Cerium oxide nanofiber–based electrochemical immunosensor for detection of sepsis in biological fluid

Springer Science and Business Media LLC - Tập 25 - Trang 2587-2598 - 2021
Om Krishan Singh1, Sanni Kumar1, Shiv Govind Singh1
1Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Telangana, India

Tóm tắt

Sepsis causes life-threatening complications with the highest burden of death and medical expenses in hospitals worldwide. Despite the progression of targeted therapies for sepsis, the challenge of early diagnosis of sepsis-related biomarkers remains. The analysis of the TNF-α and sTREM-1 in biological fluids provides essential information for effective treatments. In this work, we report developing an electrochemical immunosensor for the rapid detection of TNF-α and sTREM-1 proteins in human plasma samples. First, using the electrospinning process, cerium oxide nanofibers were synthesized. Subsequently, the antibodies corresponding to the targeted proteins are immobilized onto the surface-functionalized working electrodes using NHS/EDC chemistry. The proposed immunosensor’s performance in a biological fluid was assessed using an analytical electrochemistry approach. The limit of detection for the electrochemical immunosensors was 0.51 and 0.41 pg/mL for TNF-α and sTREM-1, respectively, with high selectivity and sensitivity for the use as a point of care device.

Tài liệu tham khảo

Gotts JE, Matthay MA (2016) Sepsis: pathophysiology and clinical management. BMJ 353 Kumar S, Gupta E, Kaushik S et al (2019) Quantification of NETs formation in neutrophil and its correlation with the severity of sepsis and organ dysfunction. Clin Chim Acta 495:606–610. https://doi.org/10.1016/j.cca.2019.06.008 Barie PS (2012) World Sepsis Day: September 13, 2012. Surg Infect (Larchmt) 13:185–186. https://doi.org/10.1089/sur.2012.9905 Ziegler I, Fagerström A, Strålin K, Mölling P (2016) Evaluation of a commercial multiplex PCR assay for detection of pathogen DNA in blood from patients with suspected sepsis. PLoS One 11:e0167883. https://doi.org/10.1371/journal.pone.0167883 Sener G, Ozgur E, Rad AY et al (2013) Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor. Analyst 138:6422–6428. https://doi.org/10.1039/c3an00958k Kumar S, Gupta E, Kaushik S et al (2018) Evaluation of oxidative stress and antioxidant status: correlation with the severity of sepsis. Scand J Immunol 87:e12653. https://doi.org/10.1111/sji.12653 Kumar S, Gupta E, Srivastava VK et al (2019) Nitrosative stress and cytokines are linked with the severity of sepsis and organ dysfunction. Br J Biomed Sci 76:29–34. https://doi.org/10.1080/09674845.2018.1543160 Lequin RM (2005) Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). Clin Chem 51:2415–2418. https://doi.org/10.1373/clinchem.2005.051532 Mistry KK, Layek K, Mahapatra A et al (2014) A review on amperometric-type immunosensors based on screen-printed electrodes. Analyst 139:2289–2311. https://doi.org/10.1039/C3AN02050A Ferrari AG-M, Foster CW, Kelly PJ et al (2018) Determination of the electrochemical area of screen-printed electrochemical sensing platforms. Biosens 8:53. https://doi.org/10.3390/BIOS8020053 Gao J, Jeffries L, Mach KE et al (2017) A multiplex electrochemical biosensor for bloodstream infection diagnosis. SLAS Technol 22:466. https://doi.org/10.1177/2211068216651232 Arya SK, Estrela P (2017) Electrochemical immunosensor for tumor necrosis factor-alpha detection in undiluted serum. Methods 116:125–131. https://doi.org/10.1016/J.YMETH.2016.12.001 Eletxigerra U, Martinez-Perdiguero J, Merino S et al (2014) Amperometric magnetoimmunoassay for the direct detection of tumor necrosis factor alpha biomarker in human serum. Anal Chim Acta 838:37–44. https://doi.org/10.1016/J.ACA.2014.05.047 Liu Y, Kwa T, Revzin A (2012) Simultaneous detection of cell-secreted TNF-α and IFN-γ using micropatterned aptamer-modified electrodes. Biomaterials 33:7347–7355. https://doi.org/10.1016/J.BIOMATERIALS.2012.06.089 