Comparison of ArcCHECK and portal dosimetry in dose verification for intensity modulated radiotherapy plan for craniospinal irradiation
Tài liệu tham khảo
Chandraraj, 2011, Comparison of four commercial devices for RapidArc and sliding window IMRT QA, Journal of Applied Clinical Medical Physics, 12, 3367, 10.1120/jacmp.v12i2.3367
Covington, 2019, Assessing the feasibility of single target radiosurgery quality assurance with portal dosimetry, Journal of Applied Clinical Medical Physics, 20, 135, 10.1002/acm2.12578
Guo, 2017, A comparative of Matrixx and EPID for dosimetric verification of intensity-modulated radiotherapy, [J]. Chin J Radiol Med Prot, 26, 657
Gurjar, 2019, Craniospinal irradiation in medulloblastoma using high energy medical linear accelerator: An innovative approach to planning technique, Journal of Biomedical Physics, 9, 151
Jiménez-Melguizo, 2020, Response of the ArcCHECK device at 6 MV and 15 MV for VMAT and IMRT quality control, Physics Medical, 80, 373, 10.1016/j.ejmp.2020.11.020
Kry, 2019, Independent recalculation outperforms traditional measurement-based IMRT QA methods in detecting unacceptable plans, Medical Physics, 46, 3700, 10.1002/mp.13638
Laugeman, 2020, Comprehensive validation of halcyon 2.0 plans and the implementation of patient specific QA with multiple detector platforms, Journal of Applied Clinical Medical Physics, 21, 39, 10.1002/acm2.12881
Lee, 2015, Practical dose delivery verification of craniospinal IMRT, Journal of Applied Clinical Medical Physics, 16, 76, 10.1120/jacmp.v16i6.5481
Létourneau, 2009, Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy, Medical Physics, 36, 1813, 10.1118/1.3117563
2020, Clinical experience of intensity modulated radiotherapy pre-treatment quality assurance for carcinoma head and neck patients with EPID and IMatriXX in rural center, Journal of Biomedical Physics, 10, 691
Miften, 2018, Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218, Medical Physics, 45, e53, 10.1002/mp.12810
Nakaguchi, 2018, Commissioning and validation of fluence-based 3D VMAT dose reconstruction system using new transmission detector[ J], Radiol Phys Technol, 11, 165, 10.1007/s12194-018-0451-8
Newbold, 2006, Advanced imaging applied to radiotherapy planning in head and neck cancer: A clinical review, British Journal of Radiology, 79, 554, 10.1259/bjr/48822193
Sanghangthum, 2013, Statistical process control analysis for patient-specific IMRT and VMAT QA, Journal of Radiation Research, 54, 546, 10.1093/jrr/rrs112
Stambaugh, 2019, Improvements in treatment planning calculations motivated by tightening IMRT QA tolerances, Journal of Applied Clinical Medical Physics, 20, 250, 10.1002/acm2.12524
Wang, 2018, Correlation between gamma passing rate and complexity of IMRT plan due to MLC position errors, Physics Medical, 47, 112, 10.1016/j.ejmp.2018.03.003
Wu, 2016, Application of PTW729 and ArcCHECK detectors in dose verification of intensity modulated radiation therapy[J], Chinese Journal of Medical Physics, 33, 473
Yao, 2019, ArcCHECK for the verification of craniospinal irradiation with volumetric Modulated Arc Therapy[J], China Medical Equipment, 34, 44
Zou, 2015