Cardiac Magnetic Resonance Imaging for the Diagnosis of Infective Endocarditis in the COVID-19 Era

Current Problems in Cardiology - Tập 48 - Trang 101396 - 2023
Sapan Bhuta1, Neha J. Patel2, Jacob A. Ciricillo2, Michael N. Haddad2, Waleed Khokher2, Mohammed Mhanna3, Mitra Patel2, Cameron Burmeister1, Hazem Malas2, Joel A. Kammeyer2
1Department of Internal Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA
2Department of Medicine, College of Medicine and Life Sciences, University of Toledo, Toledo, OH, USA
3Division of Cardiology, Department of Medicine, University of Iowa, Iowa City, IA, USA

Tài liệu tham khảo

Hubers, 2020, Infective endocarditis: a contemporary review, Mayo Clin Proc, 95, 982, 10.1016/j.mayocp.2019.12.008 Baddour, 2015, Infective endocarditis in adults: diagnosis, antimicrobial therapy, and management of complications: a scientific statement for healthcare professionals from the American Heart Association, Circulation, 132, 1435, 10.1161/CIR.0000000000000296 Otto, 2021, 2020 ACC/AHA guideline for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines, Circulation, 143, e72 Bashore, 2006, Update on infective endocarditis, Curr Probl Cardiol, 31, 274, 10.1016/j.cpcardiol.2005.12.001 Durack, 1994, New criteria for diagnosis of infective endocarditis: utilization of specific echocardiographic findings. Duke Endocarditis Service, Am J Med, 96, 200, 10.1016/0002-9343(94)90143-0 Li, 2000, Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis, Clin Infect Dis, 30, 633, 10.1086/313753 Habib, 2015, Eur Heart J, 36, 3075, 10.1093/eurheartj/ehv319 Horgan, 2020, Cardiovascular imaging in infective endocarditis: a multimodality approach, Circ Cardiovasc Imaging, 13, 10.1161/CIRCIMAGING.120.008956 Bai, 2017, Diagnostic accuracy of transthoracic echocardiography for infective endocarditis findings using transesophageal echocardiography as the reference standard: a meta-analysis, J Am Soc Echocardiogr, 30, 639, 10.1016/j.echo.2017.03.007 Erba, 2019, Multimodality imaging in infective endocarditis: an imaging team within the endocarditis team, Circulation, 140, 1753, 10.1161/CIRCULATIONAHA.119.040228 Eder, 2021, Multimodality imaging in the diagnosis of prosthetic valve endocarditis: a brief review, Front Cardiovasc Med, 8, 10.3389/fcvm.2021.750573 Leiner, 2020, SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance, J Cardiovasc Magn Reson, 22, 76, 10.1186/s12968-020-00682-4 Hundley, 2010, ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents, J Am Coll Cardiol, 55, 2614, 10.1016/j.jacc.2009.11.011 Vahanian, 2022, 2021 ESC/EACTS Guidelines for the management of valvular heart disease, Eur Heart J, 43, 561, 10.1093/eurheartj/ehab395 Kirkpatrick, 2020, ASE statement on protection of patients and echocardiography service providers during the 2019 novel coronavirus outbreak: Endorsed by the American College of Cardiology, J Am Soc Echocardiogr, 33, 648, 10.1016/j.echo.2020.04.001 Skulstad, 2020, COVID-19 pandemic and cardiac imaging: EACVI recommendations on precautions, indications, prioritization, and protection for patients and healthcare personnel, Eur Heart J Cardiovasc Imaging, 21, 592, 10.1093/ehjci/jeaa072 Dursun, 2015, The utility of cardiac MRI in diagnosis of infective endocarditis: preliminary results, Diagn Interv Radiol, 21, 28, 10.5152/dir.2014.14239 Zatorska, 2015, The usefulness of magnetic resonance imaging in the diagnosis of infectious endocarditis, J Heart Valve Dis, 24, 767 Tseng, 2016, Introduction to cardiovascular magnetic resonance: technical principles and clinical applications, Acta Cardiol Sin, 32, 129 Hudsmith, 2006, Determination of cardiac volumes and mass with FLASH and SSFP cine sequences at 1.5 vs. 3 Tesla: a validation study, J Magn Reson Imaging, 24, 312, 10.1002/jmri.20638 Suttie, 2012, 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T, NMR Biomed, 25, 27, 10.1002/nbm.1708 Stäb, 2019, Cardiac magnetic resonance imaging at 7 Tesla, J Vis Exp, 10.3791/55853 Schneider, 2011, Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla, Magn Reson Med, 65, 60, 10.1002/mrm.22605 Demirkiran, 2022, Clinical intra-cardiac 4D flow CMR: acquisition, analysis, and clinical applications, Eur Heart J Cardiovasc Imaging, 23, 154, 10.1093/ehjci/jeab112 Urmeneta, 2019, 4D Flow cardiovascular magnetic resonance versus 3D transesophageal echocardiography in a mitral paravalvular leak, JACC Case Rep, 1, 438, 10.1016/j.jaccas.2019.08.004 Cao, 2022, Free-breathing, non-ECG, simultaneous myocardial T(1), T(2), T(2) *, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking, Magn Reson Med, 26, 1748, 10.1002/mrm.29351 Roifman, 2019, Evaluating a novel free-breathing accelerated cardiac MRI cine sequence in patients with cardiomyopathy, Magn Reson Imaging, 61, 260, 10.1016/j.mri.2019.06.008 Ghodrati, 2021, Temporally aware volumetric generative adversarial network-based MR image reconstruction with simultaneous respiratory motion compensation: Initial feasibility in 3D dynamic cine cardiac MRI, Magn Reson Med, 86, 2666, 10.1002/mrm.28912 Dahiya, 2021, Impact of magnetic resonance imaging on functional integrity of non-conditional cardiovascular implantable electronic devices, Pacing Clin Electrophysiol, 44, 1312, 10.1111/pace.14298 Minaskeian, 2022, Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch, J Appl Clin Med Phys, 23, e13520, 10.1002/acm2.13520 Langman, 2011, Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI, J Magn Reson Imaging, 33, 426, 10.1002/jmri.22463 Mattei, 2015, Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant, Magn Reson Med, 73, 390, 10.1002/mrm.25106 Padmanabhan, 2018, Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads, Heart Rhythm, 15, 228, 10.1016/j.hrthm.2017.10.022 Schaller, 2021, Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads, JAMA Cardiol, 6, 549, 10.1001/jamacardio.2020.7572 Schwartz, 2021, Evaluation of image quality of wideband single-shot late gadolinium-enhancement MRI in patients with a cardiac implantable electronic device, J Cardiovasc Electrophysiol, 32, 138, 10.1111/jce.14798 Singh, 2021, Impact of wideband late gadolinium enhancement cardiac magnetic resonance imaging on device-related artifacts in different implantable cardioverter-defibrillator types, J Magn Reson Imaging, 54, 1257, 10.1002/jmri.27608 Do, 2018, Cardiac magnetic resonance imaging using wideband sequences in patients with nonconditional cardiac implanted electronic devices, Heart Rhythm, 15, 218, 10.1016/j.hrthm.2017.10.003