Current ceramic materials and systems with clinical recommendations: A systematic review

Journal of Prosthetic Dentistry - Tập 98 Số 5 - Trang 389-404 - 2007
Heather J. Conrad1,2, Wook‐Jin Seong1,2, Igor J. Pesun3,2
1Assistant Professor, Division of Prosthodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, School of Dentistry, University of Minnesota, Minneapolis, Minn
2University of Manitoba, Winnipeg, Canada
3Associate Professor, Department Head, Department of Restorative Dentistry, Faculty of Dentistry, University of Manitoba, School of Dentistry, University of Minnesota, Minneapolis, Minn

Tóm tắt

Từ khóa


Tài liệu tham khảo

Land, 1903, Porcelain dental art: No. II, Dent Cosmos, 45, 615

McLean, 1965, The reinforcement of dental porcelain with ceramic oxides, Br Dent J, 119, 251

Sjogren, 1999, Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice: a retrospective study, Int J Prosthodont, 12, 122

Piconi, 1999, Zirconia as a ceramic biomaterial, Biomaterials, 20, 1, 10.1016/S0142-9612(98)00010-6

Christel, 1988, Biomechanical compatibility and design of ceramic implants for orthopedic surgery, Ann N Y Acad Sci, 523, 234, 10.1111/j.1749-6632.1988.tb38516.x

Piwowarczyk, 2005, A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System, J Prosthodont, 14, 39, 10.1111/j.1532-849X.2005.00003.x

Raigrodski, 2004, Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature, J Prosthet Dent, 92, 557, 10.1016/j.prosdent.2004.09.015

Raigrodski, 2004, Contemporary all-ceramic fixed partial dentures: a review, Dent Clin North Am, 48, 531, 10.1016/j.cden.2003.12.008

Devigus, 2004, Shading Vita YZ substructures: influence on value and chroma, part I, Int J Comput Dent, 7, 293

Heffernan, 2002, Relative translucency of six all-ceramic systems. Part I: core materials, J Prosthet Dent, 88, 4, 10.1067/mpr.2002.126794

Fischer, 2002, Fracture toughness of dental ceramics: comparison of bending and indentation method, Dent Mater, 18, 12, 10.1016/S0109-5641(01)00005-7

Edelhoff, 2002, Tooth structure removal associated with various preparation designs for posterior teeth, Int J Periodontics Restorative Dent, 22, 241

Aboushelib, 2005, Microtensile bond strength of different components of core veneered all-ceramic restorations, Dent Mater, 21, 984, 10.1016/j.dental.2005.03.013

Fradeani, 2005, Five-year follow-up with Procera all-ceramic crowns, Quintessence Int, 36, 105

Oden, 1998, Five-year clinical evaluation of Procera AllCeram crowns, J Prosthet Dent, 80, 450, 10.1016/S0022-3913(98)70010-1

Odman, 2001, Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study, Int J Prosthodont, 14, 504

Wolfart, 2005, A preliminary prospective evaluation of all-ceramic crown-retained and inlay-retained fixed partial dentures, Int J Prosthodont, 18, 497

Frankenberger, 2000, Leucite-reinforced glass ceramic inlays and onlays after six years: clinical behavior, Oper Dent, 25, 459

Fradeani, 2002, An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study, Quintessence Int, 33, 503

Marquardt, 2006, Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study, Quintessence Int, 37, 253

Esquivel-Upshaw, 2004, Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs, Int J Prosthodont, 17, 469

Bindl, 2002, An up to 5-year clinical evaluation of posterior In-Ceram CAD/CAM core crowns, Int J Prosthodont, 15, 451

McLaren, 2000, Survival of In-Ceram crowns in a private practice: a prospective clinical trial, J Prosthet Dent, 83, 216, 10.1016/S0022-3913(00)80015-3

Vult von Steyern, 2001, Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs, Int J Prosthodont, 14, 379

Olsson, 2003, A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs, Int J Prosthodont, 16, 150

Sorensen, 1998, In-Ceram fixed partial dentures: three-year clinical trial results, J Calif Dent Assoc, 26, 207, 10.1080/19424396.1998.12221659

Fradeani, 2002, Clinical experience with In-Ceram Spinell crowns: 5-year follow-up, Int J Periodontics Restorative Dent, 22, 525

