Concept, design and fabrication of smart orthopedic implants

Medical Engineering & Physics - Tập 22 Số 7 - Trang 469-479 - 2000
F Burny1, M Donkerwolcke1, F Moulart1, R Bourgois2, Robert Puers3, Koenraad Van Schuylenbergh3, Mário A. Barbosa4,5, Olga C. Paiva4,6, Francis Rodes7, Jean-Baptiste Bégueret7, P Lawes8
1Service d'Orthopédie-Traumatologie, Cliniques Universitaires de Bruxelles, Hôpital Erasme, Brussels, Belgium
2Royal Military Academy, Brussels, Belgium
3Elektrotechniek, E.S.A.T.-M.I.C.A.S. KULeuven, Leuven, Belgium
4Department Metallurgy, INEB-Institute de Engenharia Biomédica, Porto, Portugal
5Faculdade de Engenharia da Universidade do Porto, Porto, Portugal
6Instituto Politécnico do Porto, OPorto, Portugal
7IXL, Université de Bordeaux I, Bordeaux, France
8Howmedica International Inc., Raheen, Ireland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Burny, 1993, Clinical application of the monitoring of orthopedic implants, 138

Burny, 1971, Utilisation des jauges extensométriques pour la mesure de la consolidation des fractures du tibia traitées par enclouage centromédullaire. Etude théorique et premiers résultats, Acta Orthop. Belg., 37, 266

Moulart F. Rééducation des fractures hautes du fémur. Mesure des déformations du matériel d'ostéosynthese. Mémoire de Licence en Kinésithérapie, Université Libre de Bruxelles, 1975.

Burny, 1976, Traitement des fractures métastatiques de la region sous-trochantérienne. Etude biomécanique; cas cliniques, Acta Orthop. Belg., 42, 31

Burny, 1991, Telemetry in the musculoskeletal system, 391

Puers R, Burny F. Biotelemetry in orthopaedics. In: Muster D. et al., editors. European Materials Research Society Monographs. Biomaterials. Hard Tissue Repair and Replacement, vol. 3. Amsterdam: Elsevier, 1992:285–306.

Kadefors, 1969, Energizing implantable transmitters by means of coupled inductance coils, IEEE Trans. Biomed. Eng., BME-16, 177, 10.1109/TBME.1969.4502641

Ko, 1977, Design of radio-frequency powered coils for implant intruments, Med. Biol. Eng. Comput., 15, 634, 10.1007/BF02457921

Donaldson, 1983, Analysis of resonant coupled coils in the design of radio frequency trancutaneous links, Med. Biol. Eng. Comput., 21, 612, 10.1007/BF02442388

Grossman, 1978, Machining a machinable glass-ceramic, Vacuum, 28, 55, 10.1016/S0042-207X(78)80514-4

Van Schuylenbergh, 1993, The influence of moisture leakage on implant strain measurements with resistive strain gauges, 125

Wranglén, 1985

Barbosa, 1992, Surface layers and the reactivity of metallic implants, 257

Nicholas, 1986, Active metal brazing, British Ceramic Transactions Journal, 85, 144

Pattee, 1972, Joining ceramics to metals and other materials, Welding Research Council Bulletin, New York, 178, 2435

Nicholas, 1989, Brazing ceramics with alloys containing titanium, Ceramic Engineering and Science Proceedings, 10, 1602, 10.1002/9780470312568.ch9

Rodes, 1993, Direct digitization of low level transducer outputs for low power intracorporal telemetry systems, 401

Flack, 1971, Mutual inductance of air-cored coils: effect on design of radio-frequency coupled implants, Med. Biol. Eng. Comput., 9, 79, 10.1007/BF02474736

Donkerwolcke, 1993, The zero drift, a monitoring problem, 89