Coherent confocal microscope with a phase-only filter in its extended source
Tóm tắt
The phase information of an extended source is reconstructed by use of a two-zone (annular) phase-only filter in a coherent confocal scanning optical microscope. The dependence of its resolution on its source size is investigated theoretically by its three-dimensional optical transfer function (3D OTF). The results show that the resolution is improved, even though the source size is enlarged.
Tài liệu tham khảo
Drazic Valter,J. of Modern Optics,39 (1992), 1777.
M. A. A. Neil, R. Juskaitis, T. Wilson, Z. J. Laczik, and V. Sarafis,Optics Letters,25 (2000), 245.
I. Leiserson, S. G. Lipson, and V. Sarafis,Optics Letter,25 (2000), 209.
Daniel M. de Juana, Jos E. Oti, Vidal F. Canales, and Manuel P. Cagigal,Optics Letters,28 (2003), 607.
Z. S. Hegedus and V. Sarafis,J. Opt. Soc. Am. A,3 (1986), 1892.
Tasso R. M. Sales and G. Michael Morris,Optics Letters,22 (1997), 582.
Tasso R. M. Sales and G. Michael Morris,J. Opt. Soc. Am. A,14 (1997), 1637.
Daniel M. de Juana, Vidal F. Canales, Pedro J. Valle and Manuel P. Cagigal,Optics Communications,229 (2004), 71.
Hongping Ding, Qinghui, Li and Wenyi Zou,Optics Communications,229 (2004), 117.
Ding Hongping, Li Qinghui, and Zou Wenyi,J. of Optoelectronics · Laser,15 (2004), 18. (in Chinese)
Wang Xianghui, Lin Lie, and Yang Yong,J. of Optoelectronics · Laser,15 (2004), 420. (in Chinese)
Ding Hongping, Li Qinghui andZou Wenyi, J. of Optoelectronics · Laser 15 (2004), 1311. (in Chinese)