Contrast echocardiography

Current Problems in Cardiology - Tập 27 Số 11 - Trang 454-519 - 2002
Jonathan R. Lindner1
1Cardiovascular Division at the University of Virginia Medical Center, Charlottesville, Virginia, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

de Jong, 2000, Optical imaging of contrast agent microbubbles in an ultrasound field with a 100-MHx camera, Ultrasound Med Biol, 26, 487, 10.1016/S0301-5629(99)00159-3

Dayton, 1999, Optical and acoustical observations of the effects of ultrasound on contrast agents, IEEE Trans Ultrason Ferroelect Freq Contr, 46, 220, 10.1109/58.741536

Gramiak, 1968, Echocardiography of the aortic root, Invest Radiol, 3, 356, 10.1097/00004424-196809000-00011

Armstrong, 1982, Assessment of myocardial perfusion abnormalities with contrast-enhanced two-dimensional echocardiography, Circulation, 66, 166, 10.1161/01.CIR.66.1.166

Tei, 1983, Myocardial contrast echocardiography: a reproducible technique for myocardial opacification for identifying regional perfusion deficits, Circulation, 67, 585, 10.1161/01.CIR.67.3.585

Kemper, 1983, Hydrogen peroxide contrast enhanced two-dimensional echocardiography: real-time in vivo delineation of regional myocardial perfusion, Circulation, 68, 603, 10.1161/01.CIR.68.3.603

Feinstein, 1984, Two-dimensional contrast echocardiography: I, in vitro development and quantitative analysis of echo contrast agents, J Am Coll Cardiol, 3, 14, 10.1016/S0735-1097(84)80424-6

Kassab, 1994, Topology and dimensions of pig coronary capillary network, Am J Physiol Heart Circ Physiol, 267, H319, 10.1152/ajpheart.1994.267.1.H319

Ono, 1986, Scanning electron microscopic studies on microvascular architecture of human coronary vessels by corrosion casts: normal and focal necrosis, Scanning Electron Microsc, 1, 263

Desjardins, 1990, Heparinase treatment suggests a role for the endothelial cell glycocalyx in regulation of capillary hematocrit, Am J Physiol, 258, H647

Lindner, 1998, Albumin microbubble persistence during myocardial contrast echocardiography is associated with microvascular endothelial glycocalyx damage, Circulation, 98, 2187, 10.1161/01.CIR.98.20.2187

Gillam, 1985, Functional and pathologic effects of multiple echocardiographic contrast injections on the myocardium, brain and kidney, J Am Coll Cardiol, 6, 687, 10.1016/S0735-1097(85)80132-7

Moore, 1986, Myocardial contrast echocardiography in humans: I, safety a comparison with routine coronary arteriography, J Am Coll Cardiol, 8, 1066, 10.1016/S0735-1097(86)80383-7

Lange, 1987, Effects of intracoronary: injection of sonicated microbubbles on left ventricular contractility, Am J Cardiol, 60, 166, 10.1016/0002-9149(87)91006-X

Keller, 1988, Myocardial contrast echocardiography without significant hemodynamic effects or reactive hyperemia: a major advantage in the imaging of myocardial perfusion, J Am Coll Cardiol, 12, 1039, 10.1016/0735-1097(88)90474-3

Christiansen, 1994, Physical and biochemical characterization of Albunex, a new ultrasound contrast agent consisting of air-filled albumin microspheres suspended in a solution of human serum albumin, Biotechnol Appl Biochem, 19, 307, 10.1111/j.1470-8744.1994.tb00300.x

Keller, 1989, Albunex: a safe and effective commercially produced agent for myocardial contrast echocardiography, J Am Soc Echocardiogr, 2, 48, 10.1016/S0894-7317(89)80028-8

Ten Cate, 1993, Intracoronary Albunex: its effects on coronary hemodynamics, function, and coronary sinus flow in humans, Circulation, 88, 2123, 10.1161/01.CIR.88.5.2123

Hellebust, 1993, Biochemical characterization of air-filled albumin microspheres, Biotechnol Appl Biochem, 18, 227, 10.1111/j.1470-8744.1993.tb00269.x

Forsberg, 2001, Physics of contrast microbubbles, 15

DeJong, 1994, Higher harmonics of vibrating gas filled microspheres, Ultrasonics, 32, 455, 10.1016/0041-624X(94)90065-5

