Comparison of lithium dilution and thermodilution cardiac output measurements in anaesthetised neonatal foals

Equine Veterinary Journal - Tập 34 Số 6 - Trang 598-601 - 2002
Kevin T.T. Corley1,2, Lydia Donaldson1,2, Martin Furr1,2
1Marion duPont Scott Equine Medical Center, VMRCVM, PO Box 1938, Leesburg, Virginia, USA
2Royal Veterinary College, Hawkeshead Lane, North Mymms, Hertfordshire AL9 7TA, UK

Tóm tắt

Summary

Knowledge of cardiac output is expected to help guide the treatment of hypotension associated with critical illness and/or anaesthesia in neonatal foals. However, a practical and safe method of measuring cardiac output has not been described for the foal. Lithum dilution, a new method of cardiac output determination not requiring cardiac catheterisation, has recently been reported in mature horses. We compared this method to thermodilution in isoflurane‐anaesthetised foals age 30–42 h and found good agreement between the 2 methods in a range of cardiac outputs 5.4–20.41/min. The lithium dilution technique is a practical and reliable method of measuring cardiac output in anaesthetised neonatal foals, and warrants investigation in critically ill conscious foals.

Từ khóa


Tài liệu tham khảo

10.1113/jphysiol.1985.sp015757

10.1016/S0140-6736(86)90837-8

Cohen N.D., 1994, Causes of and farm management factors associated with disease and death in foals, J. Am. vet. med. Ass., 204, 1644, 10.2460/javma.1994.204.10.1644

10.1001/jama.1996.03540110043030

Drummond W.H., 1990, Equine Clinical Neonatology, 106

10.1097/00003246-198911000-00002

10.1378/chest.76.6.647

Furr M., 1997, Perinatal asphyxia in foals, Comp. cont. Educ. pract. Vet., 18, 1342

10.2460/ajvr.2001.62.1387

10.1007/BF01711553

10.1111/j.2042-3306.1990.tb04198.x

10.1007/s001340050578

10.1097/00003246-199711000-00015

10.1007/s001340051347

10.2460/ajvr.2000.61.731

10.1097/00000539-200003000-00018

Mason D.J. O'Grady M. Woods J.P.andMcDonell W.(2000)Lithium chloride dilution as a new method of cardiac output determination in the dog: effect of lithium chloride dosage on serum lithium concentration. In:Proceedings of the Annual Meeting of the American College of Veterinary Anaesthesia. p16.

McGuirk S.M., 1984, Thermo dilution curves for diagnosis of ventricular septal defect in cattle, J. Am. vet. med. Ass., 184, 1141

10.1097/00003246-199404000-00011

10.1007/BF03027130

10.1111/j.2042-3292.1997.tb01274.x

10.1016/S0007-1935(17)39652-5

Schlipf J.W. Dunlop C.I. Getzy D.M. Wagner A.E.andWertz E.M.(1994)Lesions associated with cardiac catheterization and thermodilution cardiac output determination in horses. In:Proceedings of the 5th International Congress of Veterinary Anaesthesia. p71.

Scott E.A., 1975, Closure of ductus arteriosus determined by cardiac catheterization and angiography in newborn foals, Am. J. vet. Res., 36, 1021

10.3109/00016925309136722

10.1378/chest.99.6.1451

Thomas W.P., 1987, Systemic and pulmonary haemodynamics in normal neonatal foals, J. reprod. Fert., 35, 623

Vaala W.E., 1990, Equine Clinical Neonatology, 262