Current status of zirconia restoration

Journal of Prosthodontic Research - Tập 57 - Trang 236-261 - 2013
Takashi Miyazaki1, Takashi Nakamura2, Hideo Matsumura3, Seiji Ban4, Taira Kobayashi5
1Division of Oral Biomaterials and Technology, Showa University School of Dentistry, Tokyo, Japan
2Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan
3Department of Fixed Prosthodontics, Nihon University School of Dentistry, Tokyo, Japan
4Department of Dental Materials Science, School of Dentistry, Aichi Gakuin University, Nagoya, Japan
5Department of Crown Bridge Prosthodontics, Nihon University School of Dentistry at Matsudo, Japan

Tài liệu tham khảo

Pjetursson, 2007, A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns, Clin Oral Implants Res, 18, 73, 10.1111/j.1600-0501.2007.01467.x Sailer, 2007, A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses, Clin Oral Implants Res, 18, 86, 10.1111/j.1600-0501.2007.01468.x Guess, 2011, All ceramic systems: laboratory and clinical performance, Dent Clin North Am, 55, 333, 10.1016/j.cden.2011.01.005 Raigrodski, 2001, The safety and efficiency of anterior ceramic fixed partial dentures: a review of the literature, J Prosthet Dent, 86, 520, 10.1067/mpr.2001.120111 Raigrodski, 2004, Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature, J Prosthet Dent, 92, 557, 10.1016/j.prosdent.2004.09.015 Heather, 2007, Current ceramic materials and systems with clinical recommendations: a systematic review, J Prosthet Dent, 98, 389, 10.1016/S0022-3913(07)60124-3 ISO6862, 2008 Christel, 1989, Mechanical properties and short-term in-vivo evaluation of yttrium-oxide partially-stabilized zirconia, J Biomed Mater Res, 23, 45, 10.1002/jbm.820230105 Guazzato, 2004, Strength, fracture toughness, and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics, Dent Mater, 20, 449, 10.1016/j.dental.2003.05.002 Hannink, 2000, Transformation toughening in zirconia-containing ceramics, J Am Ceram Soc, 83, 461, 10.1111/j.1151-2916.2000.tb01221.x Nawa, 1998, Tough and strong Ce-TZP/alumina nanocomposites doped with titania, Ceram Int, 24, 497, 10.1016/S0272-8842(97)00048-5 Tanaka, 2002, Ce-TZP/ASl2O3 nanocomposites as a bearing material in total joint replacement, J Biomed Mater Res, 63, 262, 10.1002/jbm.10182 Chevalier, 2009, The tetragonal-monoclinic transformation in zirconia: lessons learned and future trends, J Am Ceram Soc, 92, 1901, 10.1111/j.1551-2916.2009.03278.x Miyazaki, 2009, A review of dental CAD/CAM: current status and future perspectives from 20 years of experience, Dent Mater J, 28, 44, 10.4012/dmj.28.44 Beuer, 2009, High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings – a new fabrication mode for all-ceramic restorations, Dent Mater, 25, 121, 10.1016/j.dental.2008.04.019 Denry, 2008, State of the art of zirconia for dental applications, Dent Mater, 24, 299, 10.1016/j.dental.2007.05.007 Al-Ameleh, 2010, Clinical trial in zirconia: a systematic review, J Oral Rehabil, 37, 641 Strub, 2006, Computer-aided design and fabrication of dental restorations: current systems and future possibilities, J Am Dent Assoc, 137, 1289, 10.14219/jada.archive.2006.0389 Sorensen, 1991, A standardized method for determination of crown margin fidelity, J Prosthet Dent, 65, 18 Bicaro, 2013, An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns, J Prosthodont, 22, 36, 10.1111/j.1532-849X.2012.00907.x Komine, 2005, Influence of framework configuration on the marginal adaptation of zirconium dioxide ceramic anterior four-unit frameworks, Acta Odontol Scand, 63, 361, 10.1080/00016350500264313 Bindl, 2007, Fit of all-ceramic posterior fixed partial denture frameworks in vitro, Int J Periodontics Restorative Dent, 27, 567 Att, 2009, Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses, J Prosthet Dent, 101, 239, 10.1016/S0022-3913(09)60047-0 