Juan F, Santiago, Adolfo et al (2011) Design and manufacturing of a custom skull implant. Am J Eng Appl Sci 4(1):169–174
Joffe JM, Nicoll SR, Richards R, Linney AD, Harris M (1999) Validation of computer-assisted manufacture of titanium plates for cranioplasty. Int J Oral Maxillofac Surg 28(309–313):1999
Chacon E, Jose FH, Sandra PC, Fabricio CZ et al (2009) Cranial vault reconstruction using computer-designed Polyetheretherketone (PEEK) implant: case report. Cir Ciruj 77(437–440):2009
Origitano TC, Ricardo I, Louis BS (1995) Reconstructing complex cranial defects with a preformed cranial prosthesis. Skull Base Surg 5(5):109–116
Artico M, Ferrante L, Pastore FS, Ramundo EO, Cantarelli D et al (2003) Bone autografting of the calvaria and craniofacial skeleton: Historical background, surgical results in a series of 15 patients, and review of the literature. Surg Neurol 60:71–79
Malis L (1989) Titanium mesh and acrylic cranioplasty. Neurosurg 25:351–355
Yanai MDA (1991) Resin sealant: a new method of methyl methacrylate cranioplasty. Technical note. J Neurosurg 75:328–330
Gronet PM, Waskewicz GA, Richardson C (2003) Preformed acrylic cranial implants using fused deposition modeling: a clinical report. J Prosthet Dent 90:429–433
Joffe JM, Mcdermott PJC, Linney AD, Mosse CA, Harris M (1992) Computer-generated titanium cranioplasty: report of a new technique for repairing skull defects. Br J Neurosurg 6:343–350
Santoni-Rugiu P (1969) Repair of skull defects by outer table osteoperiosteal free grafts. Plast Reconstr Surg 43:157–161
Kulali A, Kayaale S (1991) Single-table autogenous calvarial grafting for cranioplasty. J Craniomaxillofac Surg 19:208–211
Psillakis JM, Nocchi VL, Zanini SA (1979) Repair of large defect of frontal bone with free graft of outer table of parietal bones. Plast Reconstr Surg 64:827–830
Prolo DJ, Oklund S (1984) Composite autogeneic human cranioplasty: frozen skull supplemented with fresh iliac corticocancellous bone. Neurosurgery 15:846–851
Osawa M, Hara H, Ichinose Y, Koyama T, Kobayashi S et al (1990) Cranioplasty with a frozen and autoclaved bone flap. Acta Neurochir 102:38–41
Hollier LH, Stal S (2004) The use of hydroxyapatite cements in craniofacial surgery. Clin Plast Surg 31:423–428
Koppel DA, Moos KF, Walker FS (1999) Skull reconstruction with a two-part interlocking custom made titanium plate. Br J Oral Maxillofac Surg 37:70–72
Kuttenberger JJ, Hardt N (2001) Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems. J Craniomaxillofac Surg 29:75–81
Solaro P, Pierangeli E, Pizzoni C, Boffi P, Scalese G, Di Lorenzo N, Pirillo V (2008) From computerized tomography data processing to rapid manufacturing of custom-made prostheses for cranioplasty: case report. J Neurosurg Sci 52(4):113–116
Anusavice JK (2003) Phillip’s science of dental materials (ch-22), 11th edn. Elsevier, St. Louis, p 733