Basic principles of respiratory function monitoring in ventilated newborns: A review
Tài liệu tham khảo
Mahmoud, 2011, Current methods of non-invasive ventilatory support for neonates, Paediatr Respir Rev, 12, 196, 10.1016/j.prrv.2010.12.001
Fischer, 2013, Avoiding endotracheal ventilation to prevent bronchopulmonary dysplasia: a meta-analysis, Pediatrics, 132, e1351, 10.1542/peds.2013-1880
Walsh, 2005, Extremely low birthweight neonates with protracted ventilation: mortality and 18-month neurodevelopmental outcomes, J Pediatr, 146, 798, 10.1016/j.jpeds.2005.01.047
Hummler, 2009, New and alternative modes of mechanical ventilation in neonates, Semin Fetal Neonatal Med, 14, 42, 10.1016/j.siny.2008.08.006
Mahmoud, 2011, Modern mechanical ventilation strategies in newborns: a review, Technol Health Care, 19, 307, 10.3233/THC-2011-0633
Brown, 2011, Mechanical ventilation of the premature neonate, Respir Care, 56, 1298, 10.4187/respcare.01429
Bhutani, 2002, Clinical applications of pulmonary function and graphics, Semin Neonatol, 7, 391, 10.1053/siny.2002.0133
Reiterer, 2015, Evaluation of bedside pulmonary function in the neonate: From the past to the future, Pediatr Pulmonol, 50, 1039, 10.1002/ppul.23245
Becker, 2007, Real-time pulmonary graphic monitoring, Clin Perinatol, 34, 1, 10.1016/j.clp.2006.12.002
Schmalisch, 2011, Neonatal monitoring, 80
Schibler, 2002, Positive end-expiratory pressure and ventilation inhomogeneity in mechanically ventilated children, Pediatr Crit Care Med, 3, 124, 10.1097/00130478-200204000-00006
Proquitte, 2010, The effect of surgery on lung volume and conventional monitoring parameters in ventilated newborn infants, Eur Respir J, 35, 1072, 10.1183/09031936.00058009
Wilson, 1982, Algorithms for the detection of breaths from respiratory waveform recordings of infants, Med Biol Eng Comput, 20, 286, 10.1007/BF02442794
Schmidt, 1998, Comparative investigations of algorithms for the detection of breaths in newborns with disturbed respiratory signals, Comput Biomed Res, 31, 413, 10.1006/cbmr.1998.1493
Govindarajan, 1990, Breath detection algorithm in digital computers, Int J Clin Monit Comput, 7, 59, 10.1007/BF02915533
Schmalisch, 2001, In vitro assessment of equipment and software to assess tidal breathing parameters in infants, Eur Respir J, 17, 100, 10.1183/09031936.01.17101000
Nikischin, 1996, Patient-triggered ventilation: a comparison of tidal volume and chestwall and abdominal motion as trigger signals, Pediatr Pulmonol, 22, 28, 10.1002/(SICI)1099-0496(199607)22:1<28::AID-PPUL5>3.0.CO;2-G
Hummler, 1996, Patient-triggered ventilation in neonates: comparison of a flow-and an impedance-triggered system, Am J Respir Crit Care Med, 154, 1049, 10.1164/ajrccm.154.4.8887606
la Cruz, 2005, Intratracheal pressure: a more accurate reflection of pulmonary airway pressure in pediatric patients with respiratory failure, Pediatr Crit Care Med, 6, 175, 10.1097/01.PCC.0000154957.45432.F5
Guttmann, 2000, Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes, Crit Care Med, 28, 1018, 10.1097/00003246-200004000-00018
Keszler, 2005, Volume-targeted ventilation, J Perinatol, 25, S19, 10.1038/sj.jp.7211313
Nassabeh-Montazami, 2009, The impact of instrumental dead-space in volume-targeted ventilation of the extremely low birth weight (ELBW) infant, Pediatr Pulmonol, 44, 128, 10.1002/ppul.20954
Roske, 1998, Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices, J Clin Monit Comput, 14, 413, 10.1023/A:1009993916980