Pallesen, 2000, An 8-year evaluation of sintered ceramic and glass ceramic inlays processed by the Cerec CAD/CAM system, Eur J Oral Sci, 108, 239, 10.1034/j.1600-0722.2000.108003239.x

Otto, 2002, Computer-aided direct ceramic restorations: a 10-year prospective clinical study of Cerec CAD/CAM inlays and onlays, Int J Prosthodont, 15, 122

Malament, 1999, Survival of Dicor glass-ceramic dental restorations over 14 years: Part I. Survival of Dicor complete coverage restorations and effect of internal surface acid etching, tooth position, gender, and age, J Prosthet Dent, 81, 23, 10.1016/S0022-3913(99)70231-3

Kim, 2006, Transverse fracture of brittle bilayers: relevance to failure of all-ceramic dental crowns, J Biomed Mater Res B Appl Biomater, 79, 58, 10.1002/jbm.b.30511

Kosmac, 1999, The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic, Dent Mater, 15, 426, 10.1016/S0109-5641(99)00070-6

Luthardt, 1999, Zirconia-TZP and alumina–advanced technologies for the manufacturing of single crowns, Eur J Prosthodont Restor Dent, 7, 113

Reichel, 2004, Virtual Reality by Cerec inLab Framework, Int J Comput Dent, 7, 85

Kamposiora, 1996, Stress concentration in all-ceramic posterior fixed partial dentures, Quintessence Int, 27, 701

Raigrodski, 2001, The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature, J Prosthet Dent, 86, 520, 10.1067/mpr.2001.120111

Raigrodski, 2006, The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study, J Prosthet Dent, 96, 237, 10.1016/j.prosdent.2006.08.010

Vult von Steyern, 2005, All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study, J Oral Rehabil, 32, 180, 10.1111/j.1365-2842.2004.01437.x

Walton, 2003, An up to 15-year longitudinal study of 515 metal-ceramic FPDs: Part 2. Modes of failure and influence of various clinical characteristics, Int J Prosthodont, 16, 177

Goodacre, 2003, Clinical complications in fixed prosthodontics, J Prosthet Dent, 90, 31, 10.1016/S0022-3913(03)00214-2

Miller, 1977, Framework design in ceramo-metal restorations, Dent Clin North Am, 21, 699, 10.1016/S0011-8532(22)00986-7

Oh, 2000, Strength and microstructure of IPS Empress 2 glass-ceramic after different treatments, Int J Prosthodont, 13, 468

Nakamura, 2002, Fracture resistance of pressable glass-ceramic fixed partial dentures, J Oral Rehabil, 29, 951, 10.1046/j.1365-2842.2002.00929.x

Holand, 2000, A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics, J Biomed Mater Res, 53, 297, 10.1002/1097-4636(2000)53:4<297::AID-JBM3>3.0.CO;2-G

Esquivel-Upshaw, 2001, Resistance to staining, flexural strength, and chemical solubility of core porcelains for all-ceramic crowns, Int J Prosthodont, 14, 284

Tinschert, 2001, Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study, Int J Prosthodont, 14, 231

Raptis, 2006, Optical behavior of current ceramic systems, Int J Periodontics Restorative Dent, 26, 31

Stappert, 2006, Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation, J Am Dent Assoc, 137, 514, 10.14219/jada.archive.2006.0224

Fasbinder, 2002, Restorative material options for CAD/CAM restorations, Compend Contin Educ Dent, 23, 911

Attia, 2004, Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems, J Prosthet Dent, 92, 551, 10.1016/j.prosdent.2004.09.002

Reich, 2004, Generation of functional Cerec 3D occlusal surfaces: a comparison of two production methods relevant in practice, Int J Comput Dent, 7, 229

Bindl, 2003, Fracture load of CAD/CAM-generated slot-inlay FPDs, Int J Prosthodont, 16, 653

Otto, 2004, Computer-aided direct all-ceramic crowns: preliminary 1-year results of a prospective clinical study, Int J Periodontics Restorative Dent, 24, 446, 10.11607/prd.00.0601

Denissen, 2000, Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays, J Prosthet Dent, 84, 506, 10.1067/mpr.2000.110258