Lindner, 1997, Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex, Am J Cardiol, 79, 1657, 10.1016/S0002-9149(97)00217-8

Wible, 1996, Inhaled gases affect the ultrasound contrast produced by Albunex in anesthetized dogs, J Am Soc Echocardiogr, 9, 442, 10.1016/S0894-7317(96)90115-7

Rovai, 1993, Intracoronary air-filled albumin microspheres for myocardial blood flow measurement, J Am Coll Cardiol, 22, 2014, 10.1016/0735-1097(93)90792-Y

Villanueva, 1996, Coronary reserve abnormalities in the infarcted myocardium: assessment of myocardial viability immediately versus late after reflow by contrast echocardiography, Circulation, 94, 748, 10.1161/01.CIR.94.4.748

Lindner, 1997, Changes in myocardial blood volume with graded coronary stenosis, Am J Physiol, 272, H567

Ismail, 1995, Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography, Circulation, 91, 821, 10.1161/01.CIR.91.3.821

Epstein, 1950, On the stability of gas bubbles in liquid-gas solutions, J Chem Phys, 18, 1505, 10.1063/1.1747520

Kabalnov, 1998, Dissolution of multicomponent microbubbles in the bloodstream: I, theory, Ultrasound Med Biol, 24, 739, 10.1016/S0301-5629(98)00034-9

Grayburn, 1995, Peripheral intravenous myocardial contrast echocardiography using a 2% dodecafluoropentane emulsion: identification of myocardial risk area and infarct size in the canine model of ischemia, J Am Coll Cardiol, 26, 1340, 10.1016/0735-1097(95)00306-1

Beppu, 1997, Prolonged myocardial contrast echocardiography via peripheral venous administration of QW3600 injection (Echogen): its efficacy and side effects, J Am Soc Echocardiogr, 10, 11, 10.1016/S0894-7317(97)80028-4

Jayaweera, 1994, In-vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography: comparison with radiolabeled red blood cells, Circ Res, 74, 1157, 10.1161/01.RES.74.6.1157

Lindner, 2002, Microvascular theology of Definity microbubbles following intra-arterial and intravenous administration, J Am Soc Echocardiogr, 15, 396, 10.1067/mje.2002.117290

Keller, 1989, The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography, Circ Res, 65, 458, 10.1161/01.RES.65.2.458

Skyba, 1996, Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection, J Am Coll Cardiol, 28, 1292, 10.1016/S0735-1097(96)00328-2

Villanueva, 1997, Albumin microbubble adherence to human coronary endothelium: implications for assessment of endothelial function using myocardial contrast echocardiography, J Am Coll Cardiol, 30, 689, 10.1016/S0735-1097(97)00197-6

Fisher, 2002, Influence of surface charge on capillary transit and myocardial contrast enhancement, J Am Coll Cardiol, 40, 811, 10.1016/S0735-1097(02)02038-7

Klibanov, 1990, Amphipathic polyethyleneglycols effectively prolong the circulation time of liposomes, FEBS Lett, 268, 235, 10.1016/0014-5793(90)81016-H

Torchilin, 1994, Poly(ethylene glycol) on the liposome surface: on the mechanism of polymer-coated liposome longevity, Biochim Biophys Acta, 1195, 11, 10.1016/0005-2736(94)90003-5

Frinking, 1999, Scattering properties of encapsulated gas bubbles at high ultrasound pressures, J Acoust Soc Am, 105, 1989, 10.1121/1.426732

Medwin, 1977, Counting bubbles acoustically: a review, Ultrasonics, 15, 7, 10.1016/0041-624X(77)90005-1

DeJong, 1992, Absorption and scatter of encapsulated gas filled microspheres: theoretical considerations and some measurements, Ultrasonics, 30, 95, 10.1016/0041-624X(92)90041-J

Leong-Poi, 2002, Influence of microbubble shell properties on ultrasound signal: implications for low-power perfusion imaging, J Am Soc Echocardiogr, 15, 1269, 10.1067/mje.2002.124516

Sboros, 2000, An in vitro comparison of ultrasonic contrast agents with varying air levels, Ultrasound Med Biol, 26, 807, 10.1016/S0301-5629(00)00215-5

L Hoff, PC Sontum, B Hoff, Acoustic properties of shell-encapsulated, gas-filled ultrasound contrast agents (Proceedings of the IEEE Ultrasonics Symposium; 1996 Nov 3-6; San Antonio, Texas 1441-4).

