Comparison of initial detection and redetection of ventricular fibrillation in a transvenous defibrillator system with automatic gain control

Journal of the American College of Cardiology - Tập 25 - Trang 431-436 - 1995
Charles I. Berul1, David J. Callans1, David S. Schwartzman1, Mark W. Preminger1, Charles D. Gottlieb1, Francis E. Marchlinski1
1Clinical Electrophysiology Laboratory of the Philadelphia Heart Institute, Presbyterian Medical Center, Philadelphia, Pennsylvania, USA

Tài liệu tham khảo

Saksena, 1988, Implantation of a cardioverter/defibrillator without thoracotomy using a triple electrode system, JAMA, 259, 69, 10.1001/jama.1988.03720010047039 McCowan, 1991, Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardiol and submuscular patch system, J Am Coll Cardiol, 17, 415, 10.1016/S0735-1097(10)80108-1 Yee, 1992, A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator: nonthoracotomy approach to implantation, Circulation, 85, 1689, 10.1161/01.CIR.85.1.196 Jordaens, 1993, Experience of cardioverter-defibrillators inserted without thoracotomy: evaluation of transvenously inserted intracardiac leads alone or with a subcutaneous axillary patch, Br Heart J, 69, 14, 10.1136/hrt.69.1.14 Trappe, 1993, Initial experience with a new transvenous defibrillation system, PACE Pacing Clin Electrophysiol, 16, 134, 10.1111/j.1540-8159.1993.tb01550.x Hauser, 1993, Clinical results with nonthoracotomy lead ICD systems, PACE Pacing Clin Electrophysiol, 16, 141, 10.1111/j.1540-8159.1993.tb01551.x Bardy, 1993, Implantable transvenous cardioverter-defibrillators, Circulation, 87, 1152, 10.1161/01.CIR.87.4.1152 Brooks, 1993, Determinants of successful nonthoracotomy cardioverter-defibrillator implantation: experience in 101 patients using two different lead systems, J Am Coll Cardiol, 22, 1835, 10.1016/0735-1097(93)90766-T Bhandari, 1992, Intraoperative defibrillation efficacy of endocardial subcutaneous lead configurations, Circulation, 86, I Yee, 1984, Changes in pacing threshold and R wave amplitude after transvenous catheter countershock, J Am Coll Cardiol, 4, 543, 10.1016/S0735-1097(84)80099-6 Yee, 1984, Pacing threshold changes after transvenous catheter countershock, Am J Cardiol, 53, 503, 10.1016/0002-9149(84)90021-3 Isbruch, 1991, Influence of defibrillation shocks on the endocardial sensing signal of an integrated sense/pace/defibrillation lead, Eur Heart J, 12, 363 Isbruch, 1992, Reduction of the endocardial sensing signal of an integrated sense/pace/defibrillation lead after application of defibrillation shocks, PACE Pacing Clin Electrophysiol, 15, II Jung, 1992, Failure of an implantable cardioverter defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system, Circulation, 86, 1217, 10.1161/01.CIR.86.4.1217 Herre, 1993, Detection and redetection characteristics of the Endotak C transvenous lead system, Circulation, 88, I Crowley, 1973, Electrical breakdown of biomolecular membranes as an electromechanical instability, Biophys J, 13, 711, 10.1016/S0006-3495(73)86017-5 Jones, 1978, Response of cultured myocardial cells to countershock-type electrical field stimulation, Am J Physiol, 235, H214 Li, 1993, Defibrillation shocks produce different effects on Purkinje fibers and ventricular muscle: implications for successful defibrillation, refibrillation and postshock arrhythmia, J Am Coll Cardiol, 22, 607, 10.1016/0735-1097(93)90072-9 Bardy, 1988, Does unsuccessful defibrillation adversely affect subsequent AICD sensing of ventricular fibrillation, PACE Pacing Clin Electrophysiol, 11, 485 Jung, 1993, Change in amplitude of endocardial electrograms following defibrillator discharge: comparison of two lead systems, J Am Coll Cardiol, 21, 126A Isbruch, 1993, Significant improvement of the endocardial post shock sensing signal using a new design in an integrated sense/pace/defibrillation lead, Circulation, 88, 1 Bardy, 1986, Failure of the automatic implantable defibrillator to detect ventricular fibrillation, Am J Cardiol, 58, 1107, 10.1016/0002-9149(86)90124-4 Bardy, 1989, A prospective, randomized evaluation of effect of ventricular fibrillation duration on defibrillation thresholds in humans, J Am Coll Cardiol, 13, 1362, 10.1016/0735-1097(89)90311-2 Marchlinski, 1988, Relation of the interoperative defibrillation threshold to successful postoperative defibrillation with an automatic implantable cardioverter defibrillator, Am J Cardiol, 62, 393, 10.1016/0002-9149(88)90965-4