Kunii, 2007, Effect of sintering on the marginal and internal fit of CAD/CAM fabricated zirconia frameworks, Dent Mater J, 26, 820, 10.4012/dmj.26.820 Komine, 2010, Current status of zirconia-based fixed restorations, J Oral Sci, 52, 531, 10.2334/josnusd.52.531 Raigrodski, 2012, Survival and complications of zirconia-based fixed dental prostheses: a systematic review, J Prosthet Dent, 107, 170, 10.1016/S0022-3913(12)60051-1 Raigrodski, 2012, Clinical efficacy of veneered zirconium dioxide-based posterior partial fixed dental prostheses: five-year results, J Prosthet Dent, 108, 214, 10.1016/S0022-3913(12)60165-6 Fischer, 2008, Effect of zirconia surface treatments on the shear strength of zirconia/veneering ceramic composites, Dent Mater J, 27, 448, 10.4012/dmj.27.448 Omori, 2013, Effect of thickness of zirconia-ceramic crown frameworks on strength and fracture pattern, Dent Mater J, 32, 189, 10.4012/dmj.2012-255 Ban, 2010, Fracture toughness of dental zirconia before and after autoclaving, J Ceram Soc Jpn, 118, 406, 10.2109/jcersj2.118.406 Kuriyama, 2011, Novel fabrication method of zirconia restorations – bonding strength of machinable ceramics to zirconia with resin cements, Dent Mater J, 30, 419, 10.4012/dmj.2010-213 Preis, 2011, Wear performance of substructure ceramics and veneering porcelains, Dent Mater, 27, 796, 10.1016/j.dental.2011.04.001 Rosentritt, 2012, Two-body wear of dental porcelain and substructure oxide ceramics, Clin Oral Investig, 16, 935, 10.1007/s00784-011-0589-9 Burgess, 2013, Enamel wear opposing polished and aged zirconia, Oper Dent Tang, 2012, Effects of multiple firings on the mechanical properties and microstructure of veneering ceramics for zirconia frameworks, J Dent, 40, 372, 10.1016/j.jdent.2012.01.014 Belli, 2013, Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns, Dent Mater, 29, 181, 10.1016/j.dental.2012.11.015 Eisenburger, 2011, Fracture stability of anterior zirconia crowns with different core designs and veneered using the layering or the press-over technique, Eur J Oral Sci, 119, 253, 10.1111/j.1600-0722.2011.00829.x Guess, 2013, Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns, Dent Mater, 29, 307, 10.1016/j.dental.2012.11.012 Preis, 2013, Influence of substructure design, veneer application technique, and firing regime on the in vitro performance of molar zirconia crowns, Dent Mater, 29, e113, 10.1016/j.dental.2013.04.011 Fischer, 2008, Effect of zirconia surface treatments on the shear strength of zirconia/veneering ceramic composites, Dent Mater J, 27, 448, 10.4012/dmj.27.448 ISO 9693, 1999 Doi, 2011, Influence of pre-treatments on flexural strength of zirconia and debonding crack-initiation strength of veneered zirconia, J Adhes Dent, 13, 79 Tada, 2012, Influence of surface treatment on bond strength of veneering ceramics fused to zirconia, Dent Mater J, 31, 287, 10.4012/dmj.2011-163 Yamaguchi, 2012, Examination of bond strength and mechanical properties of Y-TZP zirconia ceramics with different surface modifications, Dent Mater J, 31, 472, 10.4012/dmj.2011-237 Guess, 2008, Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling, Dent Mater, 24, 1556, 10.1016/j.dental.2008.03.028 Choi, 2009, Shear bond strength of veneering porcelain to zirconia and metal cores, J Adv Prosthodont, 1, 129, 10.4047/jap.2009.1.3.129 Comlekoglu, 2008, Evaluation of bond strength of various margin ceramics to a zirconia ceramic, J Dent, 36, 822, 10.1016/j.jdent.2008.05.019 Blatz, 2010, Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling, Am J Dent, 23, 213 Fazi, 2010, Microtensile bond strength of three different veneering porcelain systems to a zirconia core for all ceramic restorations, Am J Dent, 23, 347 Gostemeyer, 2012, Effect of thermal expansion mismatch on the Y-TZP/veneer interfacial adhesion determined by