Miller, 1981, Ultrasonic detection of resonant cavitation bubbles in a flow tube by their second harmonic emission, Ultrasonics, 19, 217, 10.1016/0041-624X(81)90006-8

Burns, 1996, Harmonic imaging: principles and preliminary results, Clin Radiol, 51, 50

Firschke, 1997, Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second generation echocardiographic contrast agent, Circulation, 96, 959

Porter, 1996, Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin, J Am Coll Cardiol, 27, 1497, 10.1016/0735-1097(96)00017-4

Lindner, 1998, Myocardial perfusion characteristics and hemodynamic profile of MRX-115, a venous echocardiographic contrast agent, during acute myocardial infarction, J Am Soc Echocardiogr, 11, 36, 10.1016/S0894-7317(98)70118-X

Thomas, 1998, Tissue harmonic imaging: why does it work?, J Am Soc Echocardiogr, 11, 803, 10.1016/S0894-7317(98)70055-0

Chomas, 2001, Mechanisms of contrast agent destruction, IEEE Trans Ultrason Ferroelect Freq Contr, 48, 232, 10.1109/58.896136

Sklenar, 1992, A computer-aided approach for the quantitation of regional left ventricular function using two-dimensional echocardiography, J Am Soc Echocardiogr, 5, 33, 10.1016/S0894-7317(14)80100-4

Becher, 2000

Hope Simpson, 1999, Pulse inversion Doppler: a new method for detecting non-linear echoes from microbubble contrast agents, IEEE Trans Ultrason Ferroelect Freq Contr, 46, 372, 10.1109/58.753026

Masugata, 2001, Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves, J Am Coll Cardiol, 37, 262, 10.1016/S0735-1097(00)01046-9

Mor-Avi, 2001, Combined assessment of myocardial perfusion and regional left ventricular function by analysis of contrast-enhanced power modulation images, Circulation, 104, 352, 10.1161/01.CIR.104.3.352

Reilly, 2000, Contrast echocardiography clarifies uninterpretable wall motion in intensive care unit patients, J Am Coll Cardiol, 35, 485, 10.1016/S0735-1097(99)00558-6

Crouse, 1993, Opacification and border delineation improvement in patients with suboptimal border definition in routine echocardiography: results of the phase III Albunex multicenter trial, J Am Coll Cardiol, 22, 1494, 10.1016/0735-1097(93)90562-F

Rainbird, 2001, Contrast dobutamine stress echocardiography: clinical practice assessment: in 300 consecutive patients, J Am Soc Echocardiogr, 14, 378, 10.1067/mje.2001.111264

Hundley, 1998, Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging, J Am Coll Cardiol, 32, 1426, 10.1016/S0735-1097(98)00409-4

Yu, 2000, Feasibility and accuracy of left ventricular volumes and ejection fraction determination by fundamental, tissue harmonic, and intravenous contrast imaging in difficult-to-image patients, J Am Soc Echocardiogr, 13, 216, 10.1067/mje.2000.103597

Yong, 2002, Diagnostic accuracy and cost-effectiveness of contrast echocardiography on evaluation of cardiac function in technically very difficult patients in the intensive care unit, Am J Cardiol, 89, 711, 10.1016/S0002-9149(01)02344-X

Caiani, 2001, Objective assessment of left ventricular wall motion based on contrast enhanced echocardiographic images, J Am Coll Cardiol, 37, 410A

Shaw, 1998, Use of an intravenous contrast agent (Optison) to enhance echocardiography: efficacy and cost implications, Am J Managed Care, 4, SP169

Thanigaraj, 2001, Use of contrast for image enhancement during stress echocardiography is cost-effective and reduces additional diagnostic testing, Am J Cardiol, 87, 1430, 10.1016/S0002-9149(01)01573-9

Skyba, 1994, Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast: implications for venous injection, Circulation, 90, 1513, 10.1161/01.CIR.90.3.1513

Kassab, 1994, Morphometry of the pig coronary venous system, Am J Physiol, 267, H2100

Lindner, 2000, Assessment of resting perfusion with myocardial contrast echocardiography. Theoretical and practical considerations, Am Heart J, 139, 231, 10.1016/S0002-8703(00)90231-X

Wei, 1997, Interaction between microbubbles and ultrasound: in vitro and in vivo observations, J Am Coll Cardiol, 29, 1081, 10.1016/S0735-1097(97)00029-6

