Changes in the posterior corneal surface after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) performed into a pocket (SMI-LIKE) or under a flap (FS-LIKE)

Eye and Vision - Tập 10 Số 1 - Trang 1-10 - 2023
Liu, Shengtao1,2,3,4,5, Yu, Lanhui5, Zhao, Yu1,2,3,4, Zhou, Xingtao1,2,3,4
1Department of Ophthalmology and Optometry, Eye and ENT Hospital of Fudan University, Shanghai, China
2NHC Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Fudan University, Shanghai, China
3Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
4Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
5Affiliated Eye Hospital of Nanchang University, Nanchang, China

Tóm tắt

To compare the changes in posterior corneal surface after small-incision lenticule intrastromal keratoplasty (SMI-LIKE) and femtosecond laser-assisted lenticule intrastromal keratoplasty (FS-LIKE) for hyperopia correction. In this prospective comparative randomized study, 23 eyes with hyperopia were recruited. Eyes were categorized into two groups—SMI-LIKE group (11 eyes) and FS-LIKE group (12 eyes). Lenticules from myopia small incision lenticule extraction were implanted into a pocket (SMI-LIKE group) or at a depth of 100 µm under a flap (FS-LIKE group). Posterior corneal elevations in the center, mid-periphery, and periphery, as well as mean keratometry of the posterior corneal surface (Kmb) were measured using a Pentacam over a three-month follow-up. All surgeries were completed successfully and no complications occurred. At one day postoperatively, there was a slight backward change with SMI-LIKE and a forward change with FS-LIKE in the central region of the posterior corneal elevation. Conversely, the peripheral area showed forward displacement in SMI-LIKE and an apparent backward change in FS-LIKE. The mid-peripheral regions manifested a backward change after the procedure throughout the entire follow-up in both groups. Kmb exhibited flattening at one month postoperatively and subsequently returned to its original level at three months after SMI-LIKE while in FS-LIKE, Kmb steepened after lenticule implantation with a significant change noted at one day postoperatively (P = 0.001). Posterior corneal surface after SMI-LIKE and FS-LIKE exhibited different change patterns in various corneal regions, with the most prominent change occurring at one day postoperatively during the three-month follow-up. Trial registration: Chinese Clinical Trial Registry: ChiCTR-ONC-16008300. Registered on Apr 18th, 2016.  http://www.chictr.org.cn/edit.aspx?pid=14090&htm=4

