Characterizing deep brain biosignals: The advances and applications of implantable MEMS-based devices

Materials Today Advances - Tập 16 - Trang 100322 - 2022
Hsin-Yu Wu1,2, Kao-Jung Chang1,2,3, Ximiao Wen4, Aliaksandr A. Yarmishyn2, He-Jhen Dai1,2, Kai-Hsiang Chan1, Hsiao Yu-Jer1,2, Ming-Teh Chen1,5, Yueh Chien6,7, Hsin-I Ma8, Wensyang Hsu9, Meng-Shiue Lee2,6, Shih-Hwa Chiou1,2,3,6,7
1School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
2Department of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
3Institute of Clinical Medicine, National Yang-Ming Chiao Tung University, Taipei, Taiwan, ROC
4Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, California, USA
5Department of Neurosurgery, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
6Institute of Pharmacology, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
7Department of Medical Research and Education, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
8Department of Neurological Surgery, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan, ROC
9Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan, ROC

Tài liệu tham khảo

Yizhar, 2011, Optogenetics in neural systems, Neuron, 71, 9, 10.1016/j.neuron.2011.06.004 Robinson, 2008, Monitoring rapid chemical communication in the brain, Chem. Rev., 108, 2554, 10.1021/cr068081q Mariani, 2005, Oxidative stress in brain aging, neurodegenerative and vascular diseases: an overview, J. Chromatogr. B, 827, 65, 10.1016/j.jchromb.2005.04.023 Timofeev, 2011, Interaction between brain chemistry and physiology after traumatic brain injury: impact of autoregulation and microdialysis catheter location, J. Neurotrauma, 28, 849, 10.1089/neu.2010.1656 de Hoyos, A., et al., Improving the Spatial Resolution of Magnetoencephalography Images. Proudfoot, 2014, Magnetoencephalography, Practical neurology, 14, 336, 10.1136/practneurol-2013-000768 Singh, 2014, Magnetoencephalography: basic principles, Ann. Indian Acad. Neurol., 17, S107, 10.4103/0972-2327.128676 Glover, 2011, Overview of functional magnetic resonance imaging, Neurosurgery Clinics, 22, 133 Shmuel, 2007, Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla, Neuroimage, 35, 539, 10.1016/j.neuroimage.2006.12.030 Manfrinato, 2013, Resolution limits of electron-beam lithography toward the atomic scale, Nano Lett., 13, 1555, 10.1021/nl304715p Kipke, 2008, Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities, J. Neurosci., 28, 10.1523/JNEUROSCI.3879-08.2008 Najafi, 1986, An implantable multielectrode array with on-chip signal processing, IEEE J. Solid State Circ., 21, 1035, 10.1109/JSSC.1986.1052646 Michael McKinley, D., Human Anatomy third ed.. Ingram, Place. Günter, 2019, Safety of long-term electrical peripheral nerve stimulation: review of the state of the art, J. NeuroEng. Rehabil., 16, 1 Holubec, 2015, Does implantation technique influence lead failure?, Acta Cardiol., 70, 581, 10.1080/AC.70.5.3110519 Révész, 2016, Complications and safety of vagus nerve stimulation: 25 years of experience at a single center, J. Neurosurg. Pediatr., 18, 97, 10.3171/2016.1.PEDS15534 Ordonez, 2012, A 232-channel retinal vision prosthesis with a miniaturized hermetic package, 2796 Du, 2017, Ultrasoft microwire neural electrodes improve chronic tissue integration, Acta Biomater., 53, 46, 10.1016/j.actbio.2017.02.010 Biran, 2005, Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays, Exp. Neurol., 195, 115, 10.1016/j.expneurol.2005.04.020 Claverol-Tinture, 2004, Intersection of microwire electrodes with proximal CA1 stratum-pyramidale neurons at insertion for multiunit recordings predicted by a 3-D computer model, IEEE Trans. Biomed. Eng., 51, 2211, 10.1109/TBME.2004.834274 Wen, 2019, Flexible, multifunctional neural probe with liquid metal enabled, ultra-large tunable stiffness for deep-brain chemical sensing and agent delivery, Biosens. Bioelectron., 131, 37, 10.1016/j.bios.2019.01.060 Jorfi, 2014, Progress towards biocompatible intracortical microelectrodes for neural interfacing applications, J. Neural. Eng., 12 Chen, 2017, Neural recording