Wei, 1998, Quantification of myocardial blood flow with ultrasound induced destruction of microbubbles administered as a constant venous infusion, Circulation, 97, 473, 10.1161/01.CIR.97.5.473

Reimer, 1979, The ″wavefront phenomenon” of myocardial ischemic cell death: II, transmural progression of necrosis within the framework of ischemic bed size (myocardium at risk) and collateral flow, Lab Invest, 40, 633

Kaul, 1987, Effects of selectively altering collateral driving pressure on regional perfusion and function in occluded coronary bed in the dog, Circ Res, 61, 77, 10.1161/01.RES.61.1.77

Piek, 1988, Collateral blood supply to the myocardium at risk in human myocardial infarction: a quantitative postmortem assessment, J Am Coll Cardiol, 11, 1290, 10.1016/0735-1097(88)90294-X

Levin, 1974, Pathways and functional significance of the coronary collateral circulation, Circulation, 50, 831, 10.1161/01.CIR.50.4.831

Kaul, 1986, Contrast echocardiography in acute myocardial ischemia: III, an in-vivo comparison of the extent of abnormal wall motion with the ″area at risk” for necrosis, J Am Coll Cardiol, 7, 383, 10.1016/S0735-1097(86)80509-5

Kaul, 1984, Contrast echocardiography in acute myocardial ischemia: I, in vivo determination of total left ventricular ″area at risk”, J Am Coll Cardiol, 4, 1272, 10.1016/S0735-1097(84)80149-7

Kaul, 1985, Contrast echocardiography in acnte myocardial ischemia: II, the effect of site of injection of contrast agent on the estimation of area at risk for necrosis after coronary occlusion, J Am Coll Cardiol, 6, 825, 10.1016/S0735-1097(85)80490-3

Firschke, 1997, Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: potential application in the cardiac catheterization laboratory, J Am Coll Cardiol, 29, 207, 10.1016/S0735-1097(96)00426-3

Villanueva, 1993, Assessment of risk area during coronary occlusion and infarct size after reperfusion with myocardial contrast echocardiography using left and right atrial injections of contrast, Circulation, 88, 596, 10.1161/01.CIR.88.2.596

Leistad, 2001, Quantitative assessment of myocardial perfusion during graded coronary artery stenosis by intraveneous myocardial contrast echocardiography, J Am Coll Cardiol, 37, 624, 10.1016/S0735-1097(00)01127-X

Dittrich, 1995, Myocardial contrast echocardiography in experimental coronary artery occlusion with a new intravenously administered contrast agent, J Am Soc Echocardiogr, 8, 465, 10.1016/S0894-7317(05)80333-5

Schaper, 1979, Experimental coronary artery occlusion 1: measurement of infarct size, Basic Res Cardiol, 74, 46, 10.1007/BF01907684

Sabia, 1992, Functional significance of collateral blood flow in patients with recent acute myocardial infarction: a study using myocardial contrast echocardiography, Circulation, 85, 2080, 10.1161/01.CIR.85.6.2080

Maruoka, 1986, Relations between collateral flow and tissue salvage in the risk area after acute coronary occlusion in dogs: a topographical analysis, Br J Exp Pathol, 67, 33

Coggins, 2001, Noninvasive prediction of ultimate infarct size at the time of acute coronary occlusion based on the extent and magnitude of collateral-derived myocardial blood flow, Circulation, 104, 2471, 10.1161/hc4501.098954

Lafitte, 2002, Contrast echocardiography can assess risk area and infarct size during coronary occlusion and reperfusion: experimental validation, J Am Coll Cardiol, 39, 1546, 10.1016/S0735-1097(02)01771-0

Gewirtz, 1994, Positron emission tomographic measurements of absolute regional myocardial blood flow permits identification of nonviable myocardium in patients with chronic myocardial infarction, J Am Coll Cardiol, 23, 851, 10.1016/0735-1097(94)90629-7

Califf, 1988, Failure of simple clinical measurements to predict perfusion status after intravenous thrombolysis, Ann Intern Med, 108, 658, 10.7326/0003-4819-108-5-658

Ellis, 1994, Randomized comparison of rescue angioplasty with conservative management of patients with early failure of thrombolysis for acute anterior myocardial infarction, Circulation, 90, 2280, 10.1161/01.CIR.90.5.2280