Tài liệu tham khảo

citation_journal_title=J Cataract Refract Surg; citation_title=Human allograft refractive lenticular implantation for high hyperopiccorrection; citation_author=M Moshirfar, GC Hopping, AN Somani, U Vaidyanathan, H Liu, JR Barnes; citation_volume=46; citation_issue=2; citation_publication_date=2020; citation_pages=305-311; citation_doi=10.1097/j.jcrs.0000000000000011; citation_id=CR1 citation_journal_title=Transl Vis Sci Technol; citation_title=Higher-order-aberrations following hyperopia treatment: small incision lenticule extraction, laser-assisted in situ keratomileusis and lenticule implantation; citation_author=YC Liu, J Wen, EPW Teo, GP Williams, NC Lwin, JS Mehta; citation_volume=7; citation_issue=2; citation_publication_date=2018; citation_pages=15; citation_doi=10.1167/tvst.7.2.15; citation_id=CR2 citation_journal_title=Prog Retin Eye Res; citation_title=Stromal keratophakia: corneal inlay implantation; citation_author=AK Riau, YC Liu, GHF Yam, JS Mehta; citation_volume=75; citation_publication_date=2020; citation_doi=10.1016/j.preteyeres.2019.100780; citation_id=CR3 citation_journal_title=Ophthalmol Ther; citation_title=Comparison of visual outcome after hyperopic LASIK using a wavefront-optimized platform versus other excimer lasers in the past two decades; citation_author=M Moshirfar, A Megerdichian, WB West, CM Miller, RA Sperry, CD Neilsen; citation_volume=10; citation_issue=3; citation_publication_date=2021; citation_pages=547-563; citation_doi=10.1007/s40123-021-00346-1; citation_id=CR4 citation_journal_title=J Refract Surg; citation_title=Femtosecond laser-assisted keyhole endokeratophakia: correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor; citation_author=KR Pradhan, DZ Reinstein, GI Carp, TJ Archer, M Gobbe, R Gurung; citation_volume=29; citation_issue=11; citation_publication_date=2013; citation_pages=777-782; citation_doi=10.3928/1081597X-20131021-07; citation_id=CR5 citation_journal_title=J Refract Surg; citation_title=The safety and predictability of implanting autologous lenticule obtained by SMILE for hyperopia; citation_author=L Sun, P Yao, M Li, Y Shen, J Zhao, X Zhou; citation_volume=31; citation_issue=6; citation_publication_date=2015; citation_pages=374-379; citation_doi=10.3928/1081597X-20150521-03; citation_id=CR6 citation_journal_title=J Refract Surg; citation_title=Comparison of optical zone decentration following FS-LIKE and SMI-LIKE for correcting hyperopia; citation_author=S Liu, X Zhang, L Yu, M Li, X Zhou; citation_volume=38; citation_issue=3; citation_publication_date=2022; citation_pages=184-190; citation_doi=10.3928/1081597X-20211213-03; citation_id=CR7 citation_journal_title=Med Hypothesis Discov Innov Ophthalmol; citation_title=A modified small-incision lenticule intrastromal keratoplasty (sLIKE) for the correction of high hyperopia: a description of a new surgical technique and comparison to lenticule intrastromal keratoplasty (LIKE); citation_author=M Moshirfar, TJ Shah, M Masud, T Fanning, SH Linn, Y Ronquillo; citation_volume=7; citation_issue=2; citation_publication_date=2018; citation_pages=48-56; citation_id=CR8 citation_journal_title=J Refract Surg; citation_title=Biomechanical modeling of femtosecond laser keyhole endokeratophakia surgery; citation_author=HP Studer, KR Pradhan, DZ Reinstein, E Businaro, TJ Archer, M Gobbe; citation_volume=31; citation_issue=7; citation_publication_date=2015; citation_pages=480-486; citation_doi=10.3928/1081597X-20150623-07; citation_id=CR9 citation_journal_title=PLoS ONE; citation_title=Small incision lenticule extraction (SMILE) combined with allogeneic intrastromal lenticule inlay for hyperopia with astigmatism; citation_author=J Zhang, Y Zhou; citation_volume=16; citation_issue=9; citation_publication_date=2021; citation_doi=10.1371/journal.pone.0257667; citation_id=CR10 citation_journal_title=J Refract Surg; citation_title=Correction of moderate to high hyperopia with implantation of an allogeneic refractive lenticule; citation_author=J Wu, L Xiong, Z Wang, DZ Reinstein, RS Vida, TJ Archer; citation_volume=36; citation_issue=11; citation_publication_date=2020; citation_pages=772-779; citation_doi=10.3928/1081597X-20200826-01; citation_id=CR11 citation_journal_title=Sci Rep; citation_title=Biological corneal inlay for presbyopia derived from small incision lenticule extraction (SMILE); citation_author=YC Liu, EPW Teo, HP Ang, XY Seah, NC Lwin, GHF