Min Lim J, Yi Ryu M, Hong Kim J et al (2017) An electrochemical biosensor for detection of the sepsis-related biomarker procalcitonin. RSC Adv 7:36562–36565. https://doi.org/10.1039/C7RA06553A Kumar S, Bukkitgar SD, Singh S et al (2019) Electrochemical sensors and biosensors based on graphene functionalized with metal oxide nanostructures for healthcare applications. ChemistrySelect 4:5322–5337. https://doi.org/10.1002/slct.201803871 Kumar S, Tripathy S, Jyoti A, Singh SG (2019) Recent advances in biosensors for diagnosis and detection of sepsis: A comprehensive review. Biosens Bioelectron 124–125:205–215 Jean-Baptiste E (2007) Cellular mechanisms in sepsis. J Intensive Care Med 22:63–72. https://doi.org/10.1177/0885066606297123 Bouchon A, Facchetti F, Weigand MA, Colonna M (2001) TREM-1 amplifies inflammation and is a crucial mediator of septic shock. Nature 410:1103–1107. https://doi.org/10.1038/35074114 Bleharski JR, Kiessler V, Buonsanti C et al (2003) A role for triggering receptor expressed on myeloid cells-1 in host defense during the early-induced and adaptive phases of the immune response. J Immunol 170:3812–3818. https://doi.org/10.4049/jimmunol.170.7.3812 Gibot S, Kolopp-Sarda MN, Béné MC et al (2004) Plasma level of a triggering receptor expressed on myeloid cells-1: its diagnostic accuracy in patients with suspected sepsis. Ann Intern Med 141:9–15. https://doi.org/10.7326/0003-4819-141-1-200407060-00009 Ríos-Toro J-J, Márquez-Coello M, García-Álvarez J-M et al (2017) Soluble membrane receptors, interleukin 6, procalcitonin and C reactive protein as prognostic markers in patients with severe sepsis and septic shock. PLoS One 12:e0175254. https://doi.org/10.1371/journal.pone.0175254 Supraja P, Tripathy S, Krishna Vanjari SR et al (2019) Electrospun tin (IV) oxide nanofiber based electrochemical sensor for ultra-sensitive and selective detection of atrazine in water at trace levels. Biosens Bioelectron 141:111441. https://doi.org/10.1016/J.BIOS.2019.111441 Brince Paul K, Kumar S, Tripathy S et al (2016) A highly sensitive self assembled monolayer modified copper doped zinc oxide nanofiber interface for detection of Plasmodium falciparum histidine-rich protein-2: Targeted towards rapid, early diagnosis of malaria. Biosens Bioelectron 80:39–46. https://doi.org/10.1016/J.BIOS.2016.01.036 Tripathy S, Krishna Vanjari SR, Singh V et al (2017) Electrospun manganese (III) oxide nanofiber based electrochemical DNA-nanobiosensor for zeptomolar detection of dengue consensus primer. Biosens Bioelectron 90:378–387. https://doi.org/10.1016/J.BIOS.2016.12.008 Tripathy S, Gangwar R, Supraja P et al (2018) Graphene doped Mn 2 O 3 nanofibers as a facile electroanalytical DNA point mutation detection platform for early diagnosis of breast/ovarian cancer. Electroanalysis 30:2110–2120. https://doi.org/10.1002/elan.201800220 Kumar S, Vasylieva N, Singh V et al (2020) A Facile, Sensitive and rapid sensing platform based on CoZnO for detection of Fipronil; an environmental toxin. Electroanalysis 202000051. https://doi.org/10.1002/elan.202000051 Yang X, Ouyang Y, Wu F et al (2016) In situ & controlled preparation of platinum nanoparticles dopping into graphene sheets@cerium oxide nanocomposites sensitized screen printed electrode for nonenzymatic electrochemical sensing of hydrogen peroxide. J Electroanal Chem 777:85–91. https://doi.org/10.1016/j.jelechem.2016.08.008 Ding H, Yang J, Ma S et al (2018) Large dimensional CeO 2 nanoflakes by microwave-assisted synthesis: lamellar nano-channels and surface oxygen vacancies promote catalytic activity. ChemCatChem 10:4100–4108. https://doi.org/10.1002/cctc.201800784 Kumar S, Tripathy S, Krishan Singh O, Govind Singh S (2020) Cerium oxide nanofiber based electroanalytical sensor for TNF-α detection: improved interfacial stability with Nafion. Bioelectrochemistry 107725. https://doi.org/10.1016/j.bioelechem.2020.107725 Tripathy S, Gangwar R, Supraja P et al (2018) Graphene doped Mn 2 O 3 nanofibers as a facile electroanalytical DNA point mutation detection platform for early diagnosis of breast/ovarian cancer. 