strain energy release rate, J Prosthodont Res, 56, 93, 10.1016/j.jpor.2011.09.002 Queiroz, 2012, Effect of multiple firing and silica deposition on the zirconia-porcelain interface bond strength, Dent Mater, 28, 763, 10.1016/j.dental.2012.03.014 Trindade, 2013, Zirconia-porcelain bonding: effect of multiple firings on microtensile bond strength, J Adhes Dent, 15 Zeighami, 2013, The effect of multiple firings on microtensile bond strength of core-veneer zirconia-based all-ceramic restorations, J Prosthodont, 22, 49, 10.1111/j.1532-849X.2012.00889.x Komine, 2010, Effect of cooling rate on shear bond strength of veneering porcelain to a zircnoia ceramic material, J Oral Sci, 52, 647, 10.2334/josnusd.52.647 Gostemeyer, 2010, Influence of cooling rate on zircinia/veneer interfacial adhesion, Acta Biomater, 6, 4532, 10.1016/j.actbio.2010.06.026 Almeida, 2013, Effects of extreme cooling methods on mechanical properties and shear bond strength of bilayered porcelain/3Y-TZP specimens, J Dent, 41, 356, 10.1016/j.jdent.2013.01.005 Fischer, 2010, Shear bond strength between ceramics and ceria-stabilized zirconia/alumina, J Prosthet Dent, 103, 267, 10.1016/S0022-3913(10)60056-X Kim, 2011, Effect of zirconia surface treatment on the shear bond strength of veneering ceramic, J Prosthet Dent, 105, 315, 10.1016/S0022-3913(11)60060-7 Harding, 2012, The effect of surface treatment of the interfacial surface on fatigue-related microtensile bond strength on milled zirconia to veneering porcelain, J Prosthodont, 21, 346, 10.1111/j.1532-849X.2012.00843.x Casucci, 2009, Influence of different surface treatments on surface zirconia frameworks, J Dent, 37, 891, 10.1016/j.jdent.2009.06.013 Nakamura, 2009, Tensile bond strength between tooth-colored porcelain and zirconia framework, J Prosthodont Res, 53, 116, 10.1016/j.jpor.2009.02.007 Teng, 2012, Evaluation of a conditioning method to improve core-veneer bond strength of zirconia restorations, J Prosthet Dent, 107, 380, 10.1016/S0022-3913(12)60095-X Liu, 2013, A new modified laser pretreatment for porcelain zirconia bonding, Dent Mater, 29, 559, 10.1016/j.dental.2013.03.002 Ban, 2013, Surface properties of dental zirconia after clinical grinding and polishing, Key Eng Mater, 24, 501 Chintapalli, 2013, Phase transformation and subsurface damage in 3Y-TZP after sandblasting, Dent Mater, 29, 566, 10.1016/j.dental.2013.03.005 Springate, 1991, An evaluation of zirconium oxide brackets: a preliminary laboratory and clinical report, Br J Orthod, 18, 203, 10.1179/bjo.18.3.203 Kern, 1998, Bonding to zirconia ceramic: adhesion methods and their durability, Dent Mater, 14, 64, 10.1016/S0109-5641(98)00011-6 O’Keefe, 2000, In vitro tensile bond strength of adhesive cements to new post materials, Int J Prosthodont, 13, 47 Lüthy, 2006, Effect of thermocycling on bond strength of luting cements to zirconia ceramic, Dent Mater, 22, 195, 10.1016/j.dental.2005.04.016 de Oyagüe, 2009, Influence of surface treatments and resin cement selection on bonding to densely-sintered zirconium-oxide ceramic, Dent Mater, 25, 172, 10.1016/j.dental.2008.05.012 Koizumi, 2012, Bonding of resin-based luting cements to zirconia with and without the use of ceramic priming agents, J Adhes Dent, 14, 385 Saker, 2013, Effect of different surface treatments on adhesion of In-Ceram Zirconia to enamel and dentin substrates, J Adhes Dent, 15, 369 Janda, 2003, A new adhesive technology for all-ceramics, Dent Mater, 19, 567, 10.1016/S0109-5641(02)00106-9 Özcan, 2003, Effect of surface conditioning methods on the bond strength of luting cement to ceramics, Dent Mater, 19, 725, 10.1016/S0109-5641(03)00019-8 Sahafi, 2004, Effect of surface treatment of prefabricated posts on bonding of resin cement, Oper Dent, 29, 60 Ernst, 2005, In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents, J