Biodegradable magnesium alloys for orthopaedic applications: A review on corrosion, biocompatibility and surface modifications

Materials Science and Engineering: C - Tập 68 - Trang 948-963 - 2016
Sankalp Agarwal1,2, James F. Curtin2, Brendan Duffy1, Swarna Jaiswal1
1Centre for Research in Engineering and Surface Technology, FOCAS Institute, Dublin Institute of Technology, Ireland
2School of Food Science and Environmental Health, Cathal Brugha Street, Dublin Institute of Technology, Ireland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Poinern, 2012, Biomedical magnesium alloys: a review of material properties, surface modifications and potential as a biodegradable orthopaedic implant, Am. J. Biomed. Eng., 2, 218, 10.5923/j.ajbe.20120206.02

Staiger, 2006, Magnesium and its alloys as orthopedic biomaterials: a review, Biomaterials, 27, 1728, 10.1016/j.biomaterials.2005.10.003

Murugan, 2005, Development of nanocomposites for bone grafting, Compos. Sci. Technol., 65, 2385, 10.1016/j.compscitech.2005.07.022

Ye, 2015, Mechanical properties and phase transition of biomedical titanium alloy strips with initial quasi-single phase state under high-energy electropulses, J. Mech. Behav. Biomed. Mater., 42, 100, 10.1016/j.jmbbm.2014.11.009

Witte, 2010, The history of biodegradable magnesium implants: a review, Acta Biomater., 6, 1680, 10.1016/j.actbio.2010.02.028

Crubézy, 1998, False teeth of the Roman world, Nature, 391, 29, 10.1038/34067

Ratner, 2004

Zheng, 2014, Biodegradable metals, Mater. Sci. Eng. R. Rep., 77, 1, 10.1016/j.mser.2014.01.001

Ye, 2015, Effects of high-energy electro-pulsing treatment on microstructure, mechanical properties and corrosion behavior of Ti–6Al–4V alloy, Mater. Sci. Eng. C, 49, 851, 10.1016/j.msec.2015.01.081

Rashmir-Raven, 1995, The response of cancellous and cortical canine bone to hydroxylapatite-coated and uncoated titanium rods, J. Appl. Biomater., 6, 237, 10.1002/jab.770060404

Nagels, 2003, Stress shielding and bone resorption in shoulder arthroplasty, J. Shoulder Elb. Surg., 12, 35, 10.1067/mse.2003.22

Ryan, 2006, Fabrication methods of porous metals for use in orthopaedic applications, Biomaterials, 27, 2651, 10.1016/j.biomaterials.2005.12.002

Krishna, 2008, Engineered porous metals for implants, JOM, 60, 45, 10.1007/s11837-008-0059-2

Lhotka, 2003, Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements, J. Orthop. Res., 21, 189, 10.1016/S0736-0266(02)00152-3

Walker, 2014, Magnesium biomaterials for orthopedic application: a review from a biological perspective, J. Biomed. Mater. Res. B Appl. Biomater., 102, 1316, 10.1002/jbm.b.33113

Ducheyne, 1980, Effect of hydroxyapatite impregnation on skeletal bonding of porous coated implants, J. Biomed. Mater. Res., 14, 225, 10.1002/jbm.820140305

Yoshikawa, 2008, Interconnected porous hydroxyapatite ceramics for bone tissue engineering, J. R. Soc. Interface, 13, 1

Itoh, 2004, Development of a novel biomaterial, hydroxyapatite/collagen (HAp/col) composite for medical use, Bio-Med. Mater. Eng., 15, 29

Rojaee, 2013, Controlling the degradation rate of AZ91 magnesium alloy via sol–gel derived nanostructured hydroxyapatite coating, Mater. Sci. Eng. C, 33, 3817, 10.1016/j.msec.2013.05.014

Zahrani, 2011, Sol-gel derived nanocrystalline fluoridated hydroxyapatite powders and nanostructured coatings for tissue engineering applications, Metall. Mater. Trans. A, 42, 3291, 10.1007/s11661-010-0465-2