Reich, 2004, Clinical performance of large, all-ceramic CAD/CAM-generated restorations after three years: a pilot study, J Am Dent Assoc, 135, 605, 10.14219/jada.archive.2004.0248

Attia, 2004, Fracture strength of all-ceramic crowns luted using two bonding methods, J Prosthet Dent, 91, 247, 10.1016/j.prosdent.2003.12.005

Bindl, 2004, Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years, Eur J Oral Sci, 112, 197, 10.1111/j.1600-0722.2004.00119.x

Reich, 2002, The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns, J Prosthet Dent, 88, 44, 10.1067/mpr.2002.127534

Kurbad, 2006, Multicolored ceramic blocks as an esthetic solution for anterior restorations, Int J Comput Dent, 9, 69

Fritzsche, 2004, Treatment of a single-tooth gap with a Cerec 3D crown on an implant: A case report, Int J Comput Dent, 7, 199

Sevuk, 2002, Copy-milled all-ceramic restorations: case reports, Quintessence Int, 33, 353

Sevuk, 2002, Fabrication of one-piece all-ceramic coronal post and laminate veneer restoration: a clinical report, J Prosthet Dent, 88, 565, 10.1067/mpr.2002.129376

Chai, 2000, Probability of fracture of all-ceramic crowns, Int J Prosthodont, 13, 420

Chang, 2003, Tensile bond strengths of five luting agents to two CAD-CAM restorative materials and enamel, J Prosthet Dent, 90, 18, 10.1016/S0022-3913(03)00217-8

Malament, 1999, Survival of Dicor glass-ceramic dental restorations over 14 years. Part II: effect of thickness of Dicor material and design of tooth preparation, J Prosthet Dent, 81, 662, 10.1016/S0022-3913(99)70104-6

Haselton, 2000, Clinical assessment of high-strength all-ceramic crowns, J Prosthet Dent, 83, 396, 10.1016/S0022-3913(00)70033-3

Sundh, 2004, A comparison of fracture strength of yttrium-oxide-partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics, J Oral Rehabil, 31, 682, 10.1111/j.1365-2842.2004.01284.x

Xiao-ping, 2002, Strength and fracture toughness of MgO-modified glass infiltrated alumina for CAD/CAM, Dent Mater, 18, 216, 10.1016/S0109-5641(01)00026-4

Heffernan, 2002, Relative translucency of six all-ceramic systems. Part II: core and veneer materials, J Prosthet Dent, 88, 10, 10.1067/mpr.2002.126795

Magne, 1997, Esthetic improvements and in vitro testing of In-Ceram Alumina and Spinell ceramic, Int J Prosthodont, 10, 459

Dozic, 2003, The influence of porcelain layer thickness on the final shade of ceramic restorations, J Prosthet Dent, 90, 563, 10.1016/S0022-3913(03)00517-1

De Jager, 2005, The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns, Dent Mater, 21, 242, 10.1016/j.dental.2004.03.013

van der Zel, 2001, The CICERO system for CAD/CAM fabrication of full-ceramic crowns, J Prosthet Dent, 85, 261, 10.1067/mpr.2001.114399

Bindl, 2005, Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations, J Oral Rehabil, 32, 441, 10.1111/j.1365-2842.2005.01446.x

Andersson, 1993, A new all-ceramic crown. A dense-sintered, high-purity alumina coping with porcelain, Acta Odontol Scand, 51, 59, 10.3109/00016359309041149

May, 1998, Precision of fit: the Procera AllCeram crown, J Prosthet Dent, 80, 394, 10.1016/S0022-3913(98)70002-2

Garvie, 1975, Ceramic steel?, Nature, 258, 703, 10.1038/258703a0

Garvie, 1972, Phase analysis in zirconia systems, J Am Ceram Soc, 55, 303, 10.1111/j.1151-2916.1972.tb11290.x

Kohal, 2004, A zirconia implant-crown system: a case report, Int J Periodontics Restorative Dent, 24, 147

Sundh, 2005, Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing, Dent Mater, 21, 476, 10.1016/j.dental.2004.07.013

Luthardt, 2002, Reliability and properties of ground Y-TZP-zirconia ceramics, J Dent Res, 81, 487, 10.1177/154405910208100711