Ito, 1996, Myocardial perfusion patterns related to thrombolysis in myocardial infarction perfusion grades after coronary angioplasty in patinets with acute anterior wall myocardial infarction, Circulation, 93, 1993, 10.1161/01.CIR.93.11.1993

Iwakura, 1996, Alternation in the coronary blood flow velocity pattern in patients with no reflow and reperfused acute myocardial infarction, Circulation, 94, 1269, 10.1161/01.CIR.94.6.1269

Kamp, 2001, Serial evaluation of perfusion defects in patients with a first acute myocardial infarction referred for primary PTCA using intravenous myocardial contrast echocardiography, Eur Heart J, 22, 1485, 10.1053/euhj.2001.2604

Porter, 1998, The clinical implications of no reflow demonstrated with intravenous perfluorocarbon containing microbubbles following restoration of thrombolysis in myocardial infarction (TIMI) 3 flow in patients with acute myocardial infarction, Am J Cardiol, 82, 1173, 10.1016/S0002-9149(98)00597-9

Ito, 1996, Clinical implications of the ″no reflow” phenomenon: a predictor of complications and left ventricular remodeling in reperfused anterior wall myocardial infarction, Circulation, 93, 223, 10.1161/01.CIR.93.2.223

Sakuma, 1998, Prediction of short- and intermediate-term prognoses of patients with acute myocardial infarction using myocardial 59 contrast echocardiography one day after recanalization, J Am Coll Cardiol, 32, 890, 10.1016/S0735-1097(98)00342-8

Senior, 1999, Myocardial viability on echocardiography predicts long-term survival after revascularization in patients with congestive heart failure, J Am Coll Cardiol, 33, 1848, 10.1016/S0735-1097(99)00102-3

Afridi, 1998, Myocardial viability during dobutamine echocardiography predicts survival in patients with coronary artery disease and severe left ventricular dysfunction, J Am Coll Cardiol, 32, 921, 10.1016/S0735-1097(98)00321-0

Pasquet, 1999, Prognostic value of myocardial ischemia and viability in patients with chronic left ventricular ischemic dysfunction, Circulation, 100, 141, 10.1161/01.CIR.100.2.141

Kloner, 1974, The ″no-reflow” phenomenon after temporary coronary occlusion in the dog, J Clin Invest, 54, 1496, 10.1172/JCI107898

White, 1978, Regional redistribution of myocardial blood flow after coronary occlusion and reperfusion in the conscious dog, Am J Cardiol, 42, 234, 10.1016/0002-9149(78)90905-0

West, 1978, Compromised microvascular integrity in ischemic myocardium, Lab Invest, 38, 677

Ragosta, 1994, Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction: new insights using myocardial contrast echocardiography, Circulation, 89, 2562, 10.1161/01.CIR.89.6.2562

Swinburn, 2001, Intravenous myocardial contrast echocardiography predicts recovery of dysynergic myocardium early after acute myocardial infarction, J Am Coll Cardiol, 38, 19, 10.1016/S0735-1097(01)01317-1

Lepper, 2000, Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction, Circulation, 101, 2368, 10.1161/01.CIR.101.20.2368

Main, 2001, Full-motion pulse inversion power Doppler contrast echocardiography differentiates stunning from necrosis and predicts recovery of left ventricular function after acute myocardial infarction, J Am Coll Cardiol, 38, 1390, 10.1016/S0735-1097(01)01574-1

Balcells, 2002, Detection of myocardial viability by contrast echocardiography in acute myocardial infarction predicts recovery of resting function and contractile reserve, J Am Coll Cardiol

Andrassy, 2002, Myocardial blood volume and the amount of viable myocardium early after mechanical reperfusion of acute myocardial infarction: prospective study using venous contrast echocardiography, Heart, 87, 350, 10.1136/heart.87.4.350

Lieberman, 1981, Two-dimensional echocardiography and infarct size: relationship of regional wall motion and thinning to the extent of myocardial infarction in the dog, Circulation, 63, 739, 10.1161/01.CIR.63.4.739

Myers, 1986, Direct measurement of inner and outer wall thickening dynamics with epicardial echocardiography, Circulation, 74, 164, 10.1161/01.CIR.74.1.164

Senior, 1995, Technetium 99m-labeled sestamibi imaging reliably identifies retained contractile reserve in dyssynergic myocardial segments, J Nucl Cardiol, 2, 296, 10.1016/S1071-3581(05)80073-X