Yam; citation_volume=8; citation_issue=1; citation_publication_date=2018; citation_pages=1831; citation_doi=10.1038/s41598-018-20267-7; citation_id=CR12 citation_journal_title=Ophthalmology; citation_title=Effect of corneal hydration and intraocular pressure on keratometric power after experimental radial keratotomy; citation_author=RK Maloney; citation_volume=97; citation_issue=7; citation_publication_date=1990; citation_pages=927-933; citation_doi=10.1016/S0161-6420(90)32499-5; citation_id=CR13 citation_journal_title=J Refract Surg; citation_title=Depth-dependent cohesive tensile strength in human donor corneas: implications for refractive surgery; citation_author=JB Randleman, DG Dawson, HE Grossniklaus, BE McCarey, HF Edelhauser; citation_volume=24; citation_issue=1; citation_publication_date=2008; citation_pages=S85-S89; citation_id=CR14 citation_journal_title=J Refract Surg; citation_title=Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK, and small incision lenticule extraction; citation_author=DZ Reinstein, TJ Archer, JB Randleman; citation_volume=29; citation_issue=7; citation_publication_date=2013; citation_pages=454-460; citation_doi=10.3928/1081597X-20130617-03; citation_id=CR15 citation_journal_title=Invest Ophthalmol Vis Sci; citation_title=Depth-dependent transverse shear properties of the human corneal stroma; citation_author=SJ Petsche, D Chernyak, J Martiz, ME Levenston, PM Pinsky; citation_volume=53; citation_issue=2; citation_publication_date=2012; citation_pages=873-880; citation_doi=10.1167/iovs.11-8611; citation_id=CR16 citation_journal_title=J Cataract Refract Surg; citation_title=Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis; citation_author=D Wu, Y Wang, L Zhang, S Wei, X Tang; citation_volume=40; citation_issue=60; citation_publication_date=2014; citation_pages=954-962; citation_doi=10.1016/j.jcrs.2013.07.056; citation_id=CR17 citation_journal_title=J Cataract Refract Surg; citation_title=Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: finite-element analysis; citation_author=A Sinha Roy, WJ Dupps, CJ Roberts; citation_volume=40; citation_issue=6; citation_publication_date=2014; citation_pages=971-980; citation_doi=10.1016/j.jcrs.2013.08.065; citation_id=CR18 citation_journal_title=Ophthalmic Surg; citation_title=Refractive keratoplasty with hydrogel implants in primates; citation_author=SB Koenig, T Hamano, T Yamaguchi, T Kimura, MB McDonald, HE Kaufman; citation_volume=15; citation_issue=3; citation_publication_date=1984; citation_pages=225-229; citation_id=CR19 citation_journal_title=J Refract Surg; citation_title=Biological lenticule implantation for correction of hyperopia: an ex vivo study in human corneas; citation_author=IB Damgaard, A Ivarsen, J Hjortdal; citation_volume=34; citation_issue=4; citation_publication_date=2018; citation_pages=245-252; citation_doi=10.3928/1081597X-20180206-01; citation_id=CR20 citation_journal_title=Br J Ophthalmol; citation_title=Small incision lenticule extraction (SMILE) and femtosecond laser LASIK: comparison of corneal wound healing and inflammation; citation_author=Z Dong, X Zhou, J Wu, Z Zhang, T Li, Z Zhou; citation_volume=98; citation_issue=2; citation_publication_date=2014; citation_pages=263-269; citation_doi=10.1136/bjophthalmol-2013-303415; citation_id=CR21 citation_journal_title=Ann Transl Med.; citation_title=Comparison of posterior corneal elevation after SMILE and FS-LASIK in correcting myopia over -90 diopters; citation_author=Y Zhao, Y Qian, X Chen, X Zhou, B Qin, X Zhou; citation_volume=9; citation_issue=5; citation_publication_date=2021; citation_pages=373; citation_doi=10.21037/atm-20-5165; citation_id=CR22 citation_journal_title=Invest Ophthalmol Vis Sci; citation_title=Femtosecond laser-assisted corneal small incision allogenic intrastromal lenticule implantation in monkeys: a pilot study; citation_author=R Liu, J Zhao, Y Xu, M Li, L Niu, H Liu; citation_volume=56; citation_issue=6; citation_publication_date=2015; citation_pages=3715-3720; citation_doi=10.1167/iovs.14-15296; citation_id=CR23 citation_journal_title=Sci Rep; citation_title=Epithelial and stromal remodelling following femtosecond laser-assisted stromal lenticule addition keratoplasty (SLAK) for keratoconus; citation_author=M Nubile, N Salgari, JS Mehta, R Calienno, E Erroi, J Bondì; citation_volume=11; citation_issue=1; citation_publication_date=2021; citation_pages=2293; citation_doi=10.1038/s41598-021-81626-5; citation_id=CR24