Prosthet Dent, 93, 551, 10.1016/j.prosdent.2005.04.011 Piwowarczyk, 2005, The shear bond strength between luting cements and zirconia ceramics after two pre-treatments, Oper Dent, 30, 382 Blatz, 2004, In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling, J Prosthet Dent, 91, 356, 10.1016/j.prosdent.2004.02.001 Atsu, 2006, Effect of zirconium-oxide ceramic surface treatments on the bond strength to adhesive resin, J Prosthet Dent, 95, 430, 10.1016/j.prosdent.2006.03.016 Blatz, 2007, Influence of surface treatment and simulated aging on bond strengths of luting agents to zirconia, Quintessence Int, 38, 745 Tanaka, 2008, Cooperation of phosphate monomer and silica modification on zirconia, J Dent Res, 87, 666, 10.1177/154405910808700705 Nakayama, 2010, Adhesive bonding of zirconia with single-liquid acidic primers and a tri-n-butylborane initiated acrylic resin, J Adhes Dent, 12, 305 Dérand, 2000, Bond strength of luting cements to zirconium oxide ceramics, Int J Prosthodont, 13, 131 Borges, 2003, Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics, J Prosthet Dent, 89, 479, 10.1016/S0022-3913(02)52704-9 Ban, 2008, Reliability and properties of core materials for all-ceramic dental restorations, Jpn Dent Sci Rev, 44, 3, 10.1016/j.jdsr.2008.04.001 Ban, 2008, Biaxial flexure strength and low temperature degradation of Ce-TZP/Al2O3 nanocomposite and Y-TZP as dental restoratives, J Biomed Mater Res B: Appl Biomater, 87B, 492, 10.1002/jbm.b.31131 Sato, 2008, Mechanical properties of dental zirconia ceramics changed with sandblasting and heat treatment, Dent Mater J, 27, 408, 10.4012/dmj.27.408 Yamashita, 2009, Effect of surface roughness on initial responses of osteoblast-like cells on two types of zirconia, Dent Mater J, 28, 461, 10.4012/dmj.28.461 Okuda, 2010, Radio-opacity of core materials for all-ceramic restorations, Dent Mater J, 29, 35, 10.4012/dmj.2009-54 Noda, 2010, Surface damages of zirconia by Nd:YAG dental laser irradiation, Dent Mater J, 29, 536, 10.4012/dmj.2009-127 2010, 3M ESPE Lava crowns and bridges (7 years), The Dental Advisor, 27 Bona, 2008, The clinical success of all-ceramic restorations, J Am Dent Assoc, 139, 8S, 10.14219/jada.archive.2008.0361 Baldissara, 2010, Translucency of zirconia copings made with different CAD/CAM systems, J Prosthet Dent, 104, 6, 10.1016/S0022-3913(10)60086-8 Alghazzawi, 2012, Evaluation of the optical properties of CAD-CAM generated yttria-stabilized zirconia and glass-ceramic laminate veneers, J Prosthet Dent, 107, 300, 10.1016/S0022-3913(12)60079-1 Sakakibara, 2012, Properties of dental polishing materials and devices, J Jpn Soc Dent Mater Dev, 31, 140 Ban, 2008, Caution for frame processing, 86 Ban, 2012, Polishing of zirconia full contour restoratives and antagonist wear, QDT, 32, 1240 Ohkuma, 2011, The grinding efficiency by diamond points developed for yttria partially stabilized zirconia, Dent Mater J, 30, 511, 10.4012/dmj.2010-152 Ban, 2008, Biaxial flexure strength and low temperature degradation of Ce-TZP/Al2O3 nanocomposite and Y-TZP as dental restoratives, J Biomed Mater Res B: Appl Biomater, 87, 492, 10.1002/jbm.b.31131 Ban, 2013, Current status of CAD/CAM biomaterials, J Jpn Acad CAD/CAM Dent, 3, 2 Ban, 2006, Microstructure and mechanical properties of recent dental porcelains, 58 Kumar, 1991, Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy, J Biomed Mater Res, 25, 813, 10.1002/jbm.820250703 Tambra, 2003, Wear of enamel opposing YPSZ zirconia core material with two surface finish Culver, 2008, Wear of the enamel antagonist and five restorative materials Shar, 2010, Wear of enamel on polished and glazed zirconia Jung, 2010, A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain, J Adv Prosthodont, 2, 1111, 10.4047/jap.2010.2.3.111 Albashaireh, 2010, Two-body wear of different