1–12. https://doi.org/10.1002/elan.201800220 Sims CM, Maier RA, Johnston-Peck AC et al (2019) Approaches for the quantitative analysis of oxidation state in cerium oxide nanomaterials. Nanotechnology 30:85703. https://doi.org/10.1088/1361-6528/aae364 Matolín V, Matolínov I, Sedlek L et al (2009) A resonant photoemission applied to cerium oxide based nanocrystals. Nanotechnology 20:215706. https://doi.org/10.1088/0957-4484/20/21/215706 Ali MM, Mahdi HS, Parveen A, Azam A (2018) Optical properties of cerium oxide (CeO2) nanoparticles synthesized by hydroxide mediated method. In: AIP Conference Proceedings. American Institute of Physics Inc. Killedar L, Ilager D, Shetti NP et al (2021) Synthesis of ruthenium doped titanium dioxide nanoparticles for the electrochemical detection of diclofenac sodium. J Mol Liq 116891. https://doi.org/10.1016/J.MOLLIQ.2021.116891 Mazloum-Ardakani M, Hosseinzadeh L, Khoshroo A (2015) Label-free electrochemical immunosensor for detection of tumor necrosis factor α based on fullerene-functionalized carbon nanotubes/ionic liquid. J Electroanal Chem 757:58–64. https://doi.org/10.1016/j.jelechem.2015.09.006 Yagati AK, Lee MH, Min J (2018) Electrochemical immunosensor for highly sensitive and quantitative detection of tumor necrosis factor-α in human serum. Bioelectrochemistry 122:93–102. https://doi.org/10.1016/j.bioelechem.2018.03.007 Yagati AK, Lee GY, Ha S et al (2016) Impedimetric tumor necrosis factor-α sensor based on a reduced graphene oxide nanoparticle-modified electrode array. J Nanosci Nanotechnol 16:11921–11927. https://doi.org/10.1166/jnn.2016.13618 Liu A, Shan H, Ma M et al (2017) An ultrasensitive photoelectrochemical immunosensor by integration of nanobody, TiO2 nanorod arrays and ZnS nanoparticles for the detection of tumor necrosis factor-α. J Electroanal Chem 803:1–10. https://doi.org/10.1016/j.jelechem.2017.09.008 Yin Z, Liu Y, Jiang LP, Zhu JJ (2011) Electrochemical immunosensor of tumor necrosis factor α based on alkaline phosphatase functionalized nanospheres. Biosens Bioelectron 26:1890–1894. https://doi.org/10.1016/j.bios.2010.03.025 Weng S, Chen M, Zhao C et al (2013) Label-free electrochemical immunosensor based on K3[Fe(CN) 6] as signal for facile and sensitive determination of tumor necrosis factor-alpha. Sensors Actuators, B Chem 184:1–7. https://doi.org/10.1016/j.snb.2013.03.141 Mazloum-Ardakani M, Hosseinzadeh L, Taleat Z (2014) Two kinds of electrochemical immunoassays for the tumor necrosis factor α in human serum using screen-printed graphite electrodes modified with poly(anthranilic acid). Microchim Acta 181:917–924. https://doi.org/10.1007/s00604-014-1186-9 Bellagambi FG, Baraket A, Longo A et al (2017) Electrochemical biosensor platform for TNF-α cytokines detection in both artificial and human saliva: heart failure. Sensors Actuators, B Chem 251:1026–1033. https://doi.org/10.1016/j.snb.2017.05.169 Barhoumi L, Baraket A, Bellagambi FG et al (2018) A novel chronoamperometric immunosensor for rapid detection of TNF-Α in human saliva. Sensors Actuators, B Chem 266:477–484. https://doi.org/10.1016/J.SNB.2018.03.135 Arya SK, Estrela P (2020) Electrochemical ELISA protein biosensing in undiluted serum using a polypyrrole-based platform. Sensors 20:2857. https://doi.org/10.3390/S20102857 Bahk Y-KH-HD-SS-CJ-S (2011) A new concept for efficient sensitivity amplification of a QCM based immunosensor for TNF-α by using modified magnetic particles under applied magnetic field. Bull Korean Chem Soc 32:4215–4220. https://doi.org/10.5012/BKCS.2011.32.12.4215 Liu Y, Liu Y, Matharu Z et al (2015) Detecting multiple cell-secreted cytokines from the same aptamer-functionalized electrode. Biosens Bioelectron 64:43–50. https://doi.org/10.1016/J.BIOS.2014.08.034