Bipolar versus high-density surface electromyography for evaluating risk in fatiguing frequency-dependent lifting activities

Applied Ergonomics - Tập 95 - Trang 103456 - 2021
Tiwana Varrecchia1,2, Alberto Ranavolo1, Silvia Conforto2, Alessandro Marco De Nunzio3,4, Michail Arvanitidis5, Francesco Draicchio1, Deborah Falla5
1Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, INAIL, Monte Porzio Catone, 00040, Rome, Italy
2Department of Engineering, Roma Tre University, Via Vito Volterra 62, Roma, Lazio, Italy
3LUNEX International University of Health, Exercise and Sports, 50, Avenue du Parc des Sports, Differdange, 4671, Luxembourg
4Luxembourg Health & Sport Sciences Research Institute A.s.b.l., 50, Avenue du Parc des Sports, Differdange 4671, Luxembourg
5Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Edgbaston, B152TT, United Kingdom

Tài liệu tham khảo

Ajoudani, 2014, Exploring teleimpedance and tactile feedback for intuitive control of the pisa/iit softhand, IEEE Trans. Haptics, 7(2), 203, 10.1109/TOH.2014.2309142 Ajoudani, 2020, Smart collaborative systems for enabling flexible and ergonomic work practices [industry activities], IEEE Robot. Autom. Mag., 27, 169, 10.1109/MRA.2020.2985344 Alberto, 2018, Wearable monitoring devices for biomechanical risk assessment at work: current status and future challenges-A systematic review, Int. J. Environ. Res. Publ. Health, 15, 2001, 10.3390/ijerph15092001 Antwi-Afari, 2017, Biomechanical analysis of risk factors for work-related musculoskeletal disorders during repetitive lifting task in construction workers, Autom. ConStruct., 83, 41, 10.1016/j.autcon.2017.07.007 Bakker, 2009, Spinal mechanical load as a risk factor for low back pain: a systematic review of prospective cohort studies, Spine, 34, E281, 10.1097/BRS.0b013e318195b257 Barbero, 2012 Borg, 1982, Psychophysical bases of perceived exertion, Med. Sci. Sports Exerc., 14, 377, 10.1249/00005768-198205000-00012 Brazier, 1992, Validating the SF-36 health survey questionnaire: new outcome measure for primary care, BMJ, 305, 160, 10.1136/bmj.305.6846.160 Butler, 2009, The interpretation of abdominal wall muscle recruitment strategies change when the electrocardiogram (ECG) is removed from the electromyogram (EMG), J. Electromyogr. Kinesiol., 19, 102, 10.1016/j.jelekin.2007.10.004 Cè, 2020, Peripheral fatigue: new mechanistic insights from recent technologies, Eur. J. Appl. Physiol., 120, 17, 10.1007/s00421-019-04264-w Cifrek, 2009, Surface EMG based muscle fatigue evaluation in biomechanics, Clin. Biomech., 24, 327, 10.1016/j.clinbiomech.2009.01.010 Clark, 2003, Gender differences in skeletal muscle fatigability are related to contraction type and EMG spectral compression, J. Appl. Physiol., 94, 2263, 10.1152/japplphysiol.00926.2002 Da Xu, 2018, Industry 4.0: state of the art and future trends, Int. J. Prod. Res., 56, 2941, 10.1080/00207543.2018.1444806 Del Vecchio, 2020, Analysis of motor unit discharge characteristics from high-density surface EMG signals, J. Electromyogr. Kinesiol., 53, 10.1016/j.jelekin.2020.102426 Dempsey, 2002, Usability of the revised NIOSH lifting equation, Ergonomics, 45, 817, 10.1080/00140130210159977 Drake, 2006, Elimination of electrocardiogram contamination from electromyogram signals: an evaluation of currently used removal techniques, J. Electromyogr. Kinesiol., 16, 175, 10.1016/j.jelekin.2005.07.003 Faiz, 2014, VAS--visuell analog skala [VAS--visual analog scale], Tidsskr. Nor. Laegeforen, 134, 323, 10.4045/tidsskr.13.1145 Falla, 2017, Muscle pain induces a shift of the spatial distribution of upper trapezius muscle activity during a repetitive task: a mechanism for perpetuation of pain with repetitive activity?, Clin. J. Pain, 33, 1006, 10.1097/AJP.0000000000000513 Falla, 2008, Non-uniform adaptation of motor unit discharge rates during sustained static contraction of the upper trapezius muscle, Exp. Brain Res., 191, 363, 10.1007/s00221-008-1530-6 Falla, 2020, New insights into pain-related changes in