Gadow, 2010, Hydroxyapatite coatings for biomedical applications deposited by different thermal spray techniques, Surf. Coat. Technol., 205, 1157, 10.1016/j.surfcoat.2010.03.059

Swetha, 2010, Biocomposites containing natural polymers and hydroxyapatite for bone tissue engineering, Int. J. Biol. Macromol., 47, 1, 10.1016/j.ijbiomac.2010.03.015

Guo, 2014, Synthetic biodegradable functional polymers for tissue engineering: a brief review, SCIENCE CHINA Chem., 57, 490, 10.1007/s11426-014-5086-y

Gunatillake, 2003, Biodegradable synthetic polymers for tissue engineering, Eur. Cells Mater., 5, 1, 10.22203/eCM.v005a01

Kohane, 2008, Polymeric biomaterials in tissue engineering, Pediatr. Res., 63, 487, 10.1203/01.pdr.0000305937.26105.e7

Zhao, 2012, Improved corrosion resistance and cytocompatibility of magnesium alloy by two-stage cooling in thermal treatment, Corros. Sci., 59, 360, 10.1016/j.corsci.2012.03.020

Witte, 2005, In vivo corrosion of four magnesium alloys and the associated bone response, Biomaterials, 26, 3557, 10.1016/j.biomaterials.2004.09.049

Ghali, 2010

Song, 2005, Recent progress in corrosion and protection of magnesium alloys, Adv. Eng. Mater., 7, 563, 10.1002/adem.200500013

Zhang, 2010, Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial, J. Mater. Sci. Mater. Med., 21, 2151, 10.1007/s10856-010-4070-0

Song, 2012, Corrosion and electrochemical evaluation of coated magnesium alloys, Corros. J. Sci. Eng., 68, 015005

Song, 2007, Control of biodegradation of biocompatable magnesium alloys, Corros. Sci., 49, 1696, 10.1016/j.corsci.2007.01.001

Xin, 2011, In vitro studies of biomedical magnesium alloys in a simulated physiological environment: a review, Acta Biomater., 7, 1452, 10.1016/j.actbio.2010.12.004

Rettig, 2008, Time-dependent electrochemical characterization of the corrosion of a magnesium rare-earth alloy in simulated body fluids, J. Biomed. Mater. Res. A, 85, 167, 10.1002/jbm.a.31550

Xin, 2008, Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environment, Acta Biomater., 4, 2008, 10.1016/j.actbio.2008.05.014

Zeng, 2008, Progress and challenge for magnesium alloys as biomaterials, Adv. Eng. Mater., 10, B3, 10.1002/adem.200800035

Zeng, 2006, Review of studies on corrosion of magnesium alloys, Trans. Nonferrous Metals Soc. China, 16, s763, 10.1016/S1003-6326(06)60297-5

Song, 2003, Understanding magnesium corrosion—a framework for improved alloy performance, Adv. Eng. Mater., 5, 837, 10.1002/adem.200310405

Ghali, 2004, General and localized corrosion of magnesium alloys: a critical review, J. Mater. Eng. Perform., 13, 7, 10.1361/10599490417533

Liu, 2009, Corrosion of magnesium and its alloys, Corros. Sci., 51, 1733, 10.1016/j.corsci.2009.04.025

Gu, 2010, Corrosion fatigue behaviors of two biomedical Mg alloys–AZ91D and WE43–in simulated body fluid, Acta Biomater., 6, 4605, 10.1016/j.actbio.2010.07.026

Bundy, 1991, Stress-enhanced ion release—the effect of static loading, Biomaterials, 12, 627, 10.1016/0142-9612(91)90108-M

Bundy, 1986, The influence of static stress on the corrosion behavior of 316L stainless steel in Ringer's solution, J. Biomed. Mater. Res., 20, 493, 10.1002/jbm.820200406

Zhang, 2010, Research on an Mg–Zn alloy as a degradable biomaterial, Acta Biomater., 6, 626, 10.1016/j.actbio.2009.06.028

