Cadaveric Models for Renal Transplant Surgery Education: a Comprehensive Review

Current Urology Reports - Tập 21 - Trang 1-7 - 2020
Lidia Coloma1, Ramiro Cabello1, Carmen González1, Cristina Quicios1, Gonzalo Bueno1, Juan Vicente García1, Ana Begoña Arribas2, Francisco Clascá3
1Urology Department, Hospital Universitario Fundación Jiménez Díaz/Universidad Autónoma de Madrid, Madrid, Spain
2Vascular Surgery Department, Hospital Universitario Fundación Jiménez Díaz/Universidad Autónoma de Madrid, Madrid, Spain
3Anatomy, Histology and Neuroscience Department, School of Medicine, Universidad Autónoma de Madrid, Madrid, Spain

Tóm tắt

To evaluate the utility of cadaveric models for kidney transplant (KT) surgery training. Medline® and PubMed® databases were searched for English and Spanish language articles published describing different learning models used in KT formation. We evaluated the use of cadavers preserved by Thiel’s embalming method (TEM) as KT simulation models. Students were divided in groups of 4 people: four trainees mentored by an expert in KT surgery. Among the trainees were surgical residents and low-experience surgeons. A total of 39 TEM preserved bodies were used, of which 75 viable renal grafts were obtained. In each cadaver, two complete transplantation processes were performed, each consisting of en bloc nephrectomy with the trunk of aorta and inferior vena cava, bench surgery and perfusion with saline of the organ, and KT surgery. As with any surgical procedure, learning KT surgery is a stepwise process that requires years of dedication. The models available for the surgical simulation of KT surgery allow to practice and achieve dexterity in performing the procedure in a safe and reproducible way. Training on TEM-preserved corpses offers a highly realistic model for the surgical simulation of KT surgery.