ceramic materials opposed to zirconia ceramic, J Prosthet Dent, 104, 105, 10.1016/S0022-3913(10)60102-3 Sorensen, 2011, Three-body wear of enamel against full crown ceramics Basunbul, 2011, Human enamel wear against four dental ceramics in vitro Kuretzky, 2011, Wear behaviour of zirconia compared to state-of-the-art ceramics Yang, 2012, Antagonist enamel wear to 3 CAD/CAM full contour zirconia ceramics Janyavula, 2013, The wear of polished and glazed zirconia against enamel, J Prosthet Dent, 109, 22, 10.1016/S0022-3913(13)60005-0 Kontos, 2013, Influence of surface treatment on the wear of solid zirconia, Acta Odontol Scand, 71, 482, 10.3109/00016357.2012.696690 Stawarczyk, 2013, Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists, Acta Odontol Scand, 71, 102, 10.3109/00016357.2011.654248 Wassell, 1994, A two-body friction wear test, J Dent Res, 73, 1546, 10.1177/00220345940730091001 Wassell, 1994, Wear characteristics in a two-body wear test, Dent Mater, 10, 269, 10.1016/0109-5641(94)90073-6 Mehl, 2007, Wear of composite resin veneering materials and enamels in a chewing simulator, Dent Mater, 23, 1382, 10.1016/j.dental.2006.11.026 Ghazal, 2008, Two-body wear of resin and ceramic denture teeth in comparison to human enamel, Dent Mater, 24, 502, 10.1016/j.dental.2007.04.012 Creugers, 1994, A meta-analysis of durability data on conventional fixed bridges, Community Dent Oral Epidemiol, 22, 448, 10.1111/j.1600-0528.1994.tb00795.x Scurria, 1998, Meta-analysis of fixed partial denture survival. Prostheses and abutments, J Prosthet Dent, 79, 459, 10.1016/S0022-3913(98)70162-3 Luthardt, 1999, Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns, Eur J Prosthodont Restor Dent, 7, 113 Sjölin, 1999, The Decim system for the production of dental restorations, Int J Comput Dent, 2, 197 Vult von Steyern, 2006, Fracture strength of two oxide ceramic crown systems after cyclic pre-loading and thermocycling, J Oral Rehabil, 33, 682, 10.1111/j.1365-2842.2005.01604.x Fritzsche, 2003, Zirconium oxide restorations with the DCS precident system, Int J Comput Dent, 6, 193 Paolo, 2012, Evaluation of zirconium-oxide-based ceramic single-unit posteriorfixed dental prostheses (FDPs) generated with two CAD/CAM systems compared to porcelain-fused-to-metal single-unit posterior FDPs: A 5-year clinical prospective study, J Prosthodont, 21, 265, 10.1111/j.1532-849X.2011.00825.x Thompson, 1994, Fracture surface characterization of clinically failed all-ceramic crowns, J Dent Res, 73, 1824, 10.1177/00220345940730120601 Kelly, 1990, Fracture surface analysis of dental ceramics: clinically failed restorations, Int J Prosthodont, 3, 430 Kelly, 1995, Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling, J Dent Res, 74, 1253, 10.1177/00220345950740060301 Conrad, 2007, Current ceramic materials and systems with clinical recommendations: a systematic review, J Prosthet Dent, 98, 389, 10.1016/S0022-3913(07)60124-3 Bindl, 2002, An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns, Int J Prosthodont, 15, 451 Sorensen, 1998, IPS Empress crown system: three-year clinical trial results, J Calif Dent Assoc, 26, 130, 10.1080/19424396.1998.12221650 Fradeani, 2005, Five-year follow-up with Procera all-ceramic crowns, Quintessence Int, 36, 105 Wolfart, 2005, A preliminary prospective evaluation of all ceramic crown-retained and inlay-retained fixed partial dentures, Int J Prosthodont, 18, 497 Esquivel-Upshaw, 2004, Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs, Int J Prosthodont, 17, 469 McLaren, 2000, Survival of In-Ceram crowns in a private practice: a prospective clinical trial, J Prosthet Dent, 83, 216, 10.1016/S0022-3913(00)80015-3 Fradeani, 2002, Clinical experience with In-Ceram Spinell crowns: 5-year follow-up, Int J Periodontics Restorative Dent, 22, 525 Raigrodski, 