Luthardt, 2004, CAD/CAM-machining effects on Y-TZP zirconia, Dent Mater, 20, 655, 10.1016/j.dental.2003.08.007

Tinschert, 2001, Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system, Oper Dent, 26, 367

Guazzato, 2004, Strength, reliability and mode of fracture of bilayered porcelain/zirconia (Y-TZP) dental ceramics, Biomaterials, 25, 5045, 10.1016/j.biomaterials.2004.02.036

Addi, 2002, Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro, J Dent, 30, 53, 10.1016/S0300-5712(01)00059-8

Coli, 2004, Fit of a new pressure-sintered zirconium dioxide coping, Int J Prosthodont, 17, 59

Butz, 2005, Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation, J Oral Rehabil, 32, 838, 10.1111/j.1365-2842.2005.01515.x

Henriksson, 2003, Evaluation of custom-made procera ceramic abutments for single-implant tooth replacement: a prospective 1-year follow-up study, Int J Prosthodont, 16, 626

Priest, 2005, Virtual-designed and computer-milled implant abutments, J Oral Maxillofac Surg, 63, 22, 10.1016/j.joms.2005.05.158

Heydecke, 2002, Evolution and use of aluminum oxide single-tooth implant abutments: a short review and presentation of two cases, Int J Prosthodont, 15, 488

Suarez, 2004, Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs, Int J Prosthodont, 17, 35

Probster, 1996, Four year clinical study of glass-infiltrated, sintered alumina crowns, J Oral Rehabil, 23, 147, 10.1111/j.1365-2842.1996.tb01225.x

Scurria, 1998, Meta-analysis of fixed partial denture survival: prostheses and abutments, J Prosthet Dent, 79, 459, 10.1016/S0022-3913(98)70162-3

Esquivel-Upshaw, 2000, Ceramic design concepts based on stress distribution analysis, Compend Contin Educ Dent, 21, 649

Scherrer, 1993, The fracture resistance of all-ceramic crowns on supporting structures with different elastic moduli, Int J Prosthodont, 6, 462

Meyer, 2003, Ceramic inlays and onlays: clinical procedures for predictable results, J Esthet Restor Dent, 15, 338, 10.1111/j.1708-8240.2003.tb00307.x

Wen, 1999, Comparative mechanical property characterization of 3 all-ceramic core materials, Int J Prosthodont, 12, 534

Lohbauer, 2002, Lifetime prediction of CAD/CAM dental ceramics, J Biomed Mater Res, 63, 780, 10.1002/jbm.10468

Seghi, 1995, Relative fracture toughness and hardness of new dental ceramics, J Prosthet Dent, 74, 145, 10.1016/S0022-3913(05)80177-5

Hwang, 2001, Fracture strength of copy-milled and conventional In-Ceram crowns, J Oral Rehabil, 28, 678, 10.1046/j.1365-2842.2001.00731.x

Guazzato, 2002, Mechanical properties of In-Ceram Alumina and In-Ceram Zirconia, Int J Prosthodont, 15, 339

Chong, 2002, Flexural strength of In-Ceram alumina and In-Ceram zirconia core materials, Int J Prosthodont, 15, 183

Zeng, 1998, Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains, Int J Prosthodont, 11, 183

Wakabayashi, 2000, Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness, J Dent Res, 79, 1398, 10.1177/00220345000790060801

Proos, 2003, Influence of core thickness on a restored crown of a first premolar using finite element analysis, Int J Prosthodont, 16, 474

Studart, 2007, Mechanical and fracture behavior of veneer-framework composites for all-ceramic dental bridges, Dent Mater, 23, 115, 10.1016/j.dental.2005.12.009

Taskonak, 2005, Residual stresses in bilayer dental ceramics, Biomaterials, 26, 3235, 10.1016/j.biomaterials.2004.08.025

Studart, 2007, Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges, Dent Mater, 23, 177, 10.1016/j.dental.2006.01.011

Oh, 2002, Influence of connector design on fracture probability of ceramic fixed-partial dentures, J Dent Res, 81, 623, 10.1177/154405910208100909

Oh, 2002, Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures, J Prosthet Dent, 87, 536, 10.1067/mpr.2002.123850

Oilo, 2003, All-ceramic crowns and preparation characteristics: a mathematic approach, Int J Prosthodont, 16, 301