Sakuma, 1996, Usefulness of myocardial contrast echocardiography for the assessment of serial changes in risk area in patients with acute myocardial infarction, Am J Cardiol, 78, 1273, 10.1016/S0002-9149(96)00610-8

Kaul, 1995, There may be more to myocardial viability than meets the eye!, Circulation, 92, 2790, 10.1161/01.CIR.92.10.2790

deFilippi, 1995, Comparision of myocardial contrast echocardiography and low dose dobutamine stress echocardiography in predicting recovery of left ventricular function after coronary revascularization in chronic ischemic heart disease, Circulation, 92, 2863, 10.1161/01.CIR.92.10.2863

Gould, 1974, Effects on coronary stenoses on coronary flow reserve and resistance, Am J Cardiol, 34, 48, 10.1016/0002-9149(74)90092-7

Kaul, 1997, Detection of coronary artery disease with myocardial contrast echocardiography: comparison with99mTc-sestamibi single-photon emission computed tomography, Circulation, 96, 785, 10.1161/01.CIR.96.3.785

Jarhult, 1973, Autoregulation of capillary hydrostatic pressure in skeletal muscle during regional arterial hypo- and hypertension, Acta Physiol Scand, 91, 32, 10.1111/j.1748-1716.1974.tb05654.x

Johnson Paul, 1986, Autoregulation of blood flow, Circ Res, 59, 483, 10.1161/01.RES.59.5.483

Chilian, 1986, Microvascular distribution of coronary vascular resistance in beating left ventricle, Am J Physiol, 251, H779

Jayaweera, 1999, Role of capillaries in determining coronary blood flow reserve, Am J Physiol, 277, H2363

Wei, 2001, Detection and quantification of coronary stenosis with myocardial contrast echocardiography, Prog Cardiovasc Dis, 44, 81, 10.1053/pcad.2001.26444

Wei, 1998, Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?, J Am Coll Cardiol, 32, 252, 10.1016/S0735-1097(98)00212-5

Ronderos, 2002, Correlation between myocardial perfusion abnormalities detected with intermittent imaging using intravenous perfluorocarbon microbubbles and radioisotope imaging during high-dose dipyridamole stress echo, Clin Cardiol, 25, 103, 10.1002/clc.4960250305

DeMaria, 2001, PB127 phase 2 trial results: concordance of perfusion echocardiography with stress SPECT, Circulation, 104, II

Wei, 2001, Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography, Circulation, 103, 2560, 10.1161/01.CIR.103.21.2560

Bin, 2002, Dobutamine versus dipyridamole for inducing reversible perfusion defects in chronic multivessel coronary artery stenosis, J Am Coll Cardiol, 40, 167, 10.1016/S0735-1097(02)01908-3

Leong-Poi, 2001, Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography, J Am Soc Echocardiogr, 14, 1173, 10.1067/mje.2001.115982

Shimoni, 2001, Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography, J Am Coll Cardiol, 37, 741, 10.1016/S0735-1097(00)01179-7

Porter, 2001, Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging, J Am Coll Cardiol, 37, 748, 10.1016/S0735-1097(00)01204-3

Leong-Poi, 2002, Perfusion versus function: the ischemic cascade in demand ischemia, Circulation, 105, 987, 10.1161/hc0802.104326

Gallagher, 1990, Transmural steal with isoproterenol and exercise in poststenotic myocardium, Basic Res Cardiol, 85, 145

Folts, 1977, Hemodynamic effects of controlled degrees of coronary artery stenosis in short-term and long-term studies in dogs, J Thorac Cardiovasc Surg, 73, 722, 10.1016/S0022-5223(19)41472-4

Krams, 1990, Coronary oscillatory flow amplitude is more affected by perfusion pressure than ventricular pressure, Am J Physiol, 258, H1889

Chilian, 1981, Capacitance function of epicardial coronary arteries, Fed Proc, 40, 603

Wei, 2002, Non-invasive detection of coronary artery stenosis at rest without recourse to exercise or pharmacologic stress, Circulation, 105, 218, 10.1161/hc0202.101986

Lindner, 2000, Microbubble persistence in the microcirculation during ischemia-reperfusion and inflammation: integrin- and complement-mediated adherence to activated leukocytes, Circulation, 101, 668, 10.1161/01.CIR.101.6.668

