Chronic Arterial Responses to Overlapping Paclitaxel-Eluting Stents

JACC: Cardiovascular Interventions - Tập 1 - Trang 161-167 - 2008
Jiro Aoki1, Gary S. Mintz1, Neil J. Weissman2, J. Tift Mann3, Louis Cannon4, Joel Greenberg5, Eberhard Grube6, A.R. Zaki Masud7, Joerg Koglin8, Lazar Mandinov8, Gregg W. Stone1
1Columbia University Medical Center and Cardiovascular Research Foundation, New York, New York.
2Cardiovascular Research Institute, Washington Hospital Center, Washington DC
3Wake Heart Research, Raleigh, North Carolina
4Cardiac & Vascular Research Center of Northern Michigan, Petoskey, Michigan
5Florida Heart Institute, Orlando, Florida
6Helios Klinikum, Siegburg, Germany
7Buffalo General Hospital, Buffalo, New York
8Boston Scientific Corp., Natick, Massachusetts.

Tài liệu tham khảo

Stone, 2004, A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease, N Engl J Med, 350, 221, 10.1056/NEJMoa032441 Stone, 2005, Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial, JAMA, 294, 1215, 10.1001/jama.294.10.1215 Stone, 2006, Paclitaxel-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the TAXUS V ISR randomized trial, JAMA, 295, 1253, 10.1001/jama.295.11.1253 Abizaid, 2006, Twelve-month outcomes with a paclitaxel-eluting stent transitioning from controlled trials to clinical practice (the WISDOM Registry), Am J Cardiol, 98, 1028, 10.1016/j.amjcard.2006.05.020 Colombo, 2003, Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions, Circulation, 108, 788, 10.1161/01.CIR.0000086926.62288.A6 Dawkins, 2005, Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: support for the use of drug-eluting stents in contemporary clinical practice, Circulation, 112, 3306, 10.1161/CIRCULATIONAHA.105.552190 Finn, 2005, Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents, Circulation, 112, 270, 10.1161/CIRCULATIONAHA.104.508937 Wilson, 2007, Overlapping paclitaxel-eluting stents: long-term effects in a porcine coronary artery model, Cardiovasc Res, 76, 361, 10.1016/j.cardiores.2007.07.004 Chu, 2006, Comparison of clinical outcomes of overlapping sirolimus- versus paclitaxel-eluting stents in patients undergoing percutaneous coronary intervention, Am J Cardiol, 98, 1563, 10.1016/j.amjcard.2006.07.032 Aoki, 2005, “Full metal jacket” (stented length > or =64 mm) using drug-eluting stents for de novo coronary artery lesions, Am Heart J, 150, 994, 10.1016/j.ahj.2005.01.050 Weissman, 2007, Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials, Eur Heart J, 28, 1574, 10.1093/eurheartj/ehm174 Mintz, 2006, Intravascular ultrasound in the drug-eluting stent era, J Am Coll Cardiol, 48, 421, 10.1016/j.jacc.2006.04.068 Aoki, 2005, Peristent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation: insights from serial intravascular ultrasound analysis in the TAXUS II study, Circulation, 112, 3876, 10.1161/CIRCULATIONAHA.105.558601 Tanabe, 2004, Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-II trial, Circulation, 109, 196, 10.1161/01.CIR.0000109137.51122.49 Mintz, 2001, A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents, J Am Coll Cardiol, 37, 1478, 10.1016/S0735-1097(01)01175-5 Petronio, 2007, Randomized comparison of sirolimus and paclitaxel drug-eluting stents for long lesions in the left anterior descending artery: an intravascular ultrasound study, J Am Coll Cardiol, 49, 539, 10.1016/j.jacc.2006.09.042 Mintz, 2003, Circulation, 108, 1295, 10.1161/01.CIR.0000091254.73351.D6 Minutello, 2006, Angiographic pattern of restenosis following implantation of overlapping sirolimus-eluting (Cypher) stents, Am J Cardiol, 97, 499, 10.1016/j.amjcard.2005.09.082 Burzotta, 2007, Outcome of overlapping heterogenous drug-eluting stents and of overlapping drug-eluting and bare metal stents, Am J Cardiol, 99, 364, 10.1016/j.amjcard.2006.08.039 Kang, 2007, Angiographic and intravascular ultrasound study of the effects of overlapping sirolimus- and paclitaxel-eluting stents: comparison with same drug-eluting overlapping stents, Int J Cardiol, 123, 12, 10.1016/j.ijcard.2006.11.104 Kawaguchi, 2008, Angiographic and 3D intravascular ultrasound assessment of overlapping bare metal stent and three different formulations of drug-eluting stents in patients with diabetes mellitus, Int J Cardiovasc Imaging, 24, 125, 10.1007/s10554-007-9235-7 Ichikawa, 2007, Angioscopic findings of delayed healing at sites of sirolimus-eluting stent overlap after 21-month implantation, Int J Cardiol Weissman, 2005, Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: a serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial, J Am Coll Cardiol, 45, 1201, 10.1016/j.jacc.2004.10.078 Schwartz, 2006, Cypher versus Taxus stents: comparing inflammatory response in porcine coronary arteries, Am J Cardiol, 98 Pires, 2007, Sirolimus and paclitaxel provoke different vascular pathological responses after local delivery in a murine model for restenosis on underlying atherosclerotic arteries, Heart, 93, 922, 10.1136/hrt.2006.102244 Serruys, 2002, Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial, Circulation, 106, 798, 10.1161/01.CIR.0000025585.63486.59 Balakrishnan, 2005, Strut position, blood flow, and drug deposition: implications for single and overlapping drug-eluting stents, Circulation, 111, 2958, 10.1161/CIRCULATIONAHA.104.512475 Farb, 1999, Pathology of acute and chronic coronary stenting in humans, Circulation, 99, 44, 10.1161/01.CIR.99.1.44 Farb, 2002, Morphological predictors of restenosis after coronary stenting in humans, Circulation, 105, 2974, 10.1161/01.CIR.0000019071.72887.BD Finn, 2007, Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization, Circulation, 115, 2435, 10.1161/CIRCULATIONAHA.107.693739 Nicholls, 2006, Intravascular ultrasound in cardiovascular medicine, Circulation, 114, e55, 10.1161/CIRCULATIONAHA.106.637942 Schoenhagen, 2006, Determinants of arterial wall remodeling during lipid-lowering therapy: serial intravascular ultrasound observations from the Reversal of Atherosclerosis with Aggressive Lipid Lowering Therapy (REVERSAL) trial, Circulation, 113, 2826, 10.1161/CIRCULATIONAHA.105.585703 Nissen, 2004, Effect of antihypertensive agents on cardiovascular events in patients with coronary disease and normal blood pressure: the CAMELOT study: a randomized controlled trial, JAMA, 292, 2217, 10.1001/jama.292.18.2217 Okazaki, 2004, Early statin treatment in patients with acute coronary syndrome: demonstration of the beneficial effect on atherosclerotic lesions by serial volumetric intravascular ultrasound analysis during half a year after coronary event: the ESTABLISH Study, Circulation, 110, 1061, 10.1161/01.CIR.0000140261.58966.A4