Combined coronary artery bypass grafting and aortic valve replacement with minimal extracorporeal closed circuit circulation versus standard cardiopulmonary bypass

Interactive Cardiovascular and Thoracic Surgery - Tập 11 Số 6 - Trang 754-757 - 2010
Alaadin Yilmaz1, Jelena Sjatskig1, David Breen1, Frans G. Waanders2, Johannes C. Kelder3, Uday Sonker1
1Department of Cardiothoracic Surgery, St. Antonius Hospital, Koekoekslaan 1, P.O. Box 2500, 3430 EM Nieuwegein, The Netherlands.
2Department of Clinical Perfusion, St. Antonius Hospital, Nieuwegein, the Netherlands
3Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands

Tóm tắt

Từ khóa


Tài liệu tham khảo

Butler, 1993, Inflammatory response to cardiopulmonary bypass, Ann Thorac Surg, 55, 552, 10.1016/0003-4975(93)91048-R

Rothenburger, 2001, Prediction of clinical outcome after cardiac surgery: the role of cytokines, endotoxin, and anti-endotoxin core antibodies, Shock, 16, 44, 10.1097/00024382-200116001-00009

Fromes, 2002, Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation, Eur J Cardiothorac Surg, 22, 527, 10.1016/S1010-7940(02)00372-X

Remadi, 2004, Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial, J Thorac Cardiovasc Surg, 128, 436, 10.1016/j.jtcvs.2004.01.041

Wiesenack, 2004, Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome, Artif Organs, 28, 1082, 10.1111/j.1525-1594.2004.00030.x

van Boven, 2004, Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: a comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function, Perfusion, 19, 239, 10.1191/0267659104pf746oa

Castiglioni, 2009, Comparison of minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement: a randomized study, Interact CardioVasc Thorac Surg, 9, 37, 10.1510/icvts.2008.192559

Immer, 2007, Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting, Ann Thorac Surg, 84, 1515, 10.1016/j.athoracsur.2007.05.069

Castiglioni, 2007, Minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement, Ann Thorac Surg, 83, 586, 10.1016/j.athoracsur.2006.09.039

Remadi, 2006, Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra system or with a standard cardiopulmonary bypass, Am Heart J, 151, 198, 10.1016/j.ahj.2005.03.067