Bone reactions adjacent to titanium implants subjected to static load of different duration. A study in the dog (III)

Clinical Oral Implants Research - Tập 12 Số 6 - Trang 552-558 - 2001
Klaus Gotfredsen1, Tord Berglundh2, Jan Lindhe2
1Department of Prosthetic Dentistry, School of Dentistry, Faculty of Health Sciences, University of Copenhagen, Denmark
2Department of Periodontology, Faculty of Odontology, University of Göteborg, Sweden

Tóm tắt

Abstract: The aim of the present experiment was to study the effect of a long‐standing lateral static load on the peri‐implant bone. Three beagle dogs were used. The mandibular premolars were extracted and 12 weeks later 3 titanium implants (ITI® Dental Implant System) were installed in each quadrant. Crowns were fitted to all implants 12 weeks after the installation procedure. The anterior and central crowns were fused and connected to the posterior crown by an expansion screw. In the right side of the mandible, the expansion screws were activated every 2 weeks during a 46‐week period. During the last 10 weeks of this period, an expansion force similar to that of the right side was applied in the left. The animals were sacrificed and block biopsies of each implant site harvested and prepared for histological analysis. Sites subjected to 10 weeks or 46 weeks of lateral load had a similar (i) distribution of bone markers (ii) proportion of bone density and (iii) degree of bone‐to‐implant contact. The proportion of fluorochromes was higher at sites subjected to 10 weeks of loading than at sites subjected to 46 weeks of loading.

Từ khóa


Tài liệu tham khảo

10.1016/S0889-5406(98)70211-2

10.1034/j.1600-0501.1997.080604.x

10.1111/j.1600-0714.1982.tb00172.x

10.1034/j.1600-0501.2001.012001001.x

Gotfredsen K., 2001, Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. A study in the dog (II), Clinical Oral Implants Research

Holmes D.C., 1997, Influence of bone quality on stress distribution for endosseous implants, Journal of Oral Implantology, 23, 104

Karnowsky M.J., 1965, A formaldehyde‐glutaraldehyde fixative of high osmolarity for use in electron microscopy, Journal of Cell Biology, 3, 112

10.1016/0002-9416(84)90301-4

Roberts W.E., 1989, Rigid endosseous implants for orthodontic and orthopedic anchorage, Angle Orthodontist, 59, 247

Stegaroiu R., 1998, Influence of restoration type on stress distribution in bone around implants: a three‐dimensional finite element analysis, International Journal of Oral and Maxillofacial Implants, 13, 82

10.1034/j.1600-0501.1997.080208.x

10.1034/j.1600-0501.1998.090509.x