Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses

Journal of the Formosan Medical Association - Tập 115 - Trang 794-800 - 2016
Aaron Yu-Jen Wu1, Jui-Ting Hsu2,3, Winston Chee4, Yun-Te Lin2, Lih-Jyh Fuh2, Heng-Li Huang2,3
1Department of Dentistry, Chang Gung Memorial Hospital and College of Medicine, Chang Gung University, Niao-Sung, Kaohsiung, Taiwan
2School of Dentistry, China Medical University, Taichung, Taiwan
3Department of Bioinformatics and Medical Engineering, Asia University, Wufeng, Taichung, Taiwan
4Ostrow School of Dentistry, University of Southern California, Los Angeles, CA, USA

Tài liệu tham khảo

Fretwurst, 2015, A prospective study of factors influencing morbidity after iliac crest harvesting for oral onlay grafting, J Craniomaxillofac Surg, 43, 705, 10.1016/j.jcms.2015.03.023 Hsu, 2009, Bone strain and interfacial sliding analyses of platform switching and implant diameter on an immediately loaded implant: experimental and three-dimensional finite element analyses, J Periodontol, 80, 1125, 10.1902/jop.2009.090013 Isidor, 2006, Influence of forces on peri-implant bone, Clin Oral Implants Res, 17, 8, 10.1111/j.1600-0501.2006.01360.x Qian, 2012, Reasons for marginal bone loss around oral implants, Clin Implant Dent Relat Res, 14, 792, 10.1111/cid.12014 Allum, 2008, The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study, Clin Oral Implants Res, 19, 553, 10.1111/j.1600-0501.2007.01395.x Albrektsson, 2007, Survival of NobelDirect implants: an analysis of 550 consecutively placed implants at 18 different clinical centers, Clin Implant Dent Relat Res, 9, 65, 10.1111/j.1708-8208.2007.00054.x Pabst, 2015, Analysis of implant-failure predictors in the posterior maxilla: a retrospective study of 1395 implants, J Craniomaxillofac Surg, 43, 414, 10.1016/j.jcms.2015.01.004 Lee, 2013, Long-term retrospective study of narrow implants for fixed dental prostheses, Clin Oral Implants Res, 24, 847, 10.1111/j.1600-0501.2012.02472.x Maiorana, 2015, Clinical and radiographic evaluation of early loaded narrow-diameter implants: 3 years follow-up, Clin Oral Implants Res, 26, 77, 10.1111/clr.12281 Lee, 2005, Effect of implant size and shape on implant success rates: a literature review, J Prosthet Dent, 94, 377, 10.1016/j.prosdent.2005.04.018 Degidi, 2008, Clinical outcome of narrow diameter implants: a retrospective study of 510 implants, J Oral Implantol, 79, 49 Sennerby, 2008, Short-term clinical results of Nobel Direct implants: a retrospective multicentre analysis, Clin Oral Implants Res, 19, 219, 10.1111/j.1600-0501.2007.01410.x Jackson, 2011, Small diameter implants: Specific indications and considerations for the posterior mandible: a case report, J Oral Implantol, 37, 156, 10.1563/AAID-JOI-D-09-00142.1 Romeo, 2006, Clinical and radiographic evaluation of small-diameter (3.3-mm) implants followed for 1–7 years: a longitudinal study, Clin Oral Implants Res, 17, 139, 10.1111/j.1600-0501.2005.01191.x Maló, 2011, Implants (3.3-mm diameter) for the rehabilitation of edentulous posterior regions: a retrospective clinical study with up to 11 years of follow-up, Clin Implant Dent Relat Res, 13, 95, 10.1111/j.1708-8208.2009.00188.x Wu, 2014, Biomechanical effects of the implant material and implant–abutment interface in immediately loaded small-diameter implants, Clin Oral Investig, 18, 1335, 10.1007/s00784-013-1099-8 Bourauel, 2012, Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants, Biomed Tech (Berl), 57, 21, 10.1515/bmt-2011-0047 Chong, 2009, Effect of implant design on initial stability of tapered implants, J Oral Implantol, 35, 130, 10.1563/1548-1336-35.3.130 Misch, 1999, Density of bone: effect on surgical approach and healing, 372 Hahn, 1999, Clinical uses of osteotomes, J Oral Implantol, 25, 23, 10.1563/1548-1336(1999)025<0023:CUOO>2.3.CO;2 Alsaadi, 2007, A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment, J Clin Periodontol, 34, 359, 10.1111/j.1600-051X.2007.01047.x Steiner, 2009, In-vitro evaluation of a mechanical testing chewing simulator, Dent Mater, 25, 494, 10.1016/j.dental.2008.09.010 Alkan, 2004, Influence of occlusal forces on stress distribution in preloaded dental implant screws, J Prosthet Dent, 91, 319, 10.1016/j.prosdent.2004.01.016 Niinomi, 1998, Mechanical properties of biomedical titanium alloys, Mater Sci Eng, 243, 231, 10.1016/S0921-5093(97)00806-X Cavit Çehreli, 2004, Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis, Clin Oral Implants Res, 15, 481, 10.1111/j.1600-0501.2004.01025.x Östman, 2007, Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a 1-year prospective clinical and radiographic study, Clin Oral Implants Res, 18, 409, 10.1111/j.1600-0501.2007.01346.x Van de Velde, 2009, Two-year outcome with Nobel Direct implants: a retrospective radiographic and microbiologic study in 10 patients, Clin Implant Dent Relat Res, 11, 183, 10.1111/j.1708-8208.2008.00112.x Geng, 2001, Application of finite element analysis in implant dentistry: a review of the literature, J Prosthet Dent, 85, 585, 10.1067/mpr.2001.115251 Murakami, 2014, Finite element contact analysis as a critical technique in dental biomechanics: a review, J Prosthodont Res, 58, 92, 10.1016/j.jpor.2014.03.001