Wang, 2011, Dynamic behaviors of a Ca–P coated AZ31B magnesium alloy during in vitro and in vivo degradations, Mater. Sci. Eng. B, 176, 1718, 10.1016/j.mseb.2011.06.005

Kannan, 2011, Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid, J. Biomed. Mater. Res. B Appl. Biomater., 96, 303, 10.1002/jbm.b.31766

Song, 1998, Corrosion behaviour of AZ21, AZ501 and AZ91 in sodium chloride, Corros. Sci., 40, 1769, 10.1016/S0010-938X(98)00078-X

Lee, 2000, The role of solute in grain refinement of magnesium, Metall. Mater. Trans. A, 31, 2895, 10.1007/BF02830349

Ding, 2014, Effects of alloying elements on the corrosion behavior and biocompatibility of biodegradable magnesium alloys: a review, J. Mater. Chem. B, 2, 1912, 10.1039/C3TB21746A

Song, 2011, Corrosion behaviour of bulk ultra-fine grained AZ91D magnesium alloy fabricated by equal-channel angular pressing, Corros. Sci., 53, 362, 10.1016/j.corsci.2010.09.044

Song, 1999, Corrosion mechanisms of magnesium alloys, Adv. Eng. Mater., 1, 11, 10.1002/(SICI)1527-2648(199909)1:1<11::AID-ADEM11>3.0.CO;2-N

Li, 2010, Biodegradable Mg-Ca and Mg-Ca-Y alloys for regenerative medicine, Materials Science Forum, Trans. Tech. Publ., 654, 2192

Kim, 2011, Effect of calcium addition on the corrosion behavior of Mg–5Al alloy, Intermetallics, 19, 1831, 10.1016/j.intermet.2011.07.024

Yin, 2008, Effect of Zn on mechanical property and corrosion property of extruded Mg-Zn-Mn alloy, Trans. Nonferrous Metals Soc. China, 18, 763, 10.1016/S1003-6326(08)60131-4

Song, 2012, The effect of Zn concentration on the corrosion behavior of Mg–xZn alloys, Corros. Sci., 65, 322, 10.1016/j.corsci.2012.08.037

Witte, 2008, Degradable biomaterials based on magnesium corrosion, Curr. Opinion Solid State Mater. Sci., 12, 63, 10.1016/j.cossms.2009.04.001

Song, 2009, Corrosion characterization of Mg–8Li alloy in NaCl solution, Corros. Sci., 51, 1087, 10.1016/j.corsci.2009.03.011

Zeng, 2014, Corrosion and characterisation of dual phase Mg–Li–Ca alloy in Hank's solution: the influence of microstructural features, Corros. Sci., 79, 69, 10.1016/j.corsci.2013.10.028

Hort, 2010, Magnesium alloys as implant materials–principles of property design for Mg–RE alloys, Acta Biomater., 6, 1714, 10.1016/j.actbio.2009.09.010

Rokhlin, 2003

Luo, 2010, Microstructure and mechanical properties of extruded magnesium-aluminum-cerium alloy tubes, Metall. Mater. Trans. A, 41, 2662, 10.1007/s11661-010-0278-3

Witte, 2007, Biodegradable magnesium scaffolds: part 1: appropriate inflammatory response, J. Biomed. Mater. Res. A, 81, 748, 10.1002/jbm.a.31170

Witte, 2007, Biodegradable magnesium scaffolds: part II: peri-implant bone remodeling, J. Biomed. Mater. Res. A, 81, 757, 10.1002/jbm.a.31293

Feyerabend, 2010, Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines, Acta Biomater., 6, 1834, 10.1016/j.actbio.2009.09.024

Sun, 1997, Effects of metal ions on osteoblast-like cell metabolism and differentiation, J. Biomed. Mater. Res., 34, 29, 10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P

Raggatt, 2010, Cellular and molecular mechanisms of bone remodeling, J. Biol. Chem., 285, 25103, 10.1074/jbc.R109.041087

