Continuous glucose monitoring and closed‐loop systems

Diabetic Medicine - Tập 23 Số 1 - Trang 1-12 - 2006
Roman Hovorka1
1Diabetes Modelling Group, Department of Paediatrics, University of Cambridge, Cambridge, UK

Tóm tắt

AbstractBackground  The last two decades have witnessed unprecedented technological progress in the development of continuous glucose sensors, resulting in the first generation of commercial glucose monitors. This has fuelled the development of prototypes of a closed‐loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump.Method  A review of electromechanical closed‐loop approaches is presented. This is followed by a review of existing prototypes and associated glucose sensors. A literature review was undertaken from 1960 to 2004.Results  Two main approaches exist. The extracorporeal s.c.–s.c. approach employs subcutaneous glucose monitoring and subcutaneous insulin delivery. The implantable i.v.–i.p. approach adopts intravenous sampling and intraperitoneal insulin delivery. Feasibility of both solutions has been demonstrated in small‐scale laboratory studies using either the classical proportional–integral–derivative controller or a model predictive controller. Performance in the home setting has yet to be demonstrated.Conclusions  The glucose monitor remains the main limiting factor in the development of a commercially viable closed‐loop system, as presently available monitors fail to demonstrate satisfactory characteristics in terms of reliability and/or accuracy. Regulatory issues are the second limiting factor. Closed‐loop systems are likely to be used first by health‐care professionals in controlled environments such as intensive care units.

Từ khóa


Tài liệu tham khảo

10.1111/j.1749-6632.1960.tb23229.x

Kadish AH., 1964, Automation control of blood sugar. I. A servomechanism for glucose monitoring and control, Am J Med Electron, 39, 82

10.2337/diab.23.5.389

10.2337/diab.23.5.397

10.1055/s-0028-1093841

Clemens AH, 1977, The development of Biostator, a glucose‐controlled insulin infusion system (GCIIS), Horm Metab Res Supplement, 7, 23

10.1109/TBME.1976.324639

10.2337/diabetes.26.7.663

10.1111/j.1445-5994.1977.tb03687.x

10.1109/TBME.1981.324661

10.1136/bmj.1.6107.204

Panteleon AE, 2004, A novel approach for closed loop control of meal‐induced carbohydrate uptake, Diabetes Technol Ther, 6, 265

10.2337/diacare.25.3.593

Shimoda S, 1997, Closed‐loop subcutaneous insulin infusion algorithm with a short‐acting insulin analog for long‐term clinical application of a wearable artificial endocrine pancreas, Front Med Biol Eng, 8, 197

10.2337/diacare.25.11.2053

10.1152/ajpendo.00304.2001

10.1152/ajpendo.1999.277.3.E561

10.1089/152091503322250578

10.2337/diacare.9.2.124

10.1055/s-2001-18592

10.1016/S1262-3636(07)70075-7

10.1016/S1262-3636(07)70045-9

10.1089/152091503322527049

10.1089/152091504774198034

10.1109/51.897829

10.1016/j.addr.2003.08.011

Clemens AH., 1979, Feedback control dynamics for glucose‐controlled insulin infusion system, Med Prog Technol, 6, 91

10.1109/10.740877

LynchSM BequetteBW.Estimation‐based model predictive control of blood glucose in type I diabetics: A simulation study.Proceedings of the of the IEEE 27th Annual Northeast Bioengineering Conference2001 79–80.

10.1109/10.709556

10.1088/0967-3334/25/4/010

10.1007/978-1-4471-3398-8

10.1016/0025-5564(82)90050-5

10.1109/TBME.1985.325500

10.2337/diacare.12.10.725

10.1147/sj.314.0635

10.2337/diab.19.9.644

10.1111/j.0954-6820.1965.tb01810.x

10.1055/s-2007-979906

10.1089/dia.2005.7.72

Shichiri M., 2000, Artificial Endocrine Pancreas: Development and Clinical Applications

Goriya Y, 1979, The development of an artificial beta cell system and its validation in depancreatized dogs: the physiological restoration of blood glucose homeostasis, Med Prog Technol, 6, 99

10.1016/S0140-6736(82)92788-X

Kawamori R, 1986, Progress in Artificial Organs, 647

Shimoda S, 2001, Development of closed‐loop intraperitoneal insulin infusion algorithm for a implantable artificial endocrine pancreas, Diabetes, 50, A3

