Cardiac Output Measurement by Partial Carbon Dioxide Rebreathing, 2-Dimensional Echocardiography, and Lithium-Dilution Method in Anesthetized Neonatal Foals
Tóm tắt
Từ khóa
Tài liệu tham khảo
Tibby, 2003, Monitoring cardiac function in intensive care, Arch Dis Child, 88, 46, 10.1136/adc.88.1.46
Corley, 2002, Monitoring and treating haemodynamic disturbances in critically ill neonatal foals. Part 1: Haemodynamic monitoring, Equine Vet Educ, 4, 345
Magdesian, 2004, Monitoring the critically ill equine patient, Vet Clin North Am Equine Pract, 20, 11, 10.1016/j.cveq.2003.12.001
Marino, 1997, The ICU Book, 143
Corley, 2004, Inotropes and vasopressors in adults and foals, Vet Clin North Am Equine Pract, 20, 77, 10.1016/j.cveq.2003.12.003
Mimoz, 1994, Pulmonary artery catheterization in critically ill patients: A prospective analysis of outcome changes associated with catheter-prompted changes in therapy, Crit Care Med, 22, 573, 10.1097/00003246-199404000-00011
Steingrub, 1991, Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU, Chest, 99, 1451, 10.1378/chest.99.6.1451
Tibby, 2002, Measurement of cardiac output and tissue perfusion, Curr Opin Pediatr, 14, 303, 10.1097/00008480-200206000-00004
Thomas, 1987, Systemic and pulmonary haemodynamics in normal neonatal foals, J Reprod Fertil, 35, 623
Lavoie, 1990, Haemodynamic, pathological, haematological and behavioural changes during endotoxin infusion in equine neonates, Equine Vet J, 22, 23, 10.1111/j.2042-3306.1990.tb04198.x
Corley, 2002, Comparison of lithium dilution and thermodilution cardiac output measurements in anaesthetised neonatal foals, Equine Vet J, 34, 598, 10.2746/042516402776180287
Connors, 1996, The effectiveness of right heart catheterization in the initial care of critically ill patients, JAMA, 276, 889, 10.1001/jama.1996.03540110043030
Sandham, 2003, A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients, N Engl J Med, 348, 5, 10.1056/NEJMoa021108
14. Schlipf JW , Dunlop CI , Getzy DM , et al. Lesions associated with cardiac catheterization and thermodilution cardiac output determination in horses. Proceedings of the 5th International Congress of Veterinary Anesthesia August 21-25, 1994:71.
Linton, 1993, A new method of measuring cardiac output in man using lithium dilution, Br J Anaesth, 71, 262, 10.1093/bja/71.2.262
Linton, 2000, Cardiac output measured by lithium dilution and transpulmonary thermodilution in patients in a paediatric intensive care unit, Intensive Care Med, 26, 1507, 10.1007/s001340051347
Linton, 2000, Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses, Am J Vet Res, 61, 731, 10.2460/ajvr.2000.61.731
Mason, 2001, Assessment of lithium dilution cardiac output as a technique for measurement of cardiac output in dogs, Am J Vet Res, 62, 1255, 10.2460/ajvr.2001.62.1255
Corley, 2003, Cardiac output technologies with special reference to the horse, J Vet Intern Med, 17, 262, 10.1111/j.1939-1676.2003.tb02447.x
Chaney, 2002, Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology, Crit Care Med, 30, 2338, 10.1097/00003246-200210000-00025
Jaffe, 1999, Partial CO2 rebreathing cardiac output-Operating principles of the NICO system, J Clin Monit Comput, 15, 387, 10.1023/A:1009981313076
Haryadi, 2000, Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output, J Clin Monit Comput, 16, 361, 10.1023/A:1011403717822
Odenstedt, 2002, Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients, Acta Anaesthesiol Scand, 46, 152, 10.1034/j.1399-6576.2002.t01-1-460205.x
Gunkel, 2004, Comparison of noninvasive cardiac output measurement by partial carbon dioxide rebreathing with the lithium dilution method in anesthetized dogs, J Vet Emerg Crit Care, 14, 1, 10.1111/j.1534-6935.2004.04017.x
Blissitt, 1997, Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution, Equine Vet J, 29, 18, 10.1111/j.2042-3306.1997.tb01631.x
Brown, 2002, Use of echocardiography for hemodynamic monitoring, Crit Care Med, 30, 1361, 10.1097/00003246-200206000-00039