muscle activation revealed by high-density surface electromyography, J. Electromyogr. Kinesiol., 52, 10.1016/j.jelekin.2020.102422 Falla, 2014, Reduced task-induced variations in the distribution of activity across back muscle regions in individuals with low back pain, Pain, 155, 944, 10.1016/j.pain.2014.01.027 Farina, 2008, The change in spatial distribution of upper trapezius muscle activity is correlated to contraction duration, J. Electromyogr. Kinesiol., 18, 16, 10.1016/j.jelekin.2006.08.005 Farina, 2003, A novel approach for estimating muscle fiber conduction velocity by spatial and temporal filtering of surface EMG signals, IEEE Trans. Biomed. Eng., 50, 1340, 10.1109/TBME.2003.819847 Farina, 2004, Methods for estimating muscle fibre conduction velocity from surface electromyographic signals, Med. Biol. Eng. Comput., 42, 432, 10.1007/BF02350984 Farina, 2016, Principles of motor unit physiology evolve with advances in technology, Physiology, 31, 83, 10.1152/physiol.00040.2015 Faul, 2007, G∗Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences, Behav. Res. Methods, 39, 175, 10.3758/BF03193146 Filho, 2013, Effect of different rest intervals, between sets, on muscle performance during leg press exercise, in trained older women, J. Sports Sci. Med., 12, 138 Gallina, 2013, Spatial localization of electromyographic amplitude distributions associated to the activation of dorsal forearm muscles, Front. Physiol., 4, 367, 10.3389/fphys.2013.00367 Garg, 2014, The NIOSH lifting equation and low-back pain, Part 1: association with low-back pain in the backworks prospective cohort study, Hum. Factors, 56, 6, 10.1177/0018720813486669 Garg, 2014, The NIOSH lifting equation and low-back pain, Part 2: association with seeking care in the backworks prospective cohort study, Hum. Factors, 56, 44, 10.1177/0018720813491284 Gordon, 2013, Locomotor adaptation to a soleus EMG-controlled antagonistic exoskeleton, J. Neurophysiol., 109, 1804, 10.1152/jn.01128.2011 Griffith, 2012, Individual participant data meta-analysis of mechanical workplace risk factors and low back pain, Am. J. Publ. Health, 102, 309, 10.2105/AJPH.2011.300343 Hahne, 2014, Linear and nonlinear regression techniques for simultaneous and proportional myoelectric control, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 269, 10.1109/TNSRE.2014.2305520 Hoogendoorn, 2002, High physical work load and low job satisfaction increase the risk of sickness absence due to low back pain: results of a prospective cohort study, Occup. Environ. Med., 59, 323, 10.1136/oem.59.5.323 Kapelner, 2020, Neuro-musculoskeletal mapping for man-machine interfacing, Sci. Rep., 10, 5834, 10.1038/s41598-020-62773-7 Kapelner, 2019, Predicting wrist kinematics from motor unit discharge timings for the control of active prosthese, J. NeuroEng. Rehabil., 16, 47, 10.1186/s12984-019-0516-x Kiguchi, 2012, An EMG-based control for an upper-limb power-assist exoskeleton robot, IEEE Trans. Syst. Man Cybern. B Cybern., 42, 1064, 10.1109/TSMCB.2012.2185843 Kwon, 2011, Systematic review: occupational physical activity and low back pain, Occup. Med. (Lond.), 61, 541, 10.1093/occmed/kqr092 Lavender, 2009, Does the asymmetry multiplier in the 1991 NIOSH lifting equation adequately control the biomechanical loading of the spine?, Ergonomics, 52, 71, 10.1080/00140130802480802 Lobov, 2018, Latent factors limiting the performance of sEMG-interfaces, Sensors, 18, 1122, 10.3390/s18041122 Lotti, 2020, Adaptive model-based myoelectric control for a SoftWearable arm exosuit: a new generation of wearable robot control, IEEE Robot. Autom. Mag., 27, 43, 10.1109/MRA.2019.2955669 Lu, 2014, Efficacy of the revised NIOSH lifting equation to predict risk of low-back pain associated with manual lifting: a one-year prospective study, Hum. Factors, 56, 73, 10.1177/0018720813513608 Madeleine, 2006, Experimental muscle pain changes the spatial distribution of upper trapezius muscle activity during sustained contraction, Clin. Neurophysiol., 117, 