Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows

Journal of Exposure Science and Environmental Epidemiology - Tập 12 Số 4 - Trang 296-306 - 2002
Lance Wallace1, Steven J. Emmerich2, Cynthia Howard-Reed2
1US EPA, 12201 Sunrise Valley Drive, 555 National Center, Reston, USA
2National Institute of Standards and Technology, Gaithersburg, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

ASTM Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution, E741-95, American Society for Testing and Materials, Philadelphia, PA (1995)

ASTM Standard Test Method for Determining Air Leakage Rate by Fan Pressurization, E779-99, American Society for Testing and Materials, Philadelphia, PA (1999)

Bahnfleth DR Moseley TT Harris WS Measurement of infiltration in two residences: Part I. Technique and measured infiltration, ASHRAE Trans (1957) 63: 453–476

Burch DM Hunt CM Retrofitting an Exiting Wood Frame Residence for Energy Conservation — Air Experimental Study, Building Science Series 105, National Bureau of Standards, Washington, DC (1978)

Coblentz CW Achenbach PR Field measurements of air infiltration in ten electrically-heated houses, ASHRAE Trans (1963) 69: 358–365

Dick JB The fundamentals of natural ventilation of houses, J Inst Heat Vent Eng (1950) 18: 123–134

Dick JB Thomas DA Ventilation research in occupied houses, J Inst Heat Vent Eng (1951) 19: 306–326

Emmerich SJ Nabinger SJ Measurement and Simulation of the Impact of Particle Air Cleaners in a Single-Zone Building, National Inst Standards Tech NISTIR 6461, Gaithersburg, MD (2000

Etheridge D Sandberg M Building Ventilation: Theory and Measurement. Wiley, New York 1996

Goldschmidt VW Leonard GR Ball JE Wilhelm DR Wintertime infiltration rates in mobile homes In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 107–124

Haldane JS Report of the Departmental Committee appointed to enquire into the Manufacture and Use of Water Gas and Other Gases Containing a Large Proportion of Carbonic Oxide. Appendix I. HMSO, C. 9164, 1899 1899

Howard-Reed CH Wallace LA Ott WR The effect of opening windows on air change rates in two homes, J Air Waste Manage Assoc (2002) 52: 174–185

Hunt CM Air infiltration: a review of some existing measurement techniques and data In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 3–23

Hunt CM King JC Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980

Lagus PL Air leakage measurements by the tracer dilution method In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 16–49

Lagus PL King JC Air leakage and fan pressurization measurements in selected naval housing In: Trechsel H.R., and Lagus P.L. (Eds.) Measured Air Leakage of Buildings, STP 904. American Society for Testing and Materials, Philadelphia, PA 1986 pp 5–16

Laschober RR Healy JH Statistical analyses of air leakage in split-level residences, ASHRAE Trans (1964) 70: 364–374

Malik N Field studies of dependence of air infiltration on outside temperature and wind, Energy Build (1978) 1: 281–292

Murray DM Burmaster DE Residential air exchange rates in the United States: empirical and estimated parametric distributions by season and climatic region, Risk Anal (1995) 15(4): 459–465

Nazaroff WW Feustel H Nero AV Rexvan KL Grimsrud DT Essling MA Toomey RE Radon transport into a detached one-story house with a basement, Atmos Environ (1985) 19(1): 31–46

Palmiter LS Brown IA Bond TC Measured infiltration and ventilation in 472 all-electric homes, ASHRAE Trans (1991): 979–987

Persily AK Measurements of air infiltration and airtightness in passive solar homes In: Trechsel H.R., and Lagus P.L. (Eds.)Measured Air Leakage of Buildings, STP 904. American Society for Testing and Materials, Philadelphia, PA 1986 pp 46–60

Pettenkofer MV Ueber den Luftwechsel in Wohngebäuden, Munich 1858

Sinden FW Wind, temperature and natural ventilation — theoretical considerations, Energy Build (1978) 1: 275–280

Trechsel HR Lagus PL (Eds.) Measured Air Leakage of Buildings, STP 904. American Society for Testing and Materials, Philadelphia, PA 1986

Wang FS Sr Sepsy CF Field studies of the air tightness of residential buildings In: Hunt C.M., King J.C., and Trechsel H.R. (Eds.) Building Air Change Rate and Infiltration Measurements, STP 719. American Society for Testing and Materials, Philadelphia, PA 1980 pp 24–35

Warner CG Measurements of the ventilation of dwellings, J Hyg (1940) 40: 125–153