Lindner, 2000, Non-invasive imaging of inflammation by ultrasound detection of phagocytosed microbubbles, Circulation, 102, 531, 10.1161/01.CIR.102.5.531

Lindner, 2000, Noninvasive ultrasound imaging of inflammation using microbubbles targeted to activated leukocytes, Circulation, 102, 2745, 10.1161/01.CIR.102.22.2745

Christiansen, 2002, Non-invasive imaging of myocardial reperfusion injury using leukocyte-targeted contrast echocardiography, Circulation, 105, 1764, 10.1161/01.CIR.0000015466.89771.E2

Villanueva, 1998, Microbubbles targeted to intercellular adhesion molecule-I bind to activated coronary endothelial cells, Circulation, 98, 1, 10.1161/01.CIR.98.1.1

Demos, 1999, In vivo targeting of acoustically reflective liposomes for intravascular and transvalvular ultrasonic enhancement, J Am Coll Cardiol, 33, 867, 10.1016/S0735-1097(98)00607-X

Lindner, 2001, Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin, Circulation, 104, 2107, 10.1161/hc4201.097061

Unger, 1998, In vitro studies of a new thrombus-specific ultrasound contrast agent, Am J Cardiol, 81, 58, 10.1016/S0002-9149(98)00055-1

Lanza, 1997, A novel site-targeted ultrasonic contrast agent with broad biomedical application, Circulation, 95, 3334

JR Lindner, Evolving applications for contrast ultrasound, Am J Cardiol (In press).

Francis, 1992, Enhancement of fibrinolysis in vitro by ultrasound, J Clin Invest, 90, 2063, 10.1172/JCI116088

Tachibana, 1995, Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis, Circulation, 92, 1148, 10.1161/01.CIR.92.5.1148

Porter, 2001, Effectiveness of transcranial and transthoracic ultrasound and microbubbles in dissolving intravascular thrombi, J Ultrasound Med, 20, 1313, 10.7863/jum.2001.20.12.1313

H Leong-Poi, J Christiansen, AL Klibanov, S Kaul, JR Lindner, Non-invasive assessment of angiogenesis by ultrasound and microbubbles targeted to αv-integrins, J Am Coll Cardiol (In press).

Shohet, 2000, Echocardiographic destruction of albumin microbubbles directs gene delivery to the myocardium, Circulation, 101, 2554, 10.1161/01.CIR.101.22.2554

Frenkel, 2002, DNA-loaded albumin microbubbles enhance ultrasound-mediated transfection in vitro, Ultrasound Med Biol, 28, 817, 10.1016/S0301-5629(02)00518-5

Vannan, 2002, Ultrasound-mediated transfection of canine myocardium by intravenous administration of cationic microbubble-linked plasmid DNA, J Am Soc Echocardiogr, 15, 214, 10.1067/mje.2002.119913

JP Christiansen, BA French, AL Klibanov, S Kaul, JR Lindner, Targeted tissue transfection with ultrasound destruction of plasmid-bearing cationic microbubbles, J Am Coll Cardiol (In press).

Tamiyama, 2002, Local delivery of plasmid DNA into a rat carotid artery using ultrasound, Circulation, 105, 1233, 10.1161/hc1002.105228

Porter, 2001, Inhibition of carotid artery neointimal formation microbubbles, Ultrasound Med Biol, 27, 259, 10.1016/S0301-5629(00)00338-0

Bao, 1997, Transfection of a reporter plasmid into cultured cells by sonoporation in vitro, Ultrasound Med Biol, 23, 953, 10.1016/S0301-5629(97)00025-2

Greenleaf, 1990, Artificial cavitation nuclei significantly enhance acoustically induced cell transfection, Ultrasound Med Biol, 24, 587, 10.1016/S0301-5629(98)00003-9

Miller, 1999, Sonoporation of cultured cells in the rotating tube exposure system, Ultrasound Med Biol, 25, 143, 10.1016/S0301-5629(98)00137-9

Skyba, 1998, Direct in vivo visualization of intravascular destruction of microbubbles by ultrasound and its local effects on tissue, Circulation, 98, 290, 10.1161/01.CIR.98.4.290

Unger, 1998, Acoustically active lipospheres containing Paclitaxil: a new therapeutic ultrasound contrast agent, Invest Radiol, 12, 886, 10.1097/00004424-199812000-00007