and modulation technologies, Nat. Rev. Mater., 2, 1, 10.1038/natrevmats.2016.93 Polikov, 2005, Response of brain tissue to chronically implanted neural electrodes, J. Neurosci. Methods, 148, 1, 10.1016/j.jneumeth.2005.08.015 Reichert, 2007 Kim, 2004, Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices, J. Biomed. Mater. Res. Part A: Off J of The Society for Biom, 71, 577, 10.1002/jbm.a.30124 Zhou, 2020, Ultra-flexible neural probes with electrochemical modified electrodes for reliable, chronical recording, 416 Decharms, 1999, A multielectrode implant device for the cerebral cortex, J. Neurosci. Methods, 93, 27, 10.1016/S0165-0270(99)00087-4 Seymour, 2011, Novel multi-sided, microelectrode arrays for implantable neural applications, Biomed. Microdevices, 13, 441, 10.1007/s10544-011-9512-z Ginggen, 2008, A telemetric pressure sensor system for biomedical applications, IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng., 55, 1374 McAlinden, 2013, Thermal and optical characterization of micro-LED probes for in vivo optogenetic neural stimulation, Opt. Lett., 38, 992, 10.1364/OL.38.000992 Chen, 2013, A fiber-based implantable multi-outrode array with contiguous optical and electrical sites, J. Neural. Eng., 10, 10.1088/1741-2560/10/4/046020 McConnell, 2009, Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration, J. Neural. Eng., 6, 10.1088/1741-2560/6/5/056003 Tsui, 2019, Biomaterials and glia: progress on designs to modulate neuroinflammation, Acta Biomater., 83, 13, 10.1016/j.actbio.2018.11.008 Zhang, 2022, Down-regulating scar formation by microneedles directly via a mechanical communication pathway, ACS Nano, 16, 10163, 10.1021/acsnano.1c11016 Zhang, 2015, Anti-fouling coatings of poly (dimethylsiloxane) devices for biological and biomedical applications, J. Med. Biol. Eng., 35, 143, 10.1007/s40846-015-0029-4 Zhou, 2010, Recent developments in PDMS surface modification for microfluidic devices, Electrophoresis, 31, 2, 10.1002/elps.200900475 Boehler, 2017, Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study, Biomaterials, 129, 176, 10.1016/j.biomaterials.2017.03.019 He, 2007, A novel anti-inflammatory surface for neural electrodes, Adv. Mater., 19, 3529, 10.1002/adma.200700943 Zhong, 2007, Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes, Brain Res., 1148, 15, 10.1016/j.brainres.2007.02.024 Kennedy, 1989, The cone electrode: a long-term electrode that records from neurites grown onto its recording surface, J. Neurosci. Methods, 29, 181, 10.1016/0165-0270(89)90142-8 He, 2006, Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays, J. Neural. Eng., 3, 316, 10.1088/1741-2560/3/4/009 Das, 2020, Biointegrated and wirelessly powered implantable brain devices: a review, IEEE Transactions on Biomedical Circuits and Systems, 14, 343, 10.1109/TBCAS.2020.2966920 Tamura, 2008, Analysis of traumatic brain injury due to primary head contact during vehicle-to-pedestrian impact, Int. J. Crashworthiness, 13, 375, 10.1080/13588260802030497 Lindén, 2010, Intrinsic dendritic filtering gives low-pass power spectra of local field potentials, J. Comput. Neurosci., 29, 423, 10.1007/s10827-010-0245-4 Im, 2016, A review of electrodes for the electrical brain signal recording, Biomedical Engineering Letters, 6, 104, 10.1007/s13534-016-0235-1 Chen, 2019, Automatic diagnosis of epileptic seizure in electroencephalography signals using nonlinear dynamics features, IEEE Access, 7 Milikovsky, 2017, Electrocorticographic dynamics as a novel biomarker in five models of epileptogenesis, J. Neurosci., 37, 4450, 10.1523/JNEUROSCI.2446-16.2017 Rajdev, 2010, Real-time seizure prediction from local field potentials using an adaptive Wiener algorithm, Comput. Biol. Med., 40, 97, 10.1016/j.compbiomed.2009.11.006 Murray, 2012, Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010, Lancet, 380, 2197, 10.1016/S0140-6736(12)61689-4 Acharya, 2012, Automated diagnosis of epileptic EEG using entropies, Biomed. Signal Process Control, 7, 401, 10.1016/j.bspc.2011.07.007 Han, 2013, Investigation of EEG abnormalities in the