Comparison of dynamic measurements of pulse contour with pulsed heat continuous cardiac output in postoperative cardiac surgical patients

Australian Critical Care - Tập 20 Số 1 - Trang 27-32 - 2007
Martin Boyle1, John C. Lawrence1, Andrew Belessis1, Margherita Murgo1, Yahya Shehabi1
1Intensive Care, Prince of Wales Hospital, Barker St., Randwick, NSW 2031, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Yelderman, 1992, Continuous thermodilution cardiac output measurement in intensive care unit patients, J Cardiothorac Vasc Anesth, 6, 270, 10.1016/1053-0770(92)90137-V

Boldt, 1994, Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?, Crit Care Med, 22, 1913, 10.1097/00003246-199422120-00005

PiCCO plus Operator's manual and Product Information: Pulsion Medical Systems, Munich.

Felbinger, 2005, Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysis, J Clin Anesth, 17, 241, 10.1016/j.jclinane.2004.06.013

Della Rocca, 2003, Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation, Can J Anaesth, 50, 707, 10.1007/BF03018714

Sakka, 1999, Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients, Intensive Care Med, 25, 843, 10.1007/s001340050962

Bock, 1988, Thermal recovery after passage of the pulmonary circulation assessed by deconvolution, J Appl Physiol, 64, 1210, 10.1152/jappl.1988.64.3.1210

Poli de Figueiredo, 1999, Thermal filament continuous thermodilution cardiac output delayed response limits its value during acute hemodynamic instability, J Trauma-Injury Infect Crit Care, 47, 288, 10.1097/00005373-199908000-00011

Aranda, 1998, Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes, Anesthesiology, 89, 1592, 10.1097/00000542-199812000-00047

Rauch, 2002, Pulse contour analysis versus thermodilution in cardiac surgery patients, Acta Anaesthesiol Scand, 46, 424, 10.1034/j.1399-6576.2002.460416.x

Bendjelid, 2006, Continuous cardiac output monitoring after cardiopulmonary bypass: a comparison with bolus thermodilution measurement, Intensive Care Med, 32, 919, 10.1007/s00134-006-0161-2

Mielck, 2003, Comparison of continuous cardiac output measurements in patients after cardiac surgery, J Cardiothorac Vasc Anesth, 17, 211, 10.1053/jcan.2003.49

Buhre, 1999, Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting, J Cardiothorac Vasc Anesth, 13, 437, 10.1016/S1053-0770(99)90216-1

Goedje, 1999, Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution, Critical Care Med, 27, 2407, 10.1097/00003246-199911000-00014

Rodig, 1999, Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients, Br J Anaesth, 82, 525, 10.1093/bja/82.4.525

Godje, 2002, Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability, Crit Care Med, 30, 52, 10.1097/00003246-200201000-00008

Sander, 2005, Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients, Crit Care (London, England), 9, R729, 10.1186/cc3903

Linton, 2001, Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb, Br J Anaesth, 86, 486, 10.1093/bja/86.4.486

Linton, 2002, Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method?, Br J Anaesth, 89, 336, 10.1093/bja/aef530

Vigilance Monitor Operator's Manual: Edwards Critical Care, Irvine; 2000.

Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, 307, 10.1016/S0140-6736(86)90837-8

Critchley, 1999, A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques, J Clin Monit Comput, 15, 85, 10.1023/A:1009982611386

Zollner, 2001, Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination, Can J Anaesth, 48, 1143, 10.1007/BF03020382

McGee, 2005, Validation of a continuous cardiac output measurement using arterial pressure waveforms, Crit Care, 9, S24, 10.1186/cc3125