Allen, 1983, A preliminary investigation on the use of thermodilution and echocardiography as an assessment of cardiac function in the cat, Can J Comp Med, 47, 112
Uehara, 1995, Determination of cardiac output by echocardiography, J Vet Med Sci, 57, 401, 10.1292/jvms.57.401
Reef, 1998, Equine Diagnostic Ultrasound, 215
Folland, 1979, Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques, Circulation, 60, 760, 10.1161/01.CIR.60.4.760
Schiller, 1989, Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms, J Am Soc Echocardiogr, 2, 358, 10.1016/S0894-7317(89)80014-8
Pombo, 1971, Left ventricular volumes and ejection fraction by echocardiography, Circulation, 43, 480, 10.1161/01.CIR.43.4.480
Bland, 1999, Measuring agreement in method comparison studies, Stat Methods Med Res, 8, 135, 10.1177/096228029900800204
Critchley, 1999, A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques, J Clin Monit Comput, 15, 85, 10.1023/A:1009982611386
Dewitte, 2002, Application of the Bland-Altman plot for interpretation of method-comparison studies: A critical investigation of its practice, Clin Chem, 48, 799, 10.1093/clinchem/48.5.799
Shoemaker, 1994, Multicenter trial of a new thoracic electrical bioimpedance device for cardiac output estimation, Crit Care Med, 22, 1907, 10.1097/00003246-199412000-00004
Mackenzie, 1986, Method of assessing the reproducibility of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers, Br Heart J, 55, 14, 10.1136/hrt.55.1.14
Stetz, 1982, Reliability of the thermodilution method in the determination of cardiac output in clinical practice, Am Rev Respir Dis, 126, 1001
Tulzo, 1996, Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method, J Clin Monit, 12, 379, 10.1007/BF02077635
Rossdale, 1967, Clinical studies on the newborn thoroughbred foal. II. Heart rate, auscultation and electrocardiogram, Br Vet J, 123, 521, 10.1016/S0007-1935(17)39652-5
Mason, 2002, Effect of background serum lithium concentrations on the accuracy of lithium dilution cardiac output determination in dogs, Am J Vet Res, 63, 1048, 10.2460/ajvr.2002.63.1048
Thomas, 1987, Systemic and pulmonary haemodynamics in normal neonatal foals, J Reprod Fertil, 35, 623
Bland, 1986, Statistical methods for assessing agreement between two methods of clinical measurement, Lancet, 1, 307, 10.1016/S0140-6736(86)90837-8
Kuroda, 1994, Left ventricular volume and mass: Comparative study of two-dimensional echocardiography and ultrafast computed tomography, Echocardiography, 11, 1, 10.1111/j.1540-8175.1994.tb01040.x
Teichholz, 1976, Problems in echo-cardiographic volume determinations: Echocardiographic-angiographic correlations in the presence of absence of a synergy, Am J Cardiol, 37, 7, 10.1016/0002-9149(76)90491-4
Mercier, 1982, Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children, Circulation, 65, 962, 10.1161/01.CIR.65.5.962
Gueret, 1981, Two-dimensional echocardiographic assessment of left ventricular stroke volume: Experimental correlation with thermodilution and cineangiography in normal and ischemic states, Cathet Cardiovasc Diagn, 7, 247, 10.1002/ccd.1810070304
Wyatt, 1980, Crosssectional echocardiography. II. Analysis of mathematic models for quantifying volume of the formalin-fixed left ventricle, Circulation, 61, 1119, 10.1161/01.CIR.61.6.1119
Mohan, 1992, Crosssectional echocardiographic diagnosis of a congenital aneurysm of the muscular interventricular septum, Int J Cardiol, 35, 415, 10.1016/0167-5273(92)90243-V
Fast, 1990, Limits of reproducibility of cross-sectional echocardiographic measurement of left ventricular ejection fraction, Int J Cardiol, 28, 67, 10.1016/0167-5273(90)90010-3
Heerden, 2000, Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit, Anaesth Intensive Care, 28, 427, 10.1177/0310057X0002800412
Maxwell, 2001, Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma, J Trauma, 51, 849, 10.1097/00005373-200111000-00005
Nilsson, 2001, Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output, Acta Anaesthesiol Scand, 45, 680, 10.1034/j.1399-6576.2001.045006680.x