early stage of Parkinson’s disease, Cognitive neurodynamics, 7, 351, 10.1007/s11571-013-9247-z Dauwels, 2011, Slowing and loss of complexity in Alzheimer's EEG: two sides of the same coin?, Int. J. Alzheimer's Dis., 10.4061/2011/539621 Poil, 2013, Integrative EEG biomarkers predict progression to Alzheimer's disease at the MCI stage, Front. Aging Neurosci., 5, 58, 10.3389/fnagi.2013.00058 Murtha, 2015, Intracranial pressure elevation after ischemic stroke in rats: cerebral edema is not the only cause, and short-duration mild hypothermia is a highly effective preventive therapy, J. Cerebr. Blood Flow Metabol., 35, 592, 10.1038/jcbfm.2014.230 Rahman, 2016 Green, 1961, Asymmetries of beta activity in epilepsy, brain tumor, and cerebrovascular disease, Electroencephalogr. Clin. Neurophysiol., 13, 75, 10.1016/0013-4694(61)90077-3 Rangaswamy, 2002, Beta power in the EEG of alcoholics, Biol. Psychiatr., 52, 831, 10.1016/S0006-3223(02)01362-8 Kazemi, 2022, Sleep staging using semi-unsupervised clustering of EEG: application to REM sleep behavior disorder, Biomed. Signal Process Control, 75, 10.1016/j.bspc.2022.103539 Kalas, 2016, Stress detection and reduction using EEG signals, 471 Deng, 2020, Detecting fatigue status of pilots based on deep learning network using EEG signals, IEEE Transactions on Cognitive and Developmental Systems, 13, 575 Krishna, 2019 Li, 2010, An EEG-based BCI system for 2-D cursor control by combining Mu/Beta rhythm and P300 potential, IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng., 57, 2495 Steinisch, 2013, A post-stroke rehabilitation system integrating robotics, VR and high-resolution EEG imaging, IEEE Trans. Neural Syst. Rehabil. Eng., 21, 849, 10.1109/TNSRE.2013.2267851 Oyster, 1982, Analysis of neuronal soma size distributions, J. Neurosci. Methods, 6, 311, 10.1016/0165-0270(82)90032-2 Liewald, 2014, Distribution of axon diameters in cortical white matter: an electron-microscopic study on three human brains and a macaque, Biol. Cybern., 108, 541, 10.1007/s00422-014-0626-2 Savtchenko, 2007, The optimal height of the synaptic cleft, Proc. Natl. Acad. Sci. USA, 104, 1823, 10.1073/pnas.0606636104 Manghisoni, 2006, Noise characterization of 130 nm and 90 nm CMOS technologies for analog front-end electronics, vol. 1, 214 Re, 2004, Survey of noise performances and scaling effects in deep submicron CMOS devices from different foundries, vol. 3, 1368 Fallegger, 2021, MRI-compatible and conformal electrocorticography grids for translational research, Adv. Sci., 8, 10.1002/advs.202003761 Telkes, 2020, Functional use of directional local field potentials in the subthalamic nucleus deep brain stimulation, Front. Hum. Neurosci., 14, 145, 10.3389/fnhum.2020.00145 Baek, 2014, A thin film polyimide mesh microelectrode for chronic epidural electrocorticography recording with enhanced contactability, J. Neural. Eng., 11, 10.1088/1741-2560/11/4/046023 Ware, 2014, Thiol-ene/acrylate substrates for softening intracortical electrodes, J. Biomed. Mater. Res. B Appl. Biomater., 102, 1, 10.1002/jbmb.32946 Kelly, 2003, Advantages and disadvantages of patch clamping versus using BLM, vol. 7, 699 Verkhratsky, 2014, History of electrophysiology and the patch clamp, 1 Hodgkin, 1952, Measurement of current-voltage relations in the membrane of the giant axon of Loligo, J. Physiol., 116, 424, 10.1113/jphysiol.1952.sp004716 Harvey, 2009, Intracellular dynamics of hippocampal place cells during virtual navigation, Nature, 461, 941, 10.1038/nature08499 Gray, 1995, Tetrodes markedly improve the reliability and yield of multiple single-unit isolation from multi-unit recordings in cat striate cortex, J. Neurosci. Methods, 63, 43, 10.1016/0165-0270(95)00085-2 Seymour, 2017, State-of-the-art MEMS and microsystem tools for brain research, Microsystems & Nanoengineering, 3, 1, 10.1038/micronano.2016.66 Rivnay, 2017, Next-generation probes, particles, and proteins for neural interfacing, Sci. Adv., 3, 10.1126/sciadv.1601649 Zátonyi, 2019, A softening laminar electrode for recording single unit activity from the