Cannon, 2000, Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube, Am J Respir Crit Care Med, 162, 2109, 10.1164/ajrccm.162.6.9906112
Ruttimann, 1981, Measurement of tracheal airflow in newborns by a differential flow system, Crit Care Med, 9, 801, 10.1097/00003246-198111000-00011
Foitzik, 2001, Deadspace free ventilatory measurements in newborns during mechanical ventilation, Crit Care Med, 29, 413, 10.1097/00003246-200102000-00036
Donaldsson, 2015, Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing, PLoS One, 10, e0133432, 10.1371/journal.pone.0133432
Kolobow, 2004, Ultrathin-wall, two-stage, twin endotracheal tube: a tracheal tube with minimal resistance and minimal dead space for use in newborn and infant patients, Pediatr Crit Care Med, 5, 379, 10.1097/01.PCC.0000128602.22489.2D
Parravicini, 2007, A comparison of a new, ultrathin-walled two-stage twin endotracheal tube and a conventional endotracheal tube in very premature infants with respiratory distress syndrome: a pilot study, Am J Perinatol, 24, 117, 10.1055/s-2007-970082
Proquitte, 2014, Dead space reduction by Kolobow's endotracheal tube does not justify the waiving of volume monitoring in small, ventilated lungs, J Clin Monit Comput, 28, 605, 10.1007/s10877-014-9559-5
Olsson, 1970, Transthoracic impedance, with special reference to newborn infants and the ratio air-to-fluid in the lungs, Acta Paediatr Scand, Suppl 207, 7
Kurth, 2011, Continuous non-invasive monitoring of tidal volumes by measurement of tidal impedance in neonatal piglets, PLoS One, 6, e21003, 10.1371/journal.pone.0021003
Frerichs, 2006, Lung volume recruitment after surfactant administration modifies spatial distribution of ventilation, Am J Respir Crit Care Med, 174, 772, 10.1164/rccm.200512-1942OC
Frerichs, 2001, Non-invasive radiation-free monitoring of regional lung ventilation in critically ill infants, Intensive Care Med, 27, 1385, 10.1007/s001340101021
Stick, 1992, Validation of respiratory inductance plethysmography (“Respitrace”) for the measurement of tidal breathing parameters in newborns, Pediatr Pulmonol, 14, 187, 10.1002/ppul.1950140308
Adams, 1993, Tidal volume measurements in newborns using respiratory inductive plethysmography, Am Rev Respir Dis, 148, 585, 10.1164/ajrccm/148.3.585
Brooks, 1997, Collaborative Home Infant Monitoring Evaluation, Pediatr Pulmonol, 23, 429, 10.1002/(SICI)1099-0496(199706)23:6<429::AID-PPUL6>3.0.CO;2-D
Robles-Rubio, 2015, Automated analysis of respiratory behavior in extremely preterm infants and extubation readiness, Pediatr Pulmonol, 50, 479, 10.1002/ppul.23151
Brown, 1998, Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants, Eur Respir J, 12, 935, 10.1183/09031936.98.12040935
Poole, 2000, Respiratory inductance plethysmography in healthy infants: a comparison of three calibration methods, Eur Respir J, 16, 1084, 10.1034/j.1399-3003.2000.16f11.x
Bar-Yishay, 2003, Automated, real-time calibration of the respiratory inductance plethysmograph and its application in newborn infants, Physiol Meas, 24, 149, 10.1088/0967-3334/24/1/311
Emeriaud, 2008, Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions, Pediatr Pulmonol, 43, 1135, 10.1002/ppul.20923
Pickerd, 2013, Electromagnetic inductance plethysmography to measure tidal breathing in preterm and term infants, Pediatr Pulmonol, 48, 160, 10.1002/ppul.22584
Pickerd, 2014, Tidal breathing in preterm infants receiving and weaning from continuous positive airway pressure, J Pediatr, 164, 1058, 10.1016/j.jpeