Comparación entre el tonómetro de rebote IC200 y el tonómetro de aplanación Perkins en sujetos sanos y pacientes con glaucoma congénito

Archivos de la Sociedad Española de Oftalmología - Tập 96 - Trang 175-180 - 2021
P. Perez-Garcia1, L. Morales-Fernandez1, F. Saenz-Frances1, C.D. Mendez-Hernandez1, J. Garcia-Feijoo1, E. Santos-Bueso1, J.M. Martinez-de-la-Casa1
1Hospital Clínico San Carlos, Madrid, España

Tài liệu tham khảo

Beck, 2013, Definition classification differential diagnosis, 3 Arribas-Pardo, 2018, Icare-pro rebound tonometer versus handheld applanation tonometer for pediatric screening, J Pediatr Ophthalmol Strabismus, 55, 382, 10.3928/01913913-20180621-01 Lambert, 2013, Rebound tonometry in children, Ophthalmology, 120, e21, 10.1016/j.ophtha.2012.09.058 Molero-Senosiaín, 2019, Analysis of reproducibility, evaluation, and preference of the new iC100rebound tonometer versus iCare PRO and Perkins portable applanation tonometry, Eur J Ophthalmol, 30 Baskett, 1986, A comparison of Perkins and Goldmann applanation tonometry, J Am Optom Assoc, 57, 832 Moreno-Montañés, 2015, Clinical evaluation of the new rebound tonometers iCare PRO and iCare ONE compared with the Goldmann tonometer, J Glaucoma, 24, 527, 10.1097/IJG.0000000000000058 Martinez-de-la-Casa, 2005, Reproducibility and clinical evaluation of rebound tonometry, Invest Ophthalmol Vis Sci, 46, 4578, 10.1167/iovs.05-0586 Grigorian, 2015, Comparison of the Icare rebound tonometry with the Goldmann applanation tonometry in a pediatric population, J AAPOS, 19, 572, 10.1016/j.jaapos.2015.08.009 Mikhail, 2017, Effect of anesthesia on intraocular pressure measurement in children, Surv Ophthalmol, 62, 648, 10.1016/j.survophthal.2017.04.003 Dahlmann-Noor, 2013, Comparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: A cohort study, BMJ Open, 3, e001788, 10.1136/bmjopen-2012-001788 Borrego Sanz, 2016, The Icare-pro rebound tonometer versus the hand held applanation tonometer in congenital glaucoma, J Glaucoma, 25, 149, 10.1097/IJG.0000000000000177 Martinez-de-la-Casa, 2009, Comparison of rebound tonometer and Goldmann handheld applanation tonometer in congenital glaucoma, J Glaucoma, 18, 49, 10.1097/IJG.0b013e31816f760c Esmael, 2019, Agreement profiles for rebound and apllanation tonometry in normal and glaucomatous children, Eur J Ophthalmol, 29, 379, 10.1177/1120672118795060 Chan, 2015, Accuracy of intraocular pressure measurement with the Icare tonometer in children, Asia Pac J Ophthalmol, 4, 357, 10.1097/APO.0000000000000138 Badakere, 2019, Comparison of rebound tonometry and handheld applanation tonometry in pediatric glaucoma with clear and scarred corneas, Am J Ophthalmol, 126, 1330 Chen, 2019, Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group, BMC Ophthalmol, 19, 10.1186/s12886-019-1236-5 Ting, 2019, Comparison of Icare rebound tonometer and Perkins applanation tonometer in community eye screening, Asia Pac J Ophthalmol, 8, 229 Tamçelik, 2015, Comparability of Icare pro rebound tonometer with goldmann applanation and noncontact tonometer in a wide range of intraocular pressure and central corneal thickness, Ophthalmic Res, 54, 18, 10.1159/000381781 Nakakura, 2019, Comparison of the intraocular pressure measured using the new rebound tonometer Icare ic100and Icare TA01i or goldmann applanation tonometer, J Glaucoma, 28, 172, 10.1097/IJG.0000000000001138 Rao, 2014, Relationship of central corneal thickness and intraocular pressure by icare rebound tonometer, J Glaucoma, 23, 380, 10.1097/IJG.0b013e318279b819 Brown, 2018, The influence of corneal biomechanical properties on intraocular pressure measurements using a rebound self-tonometer, J Glaucoma, 27, 511, 10.1097/IJG.0000000000000948 Salvetat, 2011, Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty, Eye, 25, 642, 10.1038/eye.2011.60