Blood flows in end-to-end arteriovenous fistulas: Unsteady and steady state numerical investigations of three patient-specific cases

Biocybernetics and Biomedical Engineering - Tập 37 - Trang 528-539 - 2017
Daniel Jodko1, Damian Obidowski1, Piotr Reorowicz1, Krzysztof Jóźwik1
1Lodz University of Technology, Institute of Turbomachinery, Lodz, Poland

Tài liệu tham khảo

Brescia, 1966, Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula, N Engl J Med, 275, 1089, 10.1056/NEJM196611172752002 US Renal Data System Technical Report, 2014 Besarab, 2007, The native arteriovenous fistula in 2007. Surveillance and monitoring, J Nephrol, 20, 656 Stanziale, 2011, Arteriovenous fistula: end-to-end or end-to-side anastomosis?, Hemodial Int, 15, 100, 10.1111/j.1542-4758.2010.00503.x Crosetto, 2011, Fluid-structure interaction simulation of aortic blood flow, Comput Fluids, 43, 46, 10.1016/j.compfluid.2010.11.032 Ene-Iordache, 2013, Effect of anastomosis angle on the localization of disturbed flow in ‘side-to-end’ fistulae for haemodialysis access, Nephrol Dial Transplant, 28, 997, 10.1093/ndt/gfs298 McGah, 2013, Incomplete restoration of homeostatic shear stress within arteriovenous fistulae, J Biomech Eng, 135, 51, 10.1115/1.4023133 McGah, 2014, Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula, Biomech Model Mechanobiol, 13, 679, 10.1007/s10237-013-0527-7 Jodko, 2014, Simulations of the blood flow in the arterio-venous fistula for haemodialysis, Acta Bioeng Biomech, 16, 69 Reorowicz, 2014, Numerical simulations of the blood flow in the patient-specific arterial cerebral circle region, J Biomech, 47, 1642, 10.1016/j.jbiomech.2014.02.039 Celik, 2008, Procedure for estimation and reporting of uncertainty due to discretization in CFD applications, J Fluids Eng, 130, 1 Browne, 2015, Experimental and numerical analysis of the bulk flow parameters within an arteriovenous fistula, Cardiovasc Eng Technol, 6, 450, 10.1007/s13239-015-0246-6 Jodko, 2014, Angular position determination of heart valves in the pediatric ventricular assist device with use of computational fluid dynamics, Curr Probl Biomech, 8, 57 Pietura, 2005, Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access, Eur J Radiol, 55, 113, 10.1016/j.ejrad.2004.09.010 Obidowski, 2011 Corpataux, 2002, Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access, Nephrol Dial Transplant, 17, 1057, 10.1093/ndt/17.6.1057 ANSYS CFX Theory Guide. ANSYS Release 15.0 ANSYS Inc. Menter, 1994, Two-equation eddy-viscosity turbulence models for engineering applications, Am Inst Aeronaut Astronaut J, 32, 1598, 10.2514/3.12149 Menter, 2003, Ten years of industrial experience with the SST turbulence model Shin, 2002, Measurement of blood viscosity using mass-detecting sensor, Biosens Bioelectron, 17, 383, 10.1016/S0956-5663(01)00314-1 Johnston, 2006, Non-Newtonian blood flow in human right coronary arteries: transient simulations, J Biomech, 39, 1116, 10.1016/j.jbiomech.2005.01.034 Jozwik, 2010, Numerical simulations of the blood flow through vertebral arteries, J Biomech, 43, 177, 10.1016/j.jbiomech.2009.09.026 Kenner, 1989, The measurement of blood density and its meaning, Basic Res Cardiol, 84, 111, 10.1007/BF01907921 Sivanesan, 1999, Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study, J Biomech, 32, 915, 10.1016/S0021-9290(99)00088-3 Ene-Iordache, 2012, Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis, Nephrol Dial Transplant, 27, 358, 10.1093/ndt/gfr342 Botti, 2013, Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis, Cardiovasc Eng Technol, 4, 485, 10.1007/s13239-013-0162-6 Konner, 2003, The arteriovenous fistula, J Am Soc Nephrol, 14, 1669, 10.1097/01.ASN.0000069219.88168.39 Kharboutly, 2010, Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis, Med Eng Phys, 32, 111, 10.1016/j.medengphy.2009.10.013 Dixon, 2006, Why don’t fistulas mature?, Kidney Int, 70, 1413, 10.1038/sj.ki.5001747 Womersley, 1955, Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known, J Physiol (Lond), 127, 553, 10.1113/jphysiol.1955.sp005276 Decorato, 2014, Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula, Int J Numer Methods Biomed Eng, 30, 143, 10.1002/cnm.2595 Chiu, 2011, Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives, Physiol Rev, 91, 327, 10.1152/physrev.00047.2009 Chatzizisis, 2007, Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling, J Am Coll Cardiol, 49, 2379, 10.1016/j.jacc.2007.02.059 Arora, 2004, A tensor-based measure for estimating blood damage, Artif Organs, 28, 1002, 10.1111/j.1525-1594.2004.00072.x Morbiducci, 2009, Blood damage safety of prosthetic heart valves. Shear-induced platelet activation and local flow dynamics: a fluid-structure interaction approach, J Biomech, 42, 1952, 10.1016/j.jbiomech.2009.05.014 Wang, 2004, Wave propagation in a model of the arterial circulation, J Biomech, 37, 457, 10.1016/j.jbiomech.2003.09.007 Caroli, 2013, Validation of patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients, Kidney Int, 84, 1237, 10.1038/ki.2013.188