2436, 10.1016/j.clinph.2006.06.753 Martinez-Valdes, 2019, Rowers with a recent history of low back pain engage different regions of the lumbar erector spinae during rowing, J. Sci. Med. Sport, 22, 1206, 10.1016/j.jsams.2019.07.007 Merletti, 1991, Indices of muscle fatigue, J. Electromyogr. Kinesiol., 1, 20, 10.1016/1050-6411(91)90023-X Merletti, 2004 Merletti, 2016 Muscillo, 2007, Classification of motor activities through derivative dynamic time warping applied on accelerometer data, Conf Proc IEEE Eng Med Biol Soc, 4930 Negro, 2016, Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation, J. Neural. Eng., 13, 10.1088/1741-2560/13/2/026027 Nizamis, 2020, Characterization of forearm muscle activation in duchenne muscular dystrophy via high-density electromyography: a case study on the implications for myoelectric control, Front. Neurol., 11, 231, 10.3389/fneur.2020.00231 Ranavolo, 2020, The sensor-based biomechanical risk assessment at the base of the need for revising of standards for human ergonomics, Sensors, 20, 5750, 10.3390/s20205750 Ranavolo, 2018, Erratum: Alberto, R. et al., Wearable monitoring devices for biomechanical risk assessment at work: current status and future challenges-A systematic review, Int. J. Environ. Res. Publ. Health, 15, 2001, 10.3390/ijerph15092001 Ranavolo, 2020, Critical issues and imminent challenges in the use of sEMG in return-to-work rehabilitation of patients affected by neurological disorders in the epoch of human-robot collaborative technologies, Front. Neurol., 11, 10.3389/fneur.2020.572069 Ranavolo, 2015, A new muscle co-activation index for biomechanical load evaluation in work activities, Ergonomics, 58, 966, 10.1080/00140139.2014.991764 Ranavolo, 2017, Mechanical lifting energy consumption in work activities designed by means of the "revised NIOSH lifting equation, Ind. Health, 55, 444, 10.2486/indhealth.2017-0075 Ranavolo, 2018, Surface electromyography for risk assessment in work activities designed using the “revised NIOSH lifting equation”, Int. J. Ind. Ergon., 68, 34, 10.1016/j.ergon.2018.06.003 Roche, 2014, Prosthetic myoelectric control strategies: a clinical perspective, Curr Surg Rep, 2, 44, 10.1007/s40137-013-0044-8 Sanderson, 2019, Variation in the spatial distribution of erector spinae activity during a lumbar endurance task in people with low back pain, J. Anat., 10.1111/joa.12935 Serrao, 2012, Gait pattern in inherited cerebellar ataxias, Cerebellum, 11, 194, 10.1007/s12311-011-0296-8 Stegeman, 2012, High-density surface EMG: techniques and applications at a motor unit level, Biocybern. Biomed. Eng., 32, 3, 10.1016/S0208-5216(12)70039-6 Tsuboi, 2013, Age-related sex differences in erector spinae muscle endurance using surface electromyographic power spectral analysis in healthy humans, Spine J., 13, 1928, 10.1016/j.spinee.2013.06.060 Tucker, 2009, Electromyographic mapping of the erector spinae muscle with varying load and during sustained contraction, J. Electromyogr. Kinesiol., 19, 373, 10.1016/j.jelekin.2007.10.003 van Dieen, 1993, Spectral analysis of erector spinae EMG during intermittent isometric fatiguing exercise, Ergonomics, 36, 407, 10.1080/00140139308967898 Varrecchia, 2020, Lifting activity assessment using kinematic features and neural networks, Appl. Sci., 10, 1989, 10.3390/app10061989 Varrecchia, 2018, Lifting activity assessment using surface electromyographic features and neural networks, Int. J. Ind. Ergon., 66, 1, 10.1016/j.ergon.2018.02.003 Wai, 2010, Causal assessment of occupational lifting and low back pain: results of a systematic review, Spine J., 10, 554, 10.1016/j.spinee.2010.03.033 Waters, 2011, Efficacy of the revised NIOSH lifting equation to predict risk of low back pain due to manual lifting: expanded cross-sectional analysis, J. Occup. Environ. Med., 53, 1061, 10.1097/JOM.0b013e31822cfe5e Waters, 1994 Waters, 1993, Revised NIOSH equation for the design and evaluation of manual lifting tasks, Ergonomics, 36, 749, 10.1080/00140139308967940 Winter, 2009