Pospiech, 1996, All-ceramic resin-bonded bridges. A 3-dimensional finite-element analysis study, Eur J Oral Sci, 104, 390, 10.1111/j.1600-0722.1996.tb00097.x

DeLong, 1983, Development of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control, J Dent Res, 62, 32, 10.1177/00220345830620010801

Strub, 1998, Fracture strength of 5 different all-ceramic crown systems, Int J Prosthodont, 11, 602

Christensen, 1966, Marginal fit of gold inlay castings, J Prosthet Dent, 16, 297, 10.1016/0022-3913(66)90082-5

McLean, 1971, The estimation of cement film thickness by an in vivo technique, Br Dent J, 131, 107, 10.1038/sj.bdj.4802708

Holmes, 1989, Considerations in measurement of marginal fit, J Prosthet Dent, 62, 405, 10.1016/0022-3913(89)90170-4

Knoernschild, 2000, Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures, J Prosthet Dent, 84, 492, 10.1067/mpr.2000.110262

Martin, 2000, Interface dimensions of CEREC-2 MOD inlays, Dent Mater, 16, 68, 10.1016/S0109-5641(99)00089-5

Reich, 2005, Clinical fit of all-ceramic three-unit fixed partial dentures generated with three different CAD/CAM systems, Eur J Oral Sci, 113, 174, 10.1111/j.1600-0722.2004.00197.x

Lin, 1998, The effect of tooth preparation form on the fit of Procera copings, Int J Prosthodont, 11, 580

Molin, 1993, The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study, Acta Odontol Scand, 51, 201, 10.3109/00016359309040568

Luthardt, 2004, An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing, Int J Prosthodont, 17, 680

Nakamura, 2003, Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns, Int J Prosthodont, 16, 244

Sato, 2002, Relation between cavity design and marginal adaptation in a machine-milled ceramic restorative system, J Oral Rehabil, 29, 24, 10.1046/j.1365-2842.2002.00798.x

Mou, 2002, Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns, J Prosthet Dent, 87, 248, 10.1067/mpr.2002.122011

Balkaya, 2005, Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems, J Prosthet Dent, 93, 346, 10.1016/j.prosdent.2005.02.003

Reich, 2005, A comparative study of two CEREC software systems in evaluating manufacturing time and accuracy of restorations, Gen Dent, 53, 195

Boening, 2000, Clinical fit of Procera AllCeram crowns, J Prosthet Dent, 84, 419, 10.1067/mpr.2000.109125

Fleming, 2003, The effect of cement type and mixing on the bi-axial fracture strength of cemented aluminous core porcelain discs, Dent Mater, 19, 69, 10.1016/S0109-5641(02)00006-4

Knobloch, 2000, Fracture toughness of resin-based luting cements, J Prosthet Dent, 83, 204, 10.1016/S0022-3913(00)80013-X

Diaz-Arnold, 1999, Current status of luting agents for fixed prosthodontics, J Prosthet Dent, 81, 135, 10.1016/S0022-3913(99)70240-4

Chen, 1998, Effect of different etching periods on the bond strength of a composite resin to a machinable porcelain, J Dent, 26, 53, 10.1016/S0300-5712(96)00078-4

Kamada, 1998, Effect of ceramic surface treatments on the bond of four resin luting agents to a ceramic material, J Prosthet Dent, 79, 508, 10.1016/S0022-3913(98)70170-2

Ahmad, 2002, Restitution of maxillary anterior aesthetics with all-ceramic components, Int Dent J, 52, 47, 10.1111/j.1875-595X.2002.tb00597.x

Jedynakiewicz, 2001, The effect of surface coating on the bond strength of machinable ceramics, Biomaterials, 22, 749, 10.1016/S0142-9612(00)00294-5

Kern, 1994, Sandblasting and silica coating of a glass-infiltrated alumina ceramic: volume loss, morphology, and changes in the surface composition, J Prosthet Dent, 71, 453, 10.1016/0022-3913(94)90182-1

Bindl, 2005, Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry, Int J Prosthodont, 18, 219

Scherrer, 1996, Fracture resistance of human enamel and three all-ceramic crown systems on extracted teeth, Int J Prosthodont, 9, 580

