Faciszewski, 1990, Subtle injuries of the Lisfranc joint, J Bone Joint Surg Am, 72, 1519, 10.2106/00004623-199072100-00013
Arntz, 1988, Fractures and fracture-dislocations of the tarsometatarsal joint, J Bone Joint Surg Am, 70, 173, 10.2106/00004623-198870020-00003
Myerson, 1986, Fracture dislocations of the tarsometatarsal joints: end results correlated with pathology and treatment, Foot Ankle, 6, 225, 10.1177/107110078600600504
Buzzard, 1998, Surgical management of acute tarsometatarsal fracture dislocation in the adult, Clin Orthop Relat Res, 125, 10.1097/00003086-199808000-00014
Schepers, 2013, Influence of approach and implant on reduction accuracy and stability in lisfranc fracture-dislocation at the tarsometatarsal joint, Foot Ankle Int, 34, 705, 10.1177/1071100712468581
Alberta, 2005, Ligamentous Lisfranc joint injuries: a biomechanical comparison of dorsal plate and transarticular screw fixation, Foot Ankle Int, 26, 462, 10.1177/107110070502600607
Hu, 2014, Outcome comparison of Lisfranc injuries treated through dorsal plate fixation versus screw fixation, Acta Ortop Bras, 22, 315, 10.1590/1413-78522014220600576
Hart, 2015, Can the use of variable-angle volar locking plates compensate for suboptimal plate positioning in unstable distal radius fractures? A biomechanical study, J Orthop Trauma, 29, e1, 10.1097/BOT.0000000000000146
Dipaola, 2008, Screw orientation and plate type (variable- vs. fixed-angle) effect strength of fixation for in vitro biomechanical testing of the Synthes CSLP, Spine J, 8, 717, 10.1016/j.spinee.2007.06.016
Stanbury, 2012, Biomechanical analysis of a volar variable-angle locking plate: the effect of capturing a distal radial styloid fragment, J Hand Surg Am, 37, 2488, 10.1016/j.jhsa.2012.09.009
Martineau, 2014, Biomechanical performance of variable and fixed angle locked volar plates for the dorsally comminuted distal radius, Iowa Orthop J, 34, 123
Huh, 2016, Reliability and validity of the korean version of the foot function index, J Foot Ankle Surg, 55, 759, 10.1053/j.jfas.2016.03.011
Budiman-Mak, 1991, The Foot Function Index: a measure of foot pain and disability, J Clin Epidemiol, 44, 561, 10.1016/0895-4356(91)90220-4
Goldstein, 2010, Comparison of different outcome instruments following foot and ankle trauma, Foot Ankle Int, 31, 1075, 10.3113/FAI.2010.1075
Farrar, 2001, Clinical importance of changes in chronic pain intensity measured on an 11-point numerical pain rating scale, Pain, 94, 149, 10.1016/S0304-3959(01)00349-9
Mehrzad, 2016, Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures, Ann Plast Surg, 77, 623, 10.1097/SAP.0000000000000850
Tank, 2016, Early mechanical failures of the synthes variable angle locking distal femur plate, J Orthop Trauma, 30, e7, 10.1097/BOT.0000000000000391
Court-Brown, 2006, Epidemiology of adult fractures: a review, Injury, 37, 691, 10.1016/j.injury.2006.04.130