rat hippocampus, Sci. Rep., 9, 1, 10.1038/s41598-019-39835-6 Ware, 2012, Fabrication of responsive, softening neural interfaces, Adv. Funct. Mater., 22, 3470, 10.1002/adfm.201200200 Liu, 2015, Syringe-injectable electronics, Nat. Nanotechnol., 10, 629, 10.1038/nnano.2015.115 Xie, 2015, Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes, Nat. Mater., 14, 1286, 10.1038/nmat4427 Fu, 2017, Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology, Proc. Natl. Acad. Sci. USA, 114, 10.1073/pnas.1717695114 Rousche, 2001, Flexible polyimide-based intracortical electrode arrays with bioactive capability, IEEE Trans. Biomed. Eng., 48, 361, 10.1109/10.914800 Muthuswamy, 2005, An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents, IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng., 52, 1470 Jackson, 2010, Long-term neural recordings using MEMS based moveable microelectrodes in the brain, Front. Neuroeng., 3, 10 Revyn, 2022, Recording neuronal activity on chip with segmented 3D microelectrode arrays, 102 Williams, 1999, Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex, Brain Res. Protoc., 4, 303, 10.1016/S1385-299X(99)00034-3 Venkatachalam, 1999, Ultra-miniature headstage with 6-channel drive and vacuum-assisted micro-wire implantation for chronic recording from the neocortex, J. Neurosci. Methods, 90, 37, 10.1016/S0165-0270(99)00065-5 Simon, 2017, Design and demonstration of an intracortical probe technology with tunable modulus, J. Biomed. Mater. Res., 105, 159, 10.1002/jbm.a.35896 Green, 2015, Conducting polymers for neural prosthetic and neural interface applications, Adv. Mater., 27, 7620, 10.1002/adma.201501810 Aregueta-Robles, 2014, Organic electrode coatings for next-generation neural interfaces, Front. Neuroeng., 7, 15, 10.3389/fneng.2014.00015 Fattahi, 2014, A review of organic and inorganic biomaterials for neural interfaces, Adv. Mater., 26, 1846, 10.1002/adma.201304496 Fee, 2001, Miniature motorized microdrive and commutator system for chronic neural recording in small animals, J. Neurosci. Methods, 112, 83, 10.1016/S0165-0270(01)00426-5 Kim, 2010, Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics, Nat. Mater., 9, 511, 10.1038/nmat2745 Rousche, 1998, Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex, J. Neurosci. Methods, 82, 1, 10.1016/S0165-0270(98)00031-4 Kennedy, 1998, Restoration of neural output from a paralyzed patient by a direct brain connection, Neuroreport, 9, 1707, 10.1097/00001756-199806010-00007 Obenaus, 2016, Traumatic brain injury Chang, 2013, A wireless and batteryless microsystem with implantable grid electrode/3-dimensional probe array for ECoG and extracellular neural recording in rats, Sensors, 13, 4624, 10.3390/s130404624 Wilson, 2003, A microelectrode drive for long term recording of neurons in freely moving and chaired monkeys, J. Neurosci. Methods, 127, 49, 10.1016/S0165-0270(03)00122-5 Walters, 1998, Intracranial pressure and cerebral blood flow, Physiology, 8, 1 Ng, 2004, Effects of head posture on cerebral hemodynamics: its influences on intracranial pressure, cerebral perfusion pressure, and cerebral oxygenation, Neurosurgery, 54, 593, 10.1227/01.NEU.0000108639.16783.39 Pedersen, 2018, The relationship between intracranial pressure and age—chasing age-related reference values, World Neurosurgery, 110, e119, 10.1016/j.wneu.2017.10.086 Zoerle, 2015, Intracranial pressure after subarachnoid hemorrhage, Crit. Care Med., 43, 168, 10.1097/CCM.0000000000000670 Janny, 1978, Intracranial pressure with intracerebral hemorrhages, Surg. Neurol., 10, 371 Zierski, 1987, Blood flow in brain structures during increased ICP, 95 Kirshner, 2008, Medical management of intracerebral haemorrhage: back to the basics, Int. J. Clin. Pract., 62, 521, 10.1111/j.1742-1241.2008.01708.x Anderson, 2013, Rapid blood-pressure lowering in patients with acute intracerebral hemorrhage, N. Engl. J. Med., 368, 2355, 10.1056/NEJMoa1214609 Malhotra, 2017, Cerebral microhemorrhages and meningeal siderosis in infective endocarditis, Cerebrovasc. Dis., 43, 59, 10.1159/000452718 