10.2337/diacare.17.5.387

10.1046/j.1525-1594.1998.06043.x

10.2337/diacare.10.5.622

10.2337/diacare.20.6.911

10.1089/152091504774197990

10.1152/ajpendo.1999.276.2.E401

Schaller HC, 2002, MPC algorithm controls blood glucose in patients with type 1 diabetes mellitus under fasting conditions using the IV‐SC route, Diabetes Technol Ther, 4, 234

Schaller HC, 2002, Feasibility of the SC‐SC route for an extracorporeal artificial pancreas, Diabetes, 51, 462

Schaller HC, 2005, On‐line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with type 1 diabetes, Diabet Med

Schaller HC, 2003, DM under daily life conditions, Diabetes Metab, 29, A2225

10.1007/s001250051637

Vering T., 2004, Minimally invasive control loop system for SC‐SC control on patients with type 1 diabetes, Diabetes Technol Ther, 6, 278

Mastrototaro J., 1999, The MiniMed continuous glucose monitoring system (CGMS), J Pediatr Endocr Met, 12, 751

10.1016/0956-5663(92)85053-D

10.1046/j.1464-5491.2003.01037.x

10.1089/152091500316737

10.1016/S1262-3636(07)70023-X

10.2337/diacare.27.3.722

10.2337/diacare.25.9.1499

10.1016/j.jpeds.2004.03.042

10.2337/diacare.25.7.1185

10.2337/diacare.26.3.582

10.2337/diacare.26.1.256

10.1002/dmrr.309

10.1111/j.1440-1754.2004.00307.x

10.1016/S1262-3636(07)70076-9

10.1542/peds.111.5.933

10.1089/152091504773731285

10.1172/JCI107011

10.2337/diabetes.51.2007.S103

10.1152/ajpendo.00139.2003

10.1089/152091503322640999

10.1210/jcem-63-2-492

Fieseler P, 1995, Physiological augmentation of amino acid‐induced insulin‐ secretion by GIP and GLP‐I but not by CCK‐8, Am J Physiol, 31, E949

Louis Sylvestre J., 1987, The cephalis phase of insulin secretion, Diabetes Metab, 13, 63

Steil GM, 2002, Tuning closed‐loop insulin delivery based on known daily insulin requirements, Diabetes, 51, 510

Steil GM, 2004, Continuous automated insulin delivery based on subcutaneous glucose sensing and an external insulin pump, Diabetes, 53, A2

Renard E, 2002, From external to implantable insulin pump, can we close the loop?, Diabetes Metab, 28, S19

10.1016/S1471-4892(02)00216-3

Renard E, 2003, Sustained safety and accuracy of central IV glucose sensors connected to implanted insulin pumps and short‐term closed‐loop trials in diabetic patients, Diabetes, 52, A36

Shah R, 2001, Automatic feedback control of plasma glucose levels in diabetic canines, Diabetes, 50, A3

StarkweatherTJ LebelRJ ShahR MillerME.System and method for providing closed loop infusion formulation delivery. US Patent 6740042 2004:1–29.

Renard E, 2004, Efficacy of closed loop control of blood glucose based on an implantable i.v. sensor and intraperitoneal pump, Diabetes, 53, A114

10.1089/152091503322250613

Galley P, 2004, Use of subcutaneous glucose measurements to drive real‐time algorithm‐directed insulin infusion recommendations, Diabetes Technol Ther, 6, 245

GalleyPJ ThukralA ChittajalluSK WeinertS.Diabetes management system. US Patent 6544212 2003:1–17.

Thukral A, 2004, Conversion of an empirical closed loop algorithm into the MPC framework, Diabetes Technol Ther, 6, 275

10.1055/s-2001-18594

10.1089/152091501300209615

Kalatz B, 1999, Development of algorithms for feedback‐controlled subcutaneous insulin infusion with insulin lispro, Acta Diabetol, 36, 215

KalatzB.Algorithmen zur Glucosegesteuerten Insulininfusion bei Diabetes Mellitus—Entwicklung und Experimentelle Untersuchung.Medical Dissertation.Ulm Germany: University of Ulm 1999.

10.1056/NEJMoa011300

10.1161/01.CIR.99.20.2626

10.1109/TITB.2003.808509

10.1345/aph.1E018

10.2337/diacare.27.2.461

Goldberg PA, 2004, Implementation of a safe, effective insulin infusion protocol (IIP) in the cardiothoracic (CT) intensive care unit (ICU), Diabetes, 53, A109

10.1016/j.ecl.2003.12.001

10.1002/dmrr.188

Canonico V, 2002, Evaluation of a feedback model based on simulated interstitial glucose for continuous insulin infusion, Diabetologia, 45, 995

10.1089/152091504773731285