Wang, 2009, Sol–gel coatings on metals for corrosion protection, Prog. Org. Coat., 64, 327, 10.1016/j.porgcoat.2008.08.010

Wright, 2000

Reetz, 1997, Entrapment of biocatalysts in hydrophobic sol-gel materials for use in organic chemistry, Adv. Mater., 9, 943, 10.1002/adma.19970091203

Brinker, 2013

Hench, 1998

Hu, 2012, Recent progress in corrosion protection of magnesium alloys by organic coatings, Prog. Org. Coat., 73, 129, 10.1016/j.porgcoat.2011.10.011

Gaur, 2014, In vitro investigation of biodegradable polymeric coating for corrosion resistance of Mg-6Zn-Ca alloy in simulated body fluid, Mater. Sci. Eng. C, 42, 91, 10.1016/j.msec.2014.05.035

Khramov, 2006, Sol–gel coatings with phosphonate functionalities for surface modification of magnesium alloys, Thin Solid Films, 514, 174, 10.1016/j.tsf.2006.02.023

Shi, 2009, Improvement of corrosion resistance of pure magnesium in Hanks' solution by microarc oxidation with sol–gel TiO2 sealing, J. Alloys Compd., 469, 286, 10.1016/j.jallcom.2008.01.102

Lalk, 2010, Biocompatibility and degradation behaviour of degradable magnesium sponges coated with bioglass–method establishment within the framework of a pilot study, Mater. Werkst., 41, 1025, 10.1002/mawe.201000704

Ishizaki, 2011, Corrosion resistance and durability of superhydrophobic surface formed on magnesium alloy coated with nanostructured cerium oxide film and fluoroalkylsilane molecules in corrosive NaCl aqueous solution, Langmuir, 27, 4780, 10.1021/la2002783

Agrawal, 1998, Reconstructing the human body using biomaterials, J. Miner. Met. Mater. Soc., 50, 31, 10.1007/s11837-998-0064-5

Middleton, 2000, Synthetic biodegradable polymers as orthopedic devices, Biomaterials, 21, 2335, 10.1016/S0142-9612(00)00101-0

Zhao, 2008, Study of PLGA coating on bio-absorbable Mg alloy [J], J. Funct. Mater., 6, 030

Miller, 1977, Degradation rates of oral resorbable implants (polylactates and polyglycolates): rate modification with changes in PLA/PGA copolymer ratios, J. Biomed. Mater. Res., 11, 711, 10.1002/jbm.820110507

Nair, 2007, Biodegradable polymers as biomaterials, Prog. Polym. Sci., 32, 762, 10.1016/j.progpolymsci.2007.05.017

Takahashi, 2005, Enhanced osteoinduction by controlled release of bone morphogenetic protein-2 from biodegradable sponge composed of gelatin and β-tricalcium phosphate, Biomaterials, 26, 4856, 10.1016/j.biomaterials.2005.01.012

Saito, 2005, Synthetic biodegradable polymers as drug delivery systems for bone morphogenetic proteins, Adv. Drug Deliv. Rev., 57, 1037, 10.1016/j.addr.2004.12.016

Shi, 2015, Preparation and characterization of PLA coating and PLA/MAO composite coatings on AZ31 magnesium alloy for improvement of corrosion resistance, Surf. Coat. Technol., 262, 26, 10.1016/j.surfcoat.2014.11.069

Zeng, 2014, In vitro degradation of MAO/PLA coating on Mg-1.21 Li-1.12 Ca-1.0 Y alloy, Front. Mater. Sci., 8, 343, 10.1007/s11706-014-0264-6

Chen, 2011, Interaction between a high purity magnesium surface and PCL and PLA coatings during dynamic degradation, Biomed. Mater., 6, 025005, 10.1088/1748-6041/6/2/025005

Alabbasi, 2012, Polylactic acid coating on a biodegradable magnesium alloy: an in vitro degradation study by electrochemical impedance spectroscopy, Thin Solid Films, 520, 6841, 10.1016/j.tsf.2012.07.090

