Comparison of current tonometry techniques in measurement of intraocular pressure
Tài liệu tham khảo
Babalola, 2009, A comparison of the Goldmann applanation and non-contact (Keeler Pulsair EasyEye) tonometers and the effect of central corneal thickness in indigenous African eyes, Ophthalmic Physiol Opt, 29, 182, 10.1111/j.1475-1313.2008.00621.x
Ogbuehi, 2006, Assessment of the accuracy and reliability of the Topcon CT80 non-contact tonometer, Clin Exp Optom, 89, 310, 10.1111/j.1444-0938.2006.00068.x
Kniestedt, 2008, Tonometry through the ages, Surv Ophthalmol, 53, 568, 10.1016/j.survophthal.2008.08.024
ElMallah, 2008, New ways to measure intraocular pressure, Curr Opin Ophthalmol, 19, 122, 10.1097/ICU.0b013e3282f391ae
Tonnu, 2005, The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry, Br J Ophthalmol, 89, 851, 10.1136/bjo.2004.056622
Pache, 2005, Dynamic contour tonometry versus goldmann applanation tonometry: a comparative study, Ger J Ophthalmol, 243, 763
Martinez-de-la-Casa, 2006, Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry, Ophthalmology, 113, 2156, 10.1016/j.ophtha.2006.06.016
Kaufmann, 2004, Comparison of dynamic contour tonometry with goldmann applanation tonometry, Invest Ophthalmol Vis Sci, 45, 3118, 10.1167/iovs.04-0018
Kotecha, 2010, Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers, Ophthalmology, 117, 730, 10.1016/j.ophtha.2009.09.020
Lee, 2009, Comparison between dynamic contour tonometry and goldmann applanation tonometry, Korean J Ophthalmol, 23, 27, 10.3341/kjo.2009.23.1.27
Medeiros, 2006, Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer, J Glaucoma, 15, 364, 10.1097/01.ijg.0000212268.42606.97
Martinez-de-la-Casa, 2006, Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements, Invest Ophthalmol Vis Sci, 47, 4410, 10.1167/iovs.06-0158
Mollan, 2008, Accuracy of goldmann, ocular response analyser, pascal and tonopen XL tonometry in keratoconic and normal eyes, Br J Ophthalmol, 92, 1661, 10.1136/bjo.2007.136473
Ang, 2008, Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma, J Glaucoma, 17, 259, 10.1097/IJG.0b013e31815c3a93
Touboul, 2008, Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry, J Cataract Refract Surg, 34, 616, 10.1016/j.jcrs.2007.11.051
Detry-Morel, 2010, Evaluation of corneal biomechanical properties with the reichert ocular response analyzer, Eur J Ophthalmol, 21, 138, 10.5301/EJO.2010.2150
Bayoumi, 2010, Ocular response analyzer and goldmann applanation tonometry: a comparative study of findings, J Glaucoma, 19, 627, 10.1097/IJG.0b013e3181ca7e01