Comparison of gastric emptying of a nondigestible capsule to a radio‐labelled meal in healthy and gastroparetic subjects

Alimentary Pharmacology and Therapeutics - Tập 27 Số 2 - Trang 186-196 - 2008
Braden Kuo1, Richard W. McCallum, Kenneth L. Koch, Michael D. Sitrin, John M. Wo, William D. Chey, William L. Hasler, Jeffrey M. Lackner, Leonard Katz, John R. Semler, Gregory E. Wilding, Henry P. Parkman
1Gastroenterology Unit, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. [email protected]

Tóm tắt

SummaryBackground  Gastric emptying scintigraphy (GES) using a radio‐labelled meal is used to measure gastric emptying. A nondigestible capsule, SmartPill, records luminal pH, temperature, and pressure during gastrointestinal transit providing a measure of gastric emptying time (GET).Aims  To compare gastric emptying time and GES by assessing their correlation, and to compare GET and GES for discriminating healthy subjects from gastroparetics.Methods  Eighty‐seven healthy subjects and 61 gastroparetics enrolled with simultaneous SmartPill and GES. Fasted subjects were ingested capsule and [99mTc]‐SC radio‐labelled meal. Images were obtained every 30 min for 6 h. Gastric emptying time and percentage of meal remaining at 2/4 h were determined for each subject. The sensitivity/specificity and receiver operating characteristic analysis of each measure were determined for each subject.Results  Correlation between GET and GES‐4 h was 0.73 and GES‐2 h was 0.63. The diagnostic accuracy from the receiver operating characteristic curve between gastroparetics and healthy subjects was GET = 0.83, GES‐4 h = 0.82 and GES‐2 h = 0.79. The 300‐min cut‐off time for GET gives sensitivity of 0.65 and specificity of 0.87 for diagnosis of gastroparesis. The corresponding sensitivity/specificity for 2 and 4 h standard GES measures were 0.34/0.93 and 0.44/0.93, respectively.Conclusion  SmartPill GET correlates with GES and discriminates between healthy and gastroparetic subjects offering a nonradioactive, standardized, ambulatory alternative to scintigraphy.

Từ khóa


Tài liệu tham khảo

10.1053/j.gastro.2004.09.055

10.1023/A:1018970323716

10.1046/j.1365-2036.2002.01344.x

10.1016/S0016-5085(97)70126-4

Kuo B, 2004, Non‐invasive simultaneous measurement of intra‐luminal pH and pressure: assessment of gastric emptying and upper GI manometry in healthy subjects, Neurogastroenterology, 16, 666

10.1016/S0025-6196(12)62245-9

10.1023/A:1015998708560

Gordon SJ, 1987, Measurement of gastric residence time (GRT) by Heidelberg capsule (HC) reproducibility in normal subjects and application in diabetic gastroparesis, Gastroenterology, 92, 1410

10.1016/0016-5085(85)90342-7

10.1136/gut.29.8.1035

10.1111/j.1572-0241.2000.02076.x

Faegenburg D, 1985, Intestinal obstruction caused by ingestion of a Heidelberg capsule: report of a case, Am J Gastroenterol, 80, 787

10.1016/S0016-5085(03)81232-5

10.1111/j.1572-0241.2005.40722.x

10.1007/b97377

10.1016/0016-5085(84)90085-4

Cassilly DW, 2007, Simultaneous use of SmartPill pH and pressure capsule, antroduodenal manometry and gastric emptying scintigraphy to assess gastric emptying of digestible and non‐digestible solids, Gastroenterology, 132, A‐97

Rao SS, 2007, A comparative study of SmartPill and radioopaque markers for the assessment of colonic transit time in humans, Gastroenterology, 132, A‐458