Bindl, 2006, Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns, Dent Mater, 22, 29, 10.1016/j.dental.2005.02.007

Attia, 2006, Fracture load of composite resin and feldspathic all-ceramic CAD/CAM crowns, J Prosthet Dent, 95, 117, 10.1016/j.prosdent.2005.11.014

Albert, 2004, Marginal adaptation and microleakage of Procera AllCeram crowns with four cements, Int J Prosthodont, 17, 529

Federlin, 2005, Partial ceramic crowns. Influence of preparation design and luting material on margin integrity–a scanning electron microscopic study, Clin Oral Investig, 9, 8, 10.1007/s00784-004-0276-1

Sjogren, 2004, A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite, Int J Prosthodont, 17, 241

Sjogren, 1998, A 5-year clinical evaluation of ceramic inlays (Cerec) cemented with a dual-cured or chemically cured resin composite luting agent, Acta Odontol Scand, 56, 263, 10.1080/000163598428428

Hasegawa, 1991, Hardening of dual-cured cements under composite resin inlays, J Prosthet Dent, 66, 187, 10.1016/S0022-3913(05)80046-0

Peutzfeldt, 1995, Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing, Acta Odontol Scand, 53, 29, 10.3109/00016359509005941

Lee, 2001, Thermal analysis on the cure speed of dual cured resin cements under porcelain inlays, J Oral Rehabil, 28, 186, 10.1046/j.1365-2842.2001.00639.x

Tanoue, 2003, Properties of dual-curable luting composites polymerized with single and dual curing modes, J Oral Rehabil, 30, 1015, 10.1046/j.1365-2842.2003.01074.x

Shimura, 2005, Influence of curing method and storage condition on microhardness of dual-cure resin cements, Dent Mater J, 24, 70, 10.4012/dmj.24.70

Peumans, 2000, Porcelain veneers: a review of the literature, J Dent, 28, 163, 10.1016/S0300-5712(99)00066-4

Federlin, 2004, Partial ceramic crowns: influence of preparation design and luting material on internal adaptation, Oper Dent, 29, 560

Ferrari, 2001, Bonding of all-porcelain crowns: structural characteristics of the substrate, Dent Mater, 17, 156, 10.1016/S0109-5641(00)00059-2

Ibarra, 2007, Microleakage of porcelain veneer restorations bonded to enamel and dentin with a new self-adhesive resin-based dental cement, Dent Mater, 23, 218, 10.1016/j.dental.2006.01.013

Awliya, 1998, Shear bond strength of a resin cement to densely sintered high-purity alumina with various surface conditions, Acta Odontol Scand, 56, 9, 10.1080/000163598422992

Kern, 1998, Bonding to alumina ceramic in restorative dentistry: clinical results over up to 5 years, J Dent, 26, 245, 10.1016/S0300-5712(97)00009-2

Derand, 2000, Bond strength of luting cements to zirconium oxide ceramics, Int J Prosthodont, 13, 131

Kern, 1998, Bonding to zirconia ceramic: adhesion methods and their durability, Dent Mater, 14, 64, 10.1016/S0109-5641(98)00011-6

Ernst, 2005, In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents, J Prosthet Dent, 93, 551, 10.1016/j.prosdent.2005.04.011

Zhang, 2006, Damage accumulation and fatigue life of particle-abraded ceramics, Int J Prosthodont, 19, 442

Zhang, 2004, Effect of sandblasting on the long-term performance of dental ceramics, J Biomed Mater Res B Appl Biomater, 71, 381, 10.1002/jbm.b.30097

Palacios, 2006, Retention of zirconium oxide ceramic crowns with three types of cement, J Prosthet Dent, 96, 104, 10.1016/j.prosdent.2006.06.001

Herrguth, 2005, The aesthetics of all-ceramic veneered and monolithic CAD/CAM crowns, J Oral Rehabil, 32, 747, 10.1111/j.1365-2842.2005.01498.x

Douglas, 1999, Predicting porcelain thickness required for dental shade matches, J Prosthet Dent, 82, 143, 10.1016/S0022-3913(99)70147-2

Vichi, 2000, Influence of ceramic and cement thickness on the masking of various types of opaque posts, J Prosthet Dent, 83, 412, 10.1016/S0022-3913(00)70035-7