Wu, 2008, Improvement of mechanical and biological properties of porous CaSiO3 scaffolds by poly (d, l-lactic acid) modification, Acta Biomater., 4, 343, 10.1016/j.actbio.2007.08.010

Rezwan, 2006, Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering, Biomaterials, 27, 3413, 10.1016/j.biomaterials.2006.01.039

Leja, 2010, Polymer biodegradation and biodegradable polymers—a review, Pol. J. Environ. Stud., 19, 255

Reed, 1981, Biodegradable polymers for use in surgery-poly (glycolic)/poly (Iactic acid) homo and copolymers: 2. In vitro degradation, Polymer, 22, 494, 10.1016/0032-3861(81)90168-3

Ostrowski, 2013, Biodegradable poly (lactide-co-glycolide) coatings on magnesium alloys for orthopedic applications, J. Mater. Sci. Mater. Med., 24, 85, 10.1007/s10856-012-4773-5

Chen, 2014, Electrosprayed PLGA smart containers for active anti-corrosion coating on magnesium alloy AMlite, J. Mater. Chem. A, 2, 5738, 10.1039/c3ta14999d

Li, 2010, In vitro degradation and cell attachment of a PLGA coated biodegradable Mg–6Zn based alloy, J. Mater. Sci., 45, 6038, 10.1007/s10853-010-4688-9

Park, 2013, Polycaprolactone coating with varying thicknesses for controlled corrosion of magnesium, J. Coat. Technol. Res., 10, 695, 10.1007/s11998-013-9474-6

Li, 2014, Deposition of microarc oxidation–polycaprolactone duplex coating to improve the corrosion resistance of magnesium for biodegradable implants, Thin Solid Films, 562, 561, 10.1016/j.tsf.2014.04.004

Degner, 2013, Electrochemical investigations of magnesium in DMEM with biodegradable polycaprolactone coating as corrosion barrier, Appl. Surf. Sci., 282, 264, 10.1016/j.apsusc.2013.05.115

Cai, 2011, Fabrication of anticorrosive multilayer onto magnesium alloy substrates via spin-assisted layer-by-layer technique, Mater. Sci. Eng. C, 31, 1800, 10.1016/j.msec.2011.08.012

Sell, 2010, The use of natural polymers in tissue engineering: a focus on electrospun extracellular matrix analogues, Polymers, 2, 522, 10.3390/polym2040522

Tan, 2010, Injectable, biodegradable hydrogels for tissue engineering applications, Materials, 3, 1746, 10.3390/ma3031746

Bose, 2012, Recent advances in bone tissue engineering scaffolds, Trends Biotechnol., 30, 546, 10.1016/j.tibtech.2012.07.005

Mushahary, 2014, Collagen type-I leads to in vivo matrix mineralization and secondary stabilization of Mg–Zr–Ca alloy implants, Colloids Surf. B Biointerfaces, 122, 719, 10.1016/j.colsurfb.2014.08.005

Wang, 2013, Poly (L-lactic acid)/hydroxyapatite/collagen composite coatings on AZ31 magnesium alloy for biomedical application, Proc. Inst. Mech. Eng. H J. Eng. Med., 227, 1094, 10.1177/0954411913493845

Fekry, 2014, Electrochemical impedance spectroscopy of chitosan coated magnesium alloys in a synthetic sweat medium, Surf. Coat. Technol., 238, 126, 10.1016/j.surfcoat.2013.10.058

Gu, 2009, Surface modification of an Mg-1Ca alloy to slow down its biocorrosion by chitosan, Biomed. Mater., 4, 1, 10.1088/1748-6041/4/4/044109

Bai, 2012, Fabrication of chitosan/magnesium phosphate composite coating and the in vitro degradation properties of coated magnesium alloy, Mater. Lett., 73, 59, 10.1016/j.matlet.2011.12.102

Liu, 2012, Improved anticorrosion of magnesium alloy via layer-by-layer self-assembly technique combined with micro-arc oxidation, Mater. Lett., 75, 118, 10.1016/j.matlet.2012.02.016