Institute, 1988 Aaslid, 1982, Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries, J. Neurosurg., 57, 769, 10.3171/jns.1982.57.6.0769 Ragauskas, 2005, Innovative non-invasive method for absolute intracranial pressure measurement without calibration, 357 Alperin, 2000, MR-Intracranial pressure (ICP): a method to measure intracranial elastance and pressure noninvasively by means of MR imaging: baboon and human study, Radiology, 217, 877, 10.1148/radiology.217.3.r00dc42877 Zweifel, 2010, Noninvasive monitoring of cerebrovascular reactivity with near infrared spectroscopy in head-injured patients, J. Neurotrauma, 27, 1951, 10.1089/neu.2010.1388 Lang, 2003, Noninvasive intracranial compliance monitoring: technical note and clinical results, J. Neurosurg., 98, 214, 10.3171/jns.2003.98.1.0214 Geeraerts, 2007, Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury, Intensive Care Med., 33, 1704, 10.1007/s00134-007-0797-6 Donald, 1984, Further studies with a noninvasive method of intracranial pressure estimation, Neurosurgery, 14, 456, 10.1097/00006123-198404000-00011 Chen, 2012, A new method of intracranial pressure monitoring by EEG power spectrum analysis, Can. J. Neurol. Sci., 39, 483, 10.1017/S0317167100013998 Papo, 1982, External ventricular drainage in the management of posterior fossa tumors in children and adolescents, Neurosurgery, 10, 13, 10.1227/00006123-198201000-00002 Fernandes, 1998, Clinical evaluation of the Codman microsensor intracranial pressure monitoring system, 44 Sarrafzadeh, 2014, Guided (VENTRI-GUIDE) versus freehand ventriculostomy: study protocol for a randomized controlled trial, Trials, 15, 1, 10.1186/1745-6215-15-478 Kasotakis, 2012, Intraparenchymal vs extracranial ventricular drain intracranial pressure monitors in traumatic brain injury: less is more?, J. Am. Coll. Surg., 214, 950, 10.1016/j.jamcollsurg.2012.03.004 Bekar, 2009, Risk factors and complications of intracranial pressure monitoring with a fiberoptic device, J. Clin. Neurosci., 16, 236, 10.1016/j.jocn.2008.02.008 Ghannad-Rezaie, 2011, A near-infrared optomechanical intracranial pressure microsensor, J. Microelectromech. Syst., 21, 23, 10.1109/JMEMS.2011.2171322 Shin, 2019, Bioresorbable optical sensor systems for monitoring of intracranial pressure and temperature, Sci. Adv., 5, 10.1126/sciadv.aaw1899 Li, 2010, Dual-mode operation of flexible piezoelectric polymer diaphragm for intracranial pressure measurement, Appl. Phys. Lett., 96 Chan, 2014, A monolithically integrated pressure/oxygen/temperature sensing SoC for multimodality intracranial neuromonitoring, IEEE J. Solid State Circ., 49, 2449, 10.1109/JSSC.2014.2345754 Kalpana, 2021, Design and analysis of intracranial pressure sensor with liquid crystal polymer for sensitivity enhancement, Annals of the Romanian Society for Cell Biology Liew, 2000, Disposable CMOS catheter-tip pressure sensor for intracranial pressure measurement, 130 Bo, 2013, Simulation and design of micro pressure sensors applied to measure the intracranial pressure, 120 Zhang, 2014, Tiny MEMS-based pressure sensors in the measurement of Intracranial Pressure, Tsinghua Sci. Technol., 19, 161, 10.1109/TST.2014.6787369 Meng, 2014, Packaging a piezoresistive pressure sensor for intracranial pressure monitoring, 1827 Ntziachristos, 2005, Looking and listening to light: the evolution of whole-body photonic imaging, Nat. Biotechnol., 23, 313, 10.1038/nbt1074 Hill, 2007, SU-8 MEMS Fabry-Perot pressure sensor, Sensor Actuator Phys., 138, 52, 10.1016/j.sna.2007.04.047 Niu, 2014, Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity, Rev. Sci. Instrum., 85, 10.1063/1.4856455 Zhang, 2007, A novel pressure microsensor with 30-$∖mu∖hbox {m} $-thick diaphragm and meander-shaped piezoresistors partially distributed on high-stress bulk silicon region, IEEE Sensor. J., 7, 1742, 10.1109/JSEN.2007.910298 Kubba, 2016, A micro-capacitive pressure sensor design and modelling, Journal of Sensors and Sensor Systems, 5, 95, 10.5194/jsss-5-95-2016 Liu, 2015, Micro packaged MEMS pressure sensor for intracranial pressure