neuronal cell death as well as of direct axonal toxicity. An estimation of the amount of ROS in neurons exposed to CTAB/TOPOQDs further suggested that oxidative stress could be a leading cause of axonal degeneration and consequent toxicity. In addition, nuclear condensation was observed to be a consequence of QD toxicity.

Tài liệu tham khảo

Andersson, H. & Berg van den, A. Microfluidic devices for cellomics: a general overview of the field. In: Lab-on-Chips for Cellomics. Springer, Berlin, Germany, pp. 1–22 (2004). Breslauer, D.N., Lee, P.J. & Lee, L.P. Microfluidics-based systems biology. Mol. BioSyst. 2, 97–112 (2006). El-Ali, J., Sorger, P.K. & Jensen, K.F. Cells on chips. Nature 442, 403–411 (2006). Manz, A., Graber, N. & Widmer, H.M. Miniaturized total chemical analysis systems: a novel concept for chemical sensing. Sens. Actuators B: Chemical 1, 244–248 (1990). Qin, J., Ye, N., Liu, X. & Lin, B. Microfluidic devices for the analysis of apoptosis. Electrophoresis 26, 3780–3788 (2005). Walker, G.M. et al. Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator. Lab. Chip 5, 611–618 (2005). Tourovskaia, A., Figueroa-Masot, X. & Folch, A. Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies. Lab. Chip 5, 14–19 (2005). King, K.R. et al. A high-throughput microfluidic realtime gene expression living cell array. Lab. Chip 7, 77–85 (2007). Thompson, D.M. et al. Dynamic gene expression profiling using a microfabricated living cell array. Anal. Chem. 76, 4098–4103 (2004). Taylor, A.M. et al. Microfluidic multicompartment device for neuroscience research. Langmuir 19, 1551–1556 (2003). Taylor, A.M. et al. A microfluidic culture platform for CNS axonal injury, regeneration and transport. Nat. Methods 2, 599–605 (2005). Nakashima, Y. & Yasuda, T. Cell differentiation guidance using chemical stimulation controlled by a microfluidic device. Sens. Actuators A 139, 252–258 (2007). Greene, L.A. & Tischler, A.S. Establishment of a noradrenergic clonal line of rat adrenal pheochromocytoma cells which respond to nerve growth factor. Proc. Natl. Acad. Sci., USA 73, 2424–2428 (1976). Tischler, A.S. & Greene, L.A. Nerve growth factor-induced process formation by cultured rat pheochromocytoma cells. Nature 258, 341–342 (1975). Chan, W.C. & Nie, S. Quantum dot bioconjugates for ultrasensitive nonisotopic detection. Science 281, 2016–2018 (1998). Chen, F.Q. & Gerion, D. Fluorescent CdSe/ZnS nanocrystal peptide conjugates for long term, nontoxic imaging and nuclear targeting in living cells. Nano Lett. 4, 1827–1832 (2004). Derfus, A.M., Chan, W.C. & Bhatia, S. Intracellular delivery of quantum dots for live cell labeling and organelle tracking. Adv. Mater. 16, 961–966 (2004). Gao, X.H. & Nie, S.M. Molecular profiling of single cells and tissue specimens with quantum dots. Trends Biotechnol. 21, 371–373 (2003). Gao, X., Cui, Y., Levenson, R.M., Chung, L.W. & Nie, S. In vivo cancer targeting and imaging with semiconductor quantum dots. Nat. Biotechnol. 22, 969–976 (2004). Derfus, A.M., Chan, W.C. & Bhatia, S. Probing the cytotoxicity of semiconductor quantum dots. Nano Lett. 4, 11–18 (2004). Tang, M. et al. Unmodified CdSe quantum dots induce elevation of cytoplasmic calcium levels and impairment of functional properties of sodium channels in rat primary cultured hippocampal neurons. Environ. Health. Perspect. 116, 915–922 (2008). Choi, A.O., Cho, S.J., Desbarats, J., Lovric, J. & Maysinger, D. Quantum dot-induced cell death involves Fas upregulation and lipid peroxidation in human neuroblastoma cells. J. Nanobiotechnol. 5, 1–13 (2007). Park, C., Kim, D.H., Kim, M.J. & Yoon, T.H. Characterization and toxicological impacts of monodisperse quantum dot nanocolloids in aqueous solution. Bull. Kor. Chem. Soc. 29, 303–304 (2008). Park, C., Lim, K.H., Kwon, D. & Yoon, T.H. Biocompatible quantum dot nanocolloids stabilized by Gum Arabic. Bull. Kor. Chem. Soc. 29, 1277–1279 (2008). Yu, W.W., Qu, L.H., Guo, W.Z. & Peng, X.G. Experimental determination of the extinction coefficient of CdTe, CdSe, and CdS nanocrystals. Chem. Mater. 15, 2854–2860 (2003).