Tài liệu tham khảo

Tonelli M, Wiebe N, Knoll G, Bello A, Browne S, Jadhav D, et al. Systematic review: kidney transplantation compared with dialysis in clinically relevant outcomes. Am J Transplant. 2011;11(10):2093–109. Newsletter transplant. International figures on donation and transplantation 2018. 2018; 99. •• Cabello R, González C, Quicios C, Bueno G, García JV, Arribas AB, et al. An experimental model for training in renal transplantation surgery with human cadavers preserved using W. Thiel’s Embalming Technique. J Surg Educ. 2015;72(2):192–7. Explains more details about the KT simulation model in cadavers embalmed with TEM. Golriz M, Hafezi M, Garoussi C, Fard N, Arvin J, Fonouni H, et al. Do we need animal hands-on courses for transplantation surgery? Clin Transpl. 2013;27:6–15. Kapadia MR, DaRosa DA, MacRae HM, Dunnington GL. Current assessment and future directions of surgical skills laboratories. J Surg Educ. 2007;64(5):260–5. Hamdorf JM, Hall JC. Acquiring surgical skills. Br J Surg. 2000;87(1):28–37. Goff BA. Changing the paradigm in surgical education. Obstet Gynecol. 2008;112(2 Pt 1):328–32. Burnand H, Mutimer J. Surgical training in your hands: organising a skills course. Clin Teach. 2012;9(6):408–12. Golriz M, Fonouni H, Nickkholgh A, Hafezi M, Garoussi C, Mehrabi A. Pig kidney transplantation: an up-to-date guideline. Eur Surg Res Eur Chir Forsch Rech Chir Eur. 2012;49(3–4):121–9. Holland JP, Waugh L, Horgan A, Paleri V, Deehan DJ. Cadaveric hands-on training for surgical specialties: is this back to the future for surgical skills development? J Surg Educ. 2011;68(2):110–6. • Aydin A, Shafi AMA, Shamim Khan M, Dasgupta P, Ahmed K. Current status of simulation and training models in urological surgery: a systematic review. J Urol. 2016;196(2):312–20. Reviews currently available training models for urological surgery, their status of validation and the evidence behind each model. Breda A, Budde K, Figueiredo A, Lledo E. EAU-Guidelines-on-Renal-Transplantation-2019.pdf [Internet]. 2019. Available from: www.uroweb.org. Burgos FJ, Alcaraz A, Castillón I, González Martín M, Lledó E, Matesanz R, et al. Present and future of kidney transplantation. Actas Urol Esp. 2002;26(10):731–58. Cabello-Benavente R, González-Enguita C. Residency in urology and training in kidney transplantation. Results of a national survey. Actas Urol Esp. 2015;39(5):303–9. Sutherland LM, Middleton PF, Anthony A, Hamdorf J, Cregan P, Scott D, et al. Surgical simulation: a systematic review. Ann Surg. 2006;243(3):291–300. Sáenz Medina J, Asuero de Lis MS, Correa Gorospe C, Cuevas B, Gómez Dos Santos V, Linares Quevedo AI, et al. Experimental models for research and training in renal transplant. Actas Urol Esp. 2008;32(1):83–90. Kobayashi E, Hishikawa S, Teratani T, Lefor AT. The pig as a model for translational research: overview of porcine animal models at Jichi Medical University. Transpl Res. 2012;1(1):8. Bestard Vallejo JE, Raventós Busquets CX, Celma Doménech A, Rosal Fontana M, Esteve M, Morote RJ. Pig model in experimental renal transplant surgery. Actas Urol Esp. 2008;32(1):91–101. Prasad Rai B, Tang B, Eisma R, Soames RW, Wen H, Nabi G. A qualitative assessment of human cadavers embalmed by Thiel’s method used in laparoscopic training for renal resection. Anat Sci Educ. 2012;5(3):182–6. Wedel T, Ackermann J, Hagedorn H, Mettler L, Maass N, Alkatout I. Educational training in laparoscopic gynecological surgery based on ethanol-glycerol-lysoformin-preserved body donors. Ann Anat. 2019;221:157–64. Menon M, Abaza R, Sood A, Ahlawat R, Ghani KR, Jeong W, et al. Robotic kidney transplantation with regional hypothermia: evolution of a novel procedure utilizing the IDEAL guidelines (IDEAL phase 0 and 1). Eur Urol. 2014;65(5):1001–9. He B, Mou L, De Roo R, Musk GC, Hamdorf JM. Evaluation of three-dimensional versus conventional laparoscopy for kidney transplant procedures in a human cadaveric model. Exp Clin Transplant. 2017;15(5):497–503. Eltemamy M, Garisto J, Miller E, Wee A, Kaouk J. Single port robotic extra-peritoneal dual kidney transplantation: initial pre-clinical experience and description of the technique. Urology. 2019. Sharma M, Macafee D, Horgan AF. Basic laparoscopic skills training using fresh frozen cadaver: a randomized controlled trial. Am J Surg. 2013;206(1):23–31. •• Ottone N, Vargas C, Fuentes R, Del Sol M. Walter Thiel’s embalming method. Review of solutions and applications in different fields of biomedical research. Int J Morphol. 2016;34(4):1442–54. Reviews in detail other uses for surgical simulation of cadavers embalmed with TEM. Wolff K-D, Kesting M, Mücke T, Rau A, Hölzle F. Thiel embalming technique: a valuable method for microvascular exercise and teaching of flap raising. Microsurgery. 2008;28(4):273–8. Okada R, Tsunoda A, Momiyama N, Kishine N, Kitamura K, Kishimoto S, et al. Thiel’s method of embalming and its usefulness in surgical assessments. Nihon Jibiinkoka Gakkai Kaiho. 2012;115(8):791–4. Nielsen GD, Larsen ST, Wolkoff P. Re-evaluation of the WHO (2010) formaldehyde indoor air quality guideline for cancer risk assessment. Arch Toxicol. 2017;91(1):35–61. Thiel W. The preservation of the whole corpse with natural color. Ann Anat. 1992;174(3):185–95. Thiel W. Supplement to the conservation of an entire cadaver according to W. Thiel. Ann Anat. 2002;184(3):267–9. Liao P-Y, Wang Z-G. Thiel-embalming technique: investigation of possible modification in embalming tissue as evaluation model for radiofrequency ablation. J Biomed Res. 2019. Pichler W, Tesch NP, Grechenig W, Tanzer K, Grasslober M. Anatomical variations of the flexor hallucis longus muscle and the consequences for tendon transfer. A cadaver study. Surg Radiol Anat SRA. 2005;27(3):227–31. Kappler UA, Constantinescu MA, Büchler U, Vögelin E. Anatomy of the proximal cutaneous perforator vessels of the gracilis muscle. Br J Plast Surg. 2005;58(4):445–8. Saito T, Yoshimoto M, Yamamoto Y, Miyaki T, Itoh M, Shimizu S, et al. The medial branch of the lateral branch of the posterior ramus of the spinal nerve. Surg Radiol Anat SRA. 2006;28(3):228–34. Desroches J, Grabs U, Grabs D. Selective ultrasound guided pectoral nerve targeting in breast augmentation: how to spare the brachial plexus cords? Clin Anat. 2013;26(1):49–55. González-Arnay E, Jiménez-Sánchez L, García-Simón D, Valdés-Vilches L, Salazar-Zamorano CH, Boada-Pié S, et al. Ultrasonography-guided anterior approach for axillary nerve blockade: an anatomical study. Clin Anat. 2019. Szűcs Z, László CJ, Baksa G, László I, Varga M, Szuák A, et al. Suitability of a preserved human cadaver model for the simulation of facemask ventilation, direct laryngoscopy and tracheal intubation: a laboratory investigation. Br J Anaesth. 2016;116(3):417–22. De Crop A, Bacher K, Van Hoof T, Smeets PV, Smet BS, Vergauwen M, et al. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study. Radiology. 2012;262(1):298–304. Pilsl U, Rosmarin W, Anderhuber F. The premaxillary space: a location for filler injection? Dermatol Surg. 2014;40(3):301–4. McLeod H, Cox BF, Robertson J, Duncan R, Matthew S, Bhat R, et al. Human Thiel-embalmed cadaveric aortic model with perfusion for endovascular intervention training and medical device evaluation. Cardiovasc Intervent Radiol. 2017;40(9):1454–60. Lim R, Tay SC, Yam A. Radial nerve injury during double plating of a displaced intercondylar fracture. J Hand Surg. 2012;37(4):669–72. Peuker ET, Werkmeister R, Pera F, Joos U, Filler TJ. Surgical procedures in mouth, jaw and facial surgery in Thiel embalmed body donors. Mund- Kiefer- Gesichtschirurgie MKG. 2001;5(2):141–3. Ruiz-Tovar J, Prieto-Nieto I, García-Olmo D, Clascá F, Enriquez P, Vilallonga R, et al. Correction to: Training courses in laparoscopic bariatric surgery on cadaver Thiel: results of a satisfaction survey on students and professors. Obes Surg. 2019 Jul 1 [cited 2019 Oct 7]; Available from: http://link.springer.com/10.1007/s11695-019-04050-9. Eisma R, Mahendran S, Majumdar S, Smith D, Soames RW. A comparison of Thiel and formalin embalmed cadavers for thyroid surgery training. Surg J R Coll Surg Edinb Irel. 2011;9(3):142–6.