measurement, J. Semiconduct., 36 Mohamad, 2016, Design of a high sensitivity MEMS piezoresistive intracranial pressure sensor using three turns meander shaped piezoresistors, 1 Mohamad, 2020, Effect of different wheatstone bridge configurations on sensitivity and linearity of MEMS piezoresistive intracranial pressure sensors, Journal of Electronic Voltage and Application, 1, 14 Rahman, 2016, Design of graphene-based MEMS intracranial pressure sensor, 1 Rahman, 2018, Load deflection analysis of rectangular graphene diaphragm for MEMS intracranial pressure sensor applications, Microsyst. Technol., 24, 1147, 10.1007/s00542-017-3477-7 Kavitha, 2021, Design and simulation analysis of membrane based mems piezoresistive pressure sensor for intracranial pressure measurements, Annals of the Romanian Society for Cell Biology, 609 Kalaiyazhagan, 2019, MEMS sensor-based cantilever for intracranial pressure measurement, 127 Mohamad, 2018, Design optimisation of high sensitivity MEMS piezoresistive intracranial pressure sensor using Taguchi approach, Microsyst. Technol., 24, 2637, 10.1007/s00542-017-3699-8 Sattayasoonthorn, 2013, LCP MEMS implantable pressure sensor for Intracranial Pressure measurement, 63 Wu, 2013, A new intracranial pressure sensor on polyimide lab-on-a-tube using exchanged polysilicon piezoresistors, 1779 Masenelli-Varlot, 2002, Mechanical properties of clay-reinforced polyamide, J. Polym. Sci. B Polym. Phys., 40, 272, 10.1002/polb.10088 Manikandan, 2019, Design and fabrication of MEMS based intracranial pressure sensor for neurons study, Vacuum, 163, 204, 10.1016/j.vacuum.2019.02.018 Muirhead, 2012, Trajectories for frontal external ventricular drain placement: virtual cannulation of adults with acute hydrocephalus, Br. J. Neurosurg., 26, 710, 10.3109/02688697.2012.671973 Wang, 2019, Safety and penetration of light into the brain, 49 Antes, 2016, Telemetric intracranial pressure monitoring with the Raumedic Neurovent P-tel, World neurosurgery, 91, 133, 10.1016/j.wneu.2016.03.096 Kawoos, 2005, A permanently implantable intracranial pressure monitor, 17 Rahman, 2014, Analysis of MEMS diaphragm of piezoresistive intracranial pressure sensor, 681 Williams, 2013, From optogenetic technologies to neuromodulation therapies, Sci. Transl. Med., 5, 177ps6, 10.1126/scitranslmed.3003100 Grossman, 2011, Modeling study of the light stimulation of a neuron cell with channelrhodopsin-2 mutants, IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng., 58, 1742 Berthold, 2008, Channelrhodopsin-1 initiates phototaxis and photophobic responses in Chlamydomonas by immediate light-induced depolarization, Plant Cell, 20, 1665, 10.1105/tpc.108.057919 Zhao, 2008, Improved expression of halorhodopsin for light-induced silencing of neuronal activity, Brain Cell Biol., 36, 141, 10.1007/s11068-008-9034-7 Tsunematsu, 2013, Long-lasting silencing of orexin/hypocretin neurons using archaerhodopsin induces slow-wave sleep in mice, Behav. Brain Res., 255, 64, 10.1016/j.bbr.2013.05.021 Fenno, 2011, The development and application of optogenetics, Annu. Rev. Neurosci., 34, 389, 10.1146/annurev-neuro-061010-113817 Zhang, 2010, Optogenetic interrogation of neural circuits: technology for probing mammalian brain structures, Nat. Protoc., 5, 439, 10.1038/nprot.2009.226 Diester, 2011, An optogenetic toolbox designed for primates, Nat. Neurosci., 14, 387, 10.1038/nn.2749 Baumschlager, 2021, Synthetic biological approaches for optogenetics and tools for transcriptional light-control in bacteria, Advanced Biology, 5, 10.1002/adbi.202000256 Figueroa, 2021, The rise and shine of yeast optogenetics, Yeast, 38, 131, 10.1002/yea.3529 Lindsay, 2011, Optogenetic analysis of synaptic transmission in the central nervous system of the nematode Caenorhabditis elegans, Nat. Commun., 2, 1, 10.1038/ncomms1304 Riemensperger, 2016, Optogenetics in Drosophila neuroscience, 167 Edelstein, 2007, Gene therapy clinical trials worldwide to 2007—an update, J. Gene Med.: A cross-disciplinary journal for research on the science of gene transfer and its