2006, The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study, J Prosthet Dent, 96, 237, 10.1016/j.prosdent.2006.08.010 Vult von Steyern, 2005, All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study, J Oral Rehabil, 32, 180, 10.1111/j.1365-2842.2004.01437.x Tinschert, 2000, Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics, J Dent, 28, 529, 10.1016/S0300-5712(00)00030-0 Aboushelib, 2005, Microtensile bond strength of different components of core veneered all-ceramic restorations, Dent Mater, 21, 984, 10.1016/j.dental.2005.03.013 Tan, 2012, The use of slow heating and slow cooling regimens to strengthen porcelain fused to zirconia, J Prosthet Dent, 107, 163, 10.1016/S0022-3913(12)60050-X Komine, 2012, Bonding between layering materials and zirconia frameworks, Jpn Dent Sci Rev, 48, 153, 10.1016/j.jdsr.2012.06.001 Raigrodski, 2012, Survival and complications of zirconia-based fixed dental prostheses: a systematic review, J Prosthet Dent, 107, 170, 10.1016/S0022-3913(12)60051-1 Philipp, 2010, Novel ceria-stabilized tetragonal zirconia/alumina nanocomposite as framework material for posterior fixed dental prostheses: preliminary results of a prospective case series at 1 year of function, Quintessence Int, 41, 313 Roediger, 2010, Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results, Int J Prosthodont, 23, 141 Vigolo, 2012, Evaluation of zirconium-oxide-based ceramic single-unit posterior fixed dental prostheses (FDPs) generated with two CAD/CAM systems compared to porcelain-fused-to-metal single-unit posterior FDPs: a 5-year clinical prospective study, J Prosthodont, 21, 265, 10.1111/j.1532-849X.2011.00825.x Sorrentino, 2012, Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses, Clin Oral Investig, 16, 977, 10.1007/s00784-011-0575-2 Örtorp, 2012, A 5-year retrospective study of survival of zirconia single crowns fitted in a private clinical setting, J Dent, 40, 527, 10.1016/j.jdent.2012.02.011 Kern, 2012, Five-year clinical evaluation of all-ceramic posterior FDPs made of In-Ceram zirconia, Int J Prosthodont, 25, 622 Salido, 2012, Prospective clinical study of zirconia-based posterior four-unit fixed dental prostheses: four-year follow-up, Int J Prosthodont, 25, 403 Pelaez, 2012, A four-year prospective clinical evaluation of zirconia and metal-ceramic posterior fixed dental prostheses, Int J Prosthodont, 25, 451 Rinke, 2013, Prospective evaluation of zirconia posterior fixed partial dentures: 7-year clinical results, Int J Prosthodont, 26, 164, 10.11607/ijp.3229 Scotti, 2007, evaluation of in situ early bacterial colonization on a Y-TZP ceramic: a pilot study, Int J Prosthodont, 20, 419 Salihoglu, 2011, Bacterial adhesion and colonization differences between zirconium oxide and titanium alloys: an in vivo human study, Int J Oral Maxillofac Implants, 26, 101 Lughi, 2010, Low temperature degradation -aging- of zirconia: a critical review of the relevant aspects in dentistry, Dent Mater, 26, 807, 10.1016/j.dental.2010.04.006 Marchack, 2008, Customization of milled zirconia copings for all-ceramic crowns: a clinical report, J Prosthet Dent, 99, 169, 10.1016/S0022-3913(08)00028-0 Beuer, 2009, Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs), Clin Oral Investig, 13, 445, 10.1007/s00784-009-0249-5 Cehreli, 2009, CAD/CAM zirconia vs. slip-cast glass-infiltrated alumina/zirconia all-ceramic crowns: 2-year results of a randomized controlled clinical trial, J Appl Oral Sci, 17, 49, 10.1590/S1678-77572009000100010 Stawarczyk, 2011, Fracture load and failure analysis of zirconia single crowns veneered with pressed and layered ceramics after chewing simulation, Dent Mater J, 30, 554, 10.4012/dmj.2011-028 Preis, 2012, Wear performance of dental ceramics after grinding and polishing treatments, J Mech Behav Biomed Mater, 10, 13, 10.1016/j.jmbbm.2012.03.002