Clinical Outcomes After SMILE and Femtosecond Laser-Assisted LASIK for Myopia and Myopic Astigmatism

Cornea - Tập 35 Số 2 - Trang 210-216 - 2016
Manli Liu1, Yile Chen1, Danyang Wang1, Yugui Zhou1, Xiaoying Zhang1, Jiexu He1, Ting Zhang1, Yuan Sun1, Quan Liu1
1Refractive Surgery Center, State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.

Tóm tắt

Từ khóa


Tài liệu tham khảo

Ratkay-Traub, 2001, . Ultra-short pulse (femtosecond) laser surgery: initial use in LASIK flap creation., Ophthalmol Clin North Am, 14, 347

Kymionis, 2012, . Femtosecond laser technology in corneal refractive surgery: a review., J Refract Surg, 28, 912, 10.3928/1081597X-20121116-01

Tanna, 2009, Femtosecond laser versus mechanical microkeratome: a retrospective comparison of visual outcomes at 3 months., J Refract Surg, 25, S668, 10.3928/1081597X-20090611-08

Montes-Mico, 2007, Femtosecond laser versus mechanical keratome LASIK for myopia., Ophthalmology, 114, 62, 10.1016/j.ophtha.2006.07.019

Sekundo, 2011, Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study., Br J Ophthalmol, 95, 335, 10.1136/bjo.2009.174284

Vestergaard, 2012, . Small-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfaction., J Cataract Refract Surg, 38, 2003, 10.1016/j.jcrs.2012.07.021

Kamiya, 2014, . Visual and refractive outcomes of femtosecond lenticule extraction and small-incision lenticule extraction for myopia., Am J Ophthalmol, 157, 128, 10.1016/j.ajo.2013.08.011

Ivarsen, 2014, Safety and complications of more than 1500 small-incision lenticule extraction procedures., Ophthalmology, 121, 822, 10.1016/j.ophtha.2013.11.006

Li, 2013, . Confocal comparison of corneal reinnervation after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK)., PLoS One, 8, e81435, 10.1371/journal.pone.0081435

Denoyer, 2015, . Dry eye disease after refractive surgery: comparative outcomes of small incision lenticule extraction versus LASIK., Ophthalmology, 122, 669, 10.1016/j.ophtha.2014.10.004

Xu, 2015, Small-incision lenticule extraction for myopia: results of a 12-Month prospective study., Optom Vis Sci, 92, 123, 10.1097/OPX.0000000000000451

Sekundo, 2014, . One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE)., Graefes Arch Clin Exp Ophthalmol, 252, 837, 10.1007/s00417-014-2608-4

Kunert, 2015, . One-year results of small incision lenticule extraction (SMILE) in myopia in German., Klin Monbl Augenheilkd, 232, 67

Lin, 2014, Comparison of the visual results after SMILE and femtosecond laser-assisted LASIK for myopia., J Refract Surg, 30, 248, 10.3928/1081597X-20140320-03

Ganesh, 2014, Comparison of visual and refractive outcomes following femtosecond laser- assisted lasik with smile in patients with myopia or myopic astigmatism., J Refract Surg, 30, 590, 10.3928/1081597X-20140814-02

Alpins, 2001, Astigmatism analysis by the Alpins method., J Cataract Refract Surg, 27, 31, 10.1016/S0886-3350(00)00798-7

Shah, 2011, Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery., J Cataract Refract Surg, 37, 127, 10.1016/j.jcrs.2010.07.033

Vestergaard, 2013, . Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx((R)) flex and comparison with a retrospective study of FS-laser in situ keratomileusis., Acta Ophthalmol, 91, 355, 10.1111/j.1755-3768.2012.02406.x

Heichel, 2011, . Surface quality of porcine corneal lenticules after Femtosecond Lenticule Extraction., Ophthalmic Res, 46, 107, 10.1159/000323814

Shah, 2011, Effect of scanning patterns on the results of femtosecond laser lenticule extraction refractive surgery., J Cataract Refract Surg, 37, 1636, 10.1016/j.jcrs.2011.03.056

Agca, 2014, . Corneal backscatter analysis by in vivo confocal microscopy: fellow eye comparison of small incision lenticule extraction and femtosecond laser-assisted LASIK., J Ophthalmol, 2014, 265012, 10.1155/2014/265012

Vestergaard, 2014, . Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction., J Cataract Refract Surg, 40, 403, 10.1016/j.jcrs.2013.07.053

Gyldenkerne, 2015, Comparison of corneal shape changes and aberrations induced by FS-LASIK and SMILE for myopia., J Refract Surg, 31, 223, 10.3928/1081597X-20150303-01

Vega-Estrada, 2012, . Corneal higher order aberrations after LASIK for high myopia with a fast repetition rate excimer laser, optimized ablation profile, and femtosecond laser-assisted flap., J Refract Surg, 28, 689, 10.3928/1081597X-20120921-03

Buhren, 2005, Influence of pupil and optical zone diameter on higher-order aberrations after wavefront-guided myopic LASIK., J Cataract Refract Surg, 31, 2272, 10.1016/j.jcrs.2005.10.023

Mok, 2005, Effect of optical zone ablation diameter on LASIK-induced higher order optical aberrations., J Refract Surg, 21, 141, 10.3928/1081-597X-20050301-07

Dong, 2014, . Small incision lenticule extraction (SMILE) and femtosecond laser LASIK: comparison of corneal wound healing and inflammation., Br J Ophthalmol, 98, 263, 10.1136/bjophthalmol-2013-303415

Zhao, 2015, . Development of the continuous curvilinear lenticulerrhexis technique for small incision lenticule extraction., J Refract Surg, 31, 16, 10.3928/1081597X-20141218-02