clinical applications, 9, 833, 10.1002/jgm.1100 Lim, 2014, Optogenetic mapping after stroke reveals network-wide scaling of functional connections and heterogeneous recovery of the peri-infarct, J. Neurosci., 34, 10.1523/JNEUROSCI.3384-14.2014 Burguière, 2013, Optogenetic stimulation of lateral orbitofrontal-striatal pathway suppresses compulsive behaviors, Science, 340, 1243, 10.1126/science.1232380 Cela, 2019, An optogenetic kindling model of neocortical epilepsy, Sci. Rep., 9, 1, 10.1038/s41598-019-41533-2 Gittis, 2018, Translating insights from optogenetics into therapies for Parkinson's disease, Current opinion in biomedical engineering, 8, 14, 10.1016/j.cobme.2018.08.008 Youngerman, 2016, A decade of emerging indications: deep brain stimulation in the United States, J. Neurosurg., 125, 461, 10.3171/2015.7.JNS142599 Boztas, 2021, Deep brain stimulation for psychiatric disorders: a review, Journal of Bionic Memory, 1, 60, 10.53545/0.20212-372746 Buhlmann, 2011, Modeling of a segmented electrode for desynchronizing deep brain stimulation, Front. Neuroeng., 4, 15, 10.3389/fneng.2011.00015 Girasole, 2018, A subpopulation of striatal neurons mediates levodopa-induced dyskinesia, Neuron, 97, 787, 10.1016/j.neuron.2018.01.017 Gradinaru, 2009, Optical deconstruction of parkinsonian neural circuitry, Science, 324, 354, 10.1126/science.1167093 Sanders, 2016, Optogenetic stimulation of cortico-subthalamic projections is sufficient to ameliorate bradykinesia in 6-ohda lesioned mice, Neurobiol. Dis., 95, 225, 10.1016/j.nbd.2016.07.021 Kravitz, 2010, Regulation of parkinsonian motor behaviours by optogenetic control of basal ganglia circuitry, Nature, 466, 622, 10.1038/nature09159 Mastro, 2017, Cell-specific pallidal intervention induces long-lasting motor recovery in dopamine-depleted mice, Nat. Neurosci., 20, 815, 10.1038/nn.4559 Yttri, 2018, A proposed circuit computation in basal ganglia: history-dependent gain, Mov. Disord., 33, 704, 10.1002/mds.27321 Tye, 2011, Amygdala circuitry mediating reversible and bidirectional control of anxiety, Nature, 471, 358, 10.1038/nature09820 Park, 2017, Optogenetic modulation of urinary bladder contraction for lower urinary tract dysfunction, Sci. Rep., 7, 1 Papagiakoumou, 2013, Optical developments for optogenetics, Biol. Cell., 105, 443, 10.1111/boc.201200087 Goncalves, 2017, Design and manufacturing challenges of optogenetic neural interfaces: a review, J. Neural. Eng., 14, 10.1088/1741-2552/aa7004 Oron, 2012, Two-photon optogenetics, Prog. Brain Res., 196, 119, 10.1016/B978-0-444-59426-6.00007-0 Schmieder, 2018, Optogenetic stimulation of human neural networks using fast ferroelectric spatial light modulator—based holographic illumination, Appl. Sci., 8, 1180, 10.3390/app8071180 Reutsky-Gefen, 2013, Holographic optogenetic stimulation of patterned neuronal activity for vision restoration, Nat. Commun., 4, 1, 10.1038/ncomms2500 Leitgeb, 2018, Multimodal optical medical imaging concepts based on optical coherence tomography, Frontiers in Physics, 6, 114, 10.3389/fphy.2018.00114 Campos, 2015, High brightness LEDs supplied by electronics converters used in tissue healing and cell rejuvenation Sakamoto, 2018, 2354 Kim, 2020, Non-invasive optical control of endogenous Ca2+ channels in awake mice, Nat. Commun., 11, 1 Aravanis, 2007, An optical neural interface: in vivo control of rodent motor cortex with integrated fiberoptic and optogenetic technology, J. Neural. Eng., 4, S143, 10.1088/1741-2560/4/3/S02 Adamantidis, 2007, Neural substrates of awakening probed with optogenetic control of hypocretin neurons, Nature, 450, 420, 10.1038/nature06310 Campagnola, 2008, Fiber-coupled light-emitting diode for localized photostimulation of neurons expressing channelrhodopsin-2, J. Neurosci. Methods, 169, 27, 10.1016/j.jneumeth.2007.11.012 Zhang, 2009, A microelectrode array incorporating an optical waveguide device for stimulation and spatiotemporal electrical recording of neural activity, 2046 Pisanello, 2014, Multipoint-emitting optical fibers for spatially addressable in vivo optogenetics, Neuron, 82, 1245, 10.1016/j.neuron.2014.04.041 Hoffman, 2015, High-density outrode-electrode neural probe using SixNy photonics for in vivo optogenetics, 29.5. 