Vilker, 1981, The osmotic pressure of concentrated protein solutions: effect of concentration and pH in saline solutions of bovine serum albumin, J. Colloid Interface Sci., 79, 548, 10.1016/0021-9797(81)90106-5

Rahimnejad, 2006, Production of biological nanoparticles from bovine serum albumin for drug delivery, Afr. J. Biotechnol., 5, 1918

Liu, 2007, Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin, J. Mater. Res., 22, 1806, 10.1557/jmr.2007.0241

Killian, 2010, Functionalization of metallic magnesium with protein layers via linker molecules, Langmuir, 26, 12044, 10.1021/la101880r

Luo, 2011, Electrochemical deposition of conducting polymer coatings on magnesium surfaces in ionic liquid, Acta Biomater., 7, 441, 10.1016/j.actbio.2010.09.006

B. Klocke, U. Bayer, Implant and method for production of the same, U.S. Patent 8,709,073 2014.

Wei, 2014, A universal approach to crosslinked hierarchical polymer multilayers as stable and highly effective antifouling coatings, Adv. Mater., 26, 2688, 10.1002/adma.201304737

Garinot, 2007, PEGylated PLGA-based nanoparticles targeting M cells for oral vaccination, J. Control. Release, 120, 195, 10.1016/j.jconrel.2007.04.021

Rho, 1998, Mechanical properties and the hierarchical structure of bone, Med. Eng. Phys., 20, 92, 10.1016/S1350-4533(98)00007-1

Kubota, 1999, Review processing and mechanical properties of fine-grained magnesium alloys, J. Mater. Sci., 34, 2255, 10.1023/A:1004561205627

Deschamps, 1998, Influence of predeformation on ageing in an Al-Zn-Mg alloy-I. Microstructure evolution and mechanical properties, Acta Biomater., 47, 281, 10.1016/S1359-6454(98)00293-6

Rzychoń, 2007, Microstructure of WE43 casting magnesium alloys, J. Achiev. Mater. Manuf. Eng., 21, 31

Hermawan, 2010, Degradable metallic biomaterials: design and development of Fe-Mn alloys for stents, J. Biomed. Mater. Res. A, 93, 1, 10.1002/jbm.a.32224

Michalik, 2013, The effect of modification with rare earth elements on ZnAl22Cu3 alloy structure and mechanical properties/Wpływ Modyfikacji Pierwiastkami Ziem Rzadkich Na Strukture I Własciwosci Mechaniczne Stopu ZnAl22Cu3, Arch. Metall. Mater., 58, 49, 10.2478/v10172-012-0149-6

Menthe, 2000, Improvement of the mechanical properties of austenitic stainless steel after plasma nitriding, Surf. Coat. Technol., 133, 259, 10.1016/S0257-8972(00)00930-0

Niinomi, 1998, Mechanical properties of biomedical titanium alloys, Mater. Sci. Eng. A, 243, 231, 10.1016/S0921-5093(97)00806-X

Brantley, 1993, Cobalt-chromium and nickel-chromium alloys for removable prosthodontics, part 1: mechanical properties, J. Prosthodont., 2, 144, 10.1111/j.1532-849X.1993.tb00398.x

Munz, 2013

Fratzl, 1998, Fibrillar structure and mechanical properties of collagen, J. Struct. Biol., 122, 119, 10.1006/jsbi.1998.3966

Leung, 2008, Comparison of morphology and mechanical properties of PLGA bioscaffolds, Biomed. Mater., 3, 025006, 10.1088/1748-6041/3/2/025006

Kurniawan, 2011, Elastic properties of polycaprolactone at small strains are significantly affected by strain rate and temperature, Proc. Inst. Mech. Eng. H J. Eng. Med., 225, 1015, 10.1177/0954411911413059

Perego, 1996, Effect of molecular weight and crystallinity on poly (lactic acid) mechanical properties, J. Appl. Polym. Sci., 59, 37, 10.1002/(SICI)1097-4628(19960103)59:1<37::AID-APP6>3.0.CO;2-N

