Cardiac Output Monitoring: Comparison of a New Arterial Pressure Waveform Analysis to the Bolus Thermodilution Technique in Patients Undergoing Off-Pump Coronary Artery Bypass Surgery

Journal of Cardiothoracic and Vascular Anesthesia - Tập 22 - Trang 394-399 - 2008
Yatin Mehta1, Rajesh Kumar Chand1, Ravindra Sawhney1, Milind Bhise1, Ajmer Singh1, Naresh Trehan1
1Department of Anaesthesiology and Critical Care, Escorts Heart Institute and Research Centre, New Delhi, India.

Tài liệu tham khảo

Wallace, 1993, Effect of iced and room temperature injectate on cardiac output measurements in critically ill patients with low and high cardiac output, Heart Lung, 22, 55 Bazaral, 1992, Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass, Anesthesiology, 73, 21 Latson, 1993, Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass, Anesthesiology, 79, 1233, 10.1097/00000542-199312000-00014 Connors, 1996, The effectiveness of right heart catheterization in initial care of the critically ill patients, JAMA, 276, 889, 10.1001/jama.1996.03540110043030 2006, Pulmonary artery versus central venous catheter to guide treatment of acute lung injury, N Engl J Med, 354, 2213, 10.1056/NEJMoa061895 Chand, 2006, Cardiac output estimation after off-pump coronary artery bypass with a new Doppler device, J Cardiothorac Vasc Anesth, 20, 315, 10.1053/j.jvca.2005.05.024 Sageman, 2002, Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery, J Cardiothoracic Vasc Anesth, 16, 8, 10.1053/jcan.2002.29635 Jaeggi, 2003, Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device, J Cardiothoracic Vasc Anesth, 17, 217, 10.1053/jcan.2003.50 Robinson, 2003, Continuous measurement of cardiac output by inert gas throughflow: Comparison with thermodilution, J Cardiothorac Vasc Anesth, 17, 204, 10.1053/jcan.2003.48 Sujatha, 2006, Comparison of cardiac output in OPCAB: Bolus thermodilution technique vs pulse contour analysis, Ann Card Anaesth, 9, 44, 10.4103/0971-9784.37896 Linton, 1997, Lithium dilution cardiac output measurement: A comparison with thermodilution, Crit Care Med, 25, 1796, 10.1097/00003246-199711000-00015 Fahrenberg, 1997, Non invasive estimation of ventricular ejection time and stroke volume: Comparison of impedance cardiography and the Portapres 2, J Med Eng Technol, 21, 15, 10.3109/03091909709030298 Erlanger, 1904, An experimental study of blood pressure and of pulse-pressure in man, Johns Hopkins Hosp Rep, 12, 145 Wesseling, 1993, Computation of aortic flow from pressure in humans using a nonlinear, three-element model, J Appl Physiol, 74, 2566, 10.1152/jappl.1993.74.5.2566 Rauch, 2002, Pulse contour analysis versus thermodilution in cardiac surgery patients, Acta Anaesthesiol Scand, 46, 424, 10.1034/j.1399-6576.2002.460416.x Jansen, 2001, A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients, Br J Anaesth, 87, 212, 10.1093/bja/87.2.212 Pratt, 2007, Calculating arterial pressure-based cardiac output using a novel measurement and analysis method, Biomed Instrum Technol, 41, 403, 10.2345/0899-8205(2007)41[403:CAPCOU]2.0.CO;2 Manecke, 2005, Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave, Expert Rev Med Devices, 2, 523, 10.1586/17434440.2.5.523 Bland, 1999, Measuring agreement in method comparison studies, Stat Methods Med Res, 8, 135, 10.1177/096228029900800204 Critchley, 1999, A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques, J Clin Monit, 15, 85, 10.1023/A:1009982611386 Manecke, 2007, Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration, J Cardiothorac Vasc Anesth, 21, 3, 10.1053/j.jvca.2006.08.004 Mayer, 2007, Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: A comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery, Br J Anaesth, 98, 176, 10.1093/bja/ael341 Opdam, 2006, A pilot assessment of the FloTrac cardiac output monitoring system, Intensive Care Med, 33, 344, 10.1007/s00134-006-0410-4 Sander, 2006, Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements, Crit Care, 10, R164, 10.1186/cc5103 Button, 2007, Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery, Br J Anaesth, 99, 329, 10.1093/bja/aem188 Pinsky, 2003, Probing the limits of arterial pulse contour analysis to predict preload responsiveness, Anesth Analg, 96, 1245, 10.1213/01.ANE.0000055821.40075.38