1 Schwaerzle, 2014, Miniaturized tool for optogenetics based on an LED and an optical fiber interfaced by a silicon housing, 5252 Wu, 2013, An implantable neural probe with monolithically integrated dielectric waveguide and recording electrodes for optogenetics applications, J. Neural. Eng., 10, 10.1088/1741-2560/10/5/056012 Rubehn, 2013, A polymer-based neural microimplant for optogenetic applications: design and first in vivo study, Lab Chip, 13, 579, 10.1039/c2lc40874k Guo, 2019, A polyimide-based flexible optoelectrodes for low-noise neural recording, IEEE Electron. Device Lett., 40, 1190, 10.1109/LED.2019.2915323 Kampasi, 2020, Design and microfabrication strategies for thin-film, flexible optical neural implant, 4314 Hassler, 2010, Characterization of parylene C as an encapsulation material for implanted neural prostheses, J. Biomed. Mater. Res. Part B: Applied Biomaterials: An Official Journal of The Society for Biomaterials, 93, 266, 10.1002/jbm.b.31584 Reddy, 2019, High density, double-sided, flexible optoelectronic neural probes with embedded μLEDs, Front. Neurosci., 13, 745, 10.3389/fnins.2019.00745 Hopcroft, 2005, Micromechanical testing of SU-8 cantilevers, Fatig. Fract. Eng. Mater. Struct., 28, 735, 10.1111/j.1460-2695.2005.00873.x Schwaerzle, 2017, Compact silicon-based outrode with integrated laser diode chips, SU-8 waveguides and platinum electrodes for optogenetic applications, J. Micromech. Microeng., 27, 10.1088/1361-6439/aa6ad4 Bernstein, 2011, Optogenetic tools for analyzing the neural circuits of behavior, Trends Cognit. Sci., 15, 592, 10.1016/j.tics.2011.10.003 Bernstein, 2015, Processes for design, construction and utilisation of arrays of light-emitting diodes and light-emitting diode-coupled optical fibres for multi-site brain light delivery, J. Eng. Stark, 2012, Diode probes for spatiotemporal optical control of multiple neurons in freely moving animals, J. Neurophysiol., 108, 349, 10.1152/jn.00153.2012 Stark, 2014, Pyramidal cell-interneuron interactions underlie hippocampal ripple oscillations, Neuron, 83, 467, 10.1016/j.neuron.2014.06.023 Genina, 2019, Optical properties of brain tissues at the different stages of glioma development in rats: pilot study, Biomed. Opt Express, 10, 5182, 10.1364/BOE.10.005182 Korpas, 2014 Royer, 2010, Multi-array silicon probes with integrated optical fibers: light-assisted perturbation and recording of local neural circuits in the behaving animal, Eur. J. Neurosci., 31, 2279, 10.1111/j.1460-9568.2010.07250.x Abaya, 2012, A 3D glass outrode array for optical neural stimulation, Biomed. Opt Express, 3, 3087, 10.1364/BOE.3.003087 Abaya, 2012, Characterization of a 3D outrode array for infrared neural stimulation, Biomed. Opt Express, 3, 2200, 10.1364/BOE.3.002200 Hayashi, 2012, Spatio-temporal control of neural activity in vivo using fluorescence microendoscopy, Eur. J. Neurosci., 36, 2722, 10.1111/j.1460-9568.2012.08191.x Tamura, 2012, A glass-coated tungsten microelectrode enclosing optical fibers for optogenetic exploration in primate deep brain structures, J. Neurosci. Methods, 211, 49, 10.1016/j.jneumeth.2012.08.004 Rubehn, 2011, Polymer-based shaft microelectrodes with optical and fluidic capabilities as a tool for optogenetics, 2969 Im, 2011, Neural probes integrated with optical mixer/splitter waveguides and multiple stimulation sites, 1051 Strömbäck Alvarez, 2014, The influence of neck muscle tonus and posture on brain tissue strain in pedestrian head impacts, Stapp car crash journal, 58, 63 Xiang, 2014, Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle, J. Micromech. Microeng., 24, 10.1088/0960-1317/24/6/065015 Luan, 2017, Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration, Sci. Adv., 3, 10.1126/sciadv.1601966 Muthuswamy, 2012, MEMS neural probes, 1335 Sejnowski, 2014, Putting big data to good use in neuroscience, Nat. Neurosci., 17, 1440, 10.1038/nn.3839