Walker, 2012, Magnesium alloys: predicting in vivo corrosion with in vitro immersion testing, J. Biomed. Mater. Res. B Appl. Biomater., 100, 1134, 10.1002/jbm.b.32680

Chaya, 2015, In vivo study of magnesium plate and screw degradation and bone fracture healing, Acta Biomater., 18, 262, 10.1016/j.actbio.2015.02.010

Abidin, 2013, The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ91, Corros. Sci., 75, 354, 10.1016/j.corsci.2013.06.019

Wang, 2008, Corrosion process of pure magnesium in simulated body fluid, Mater. Lett., 62, 2181, 10.1016/j.matlet.2007.11.045

Kirkland, 2012, Assessing the corrosion of biodegradable magnesium implants: a critical review of current methodologies and their limitations, Acta Biomater., 8, 925, 10.1016/j.actbio.2011.11.014

Abidin, 2011, Corrosion of high purity Mg, AZ91, ZE41 and Mg2Zn0·2Mn in Hank's solution at room temperature, Corros. Sci., 53, 862, 10.1016/j.corsci.2010.10.008

Wen, 2009, Corrosion behaviors of Mg and its alloys with different Al contents in a modified simulated body fluid, J. Alloys Compd., 488, 392, 10.1016/j.jallcom.2009.08.147

Witte, 2006, In vitro and in vivo corrosion measurements of magnesium alloys, Biomaterials, 27, 1013, 10.1016/j.biomaterials.2005.07.037

Xue, 2012, In vivo and in vitro degradation behavior of magnesium alloys as biomaterials, J. Mater. Sci. Technol., 28, 261, 10.1016/S1005-0302(12)60051-6

Sanchez, 2015, Mg and Mg alloys: how comparable are in vitro and in vivo corrosion rates? A review, Acta Biomater., 13, 16, 10.1016/j.actbio.2014.11.048

Ullmann, 2013, Influence of the grain size on the in vivo degradation behaviour of the magnesium alloy LAE442, Proc. Inst. Mech. Eng. H J. Eng. Med., 227, 317, 10.1177/0954411912471495

Mueller, 2010, Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications, Acta Biomater., 6, 1749, 10.1016/j.actbio.2009.12.048

Thomann, 2009, Comparison of the resorbable magnesium. Alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone-implant-contact after 12months implantation duration in a rabbit model, Mater. Werkst., 40, 82, 10.1002/mawe.200800412

Krause, 2010, Degradation behaviour and mechanical properties of magnesium implants in rabbit tibiae, J. Mater. Sci., 45, 624, 10.1007/s10853-009-3936-3

Wlake, 2011, Plasticity and corrosion resistance of magnesium alloy WE43, Arch. Mater. Sci. Eng., 51, 16

Liu, 2014, Influence of fine-grain and solid-solution strengthening on mechanical properties and in vitro degradation of WE43 alloy, Biomed. Mater., 9, 015014, 10.1088/1748-6041/9/1/015014

Zeng, 2016, In vitro corrosion and cytocompatibility of a microarc oxidation coating and poly (l-lactic acid) composite coating on Mg-1Li-1Ca alloy for orthopedic implants, ACS Appl. Mater. Inter., 8, 10014, 10.1021/acsami.6b00527

Ostrowski, 2013, Corrosion protection and improved cytocompatibility of biodegradable polymeric layer-by-layer coatings on AZ31 magnesium alloys, Acta Biomater., 9, 8704, 10.1016/j.actbio.2013.05.010

Zhang, 2012, Fabrication of hydroxyapatite/stearic acid composite coating and corrosion behavior of coated magnesium alloy, Mater. Lett., 88, 76, 10.1016/j.matlet.2012.08.011

Park, 2013, Effect on corrosion behavior of collagen film/fiber coated AZ31 magnesium alloy, Dig. J. Nanomater. Biostruct., 8, 1227

Lévesque, 2008, Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials, Acta Biomater., 4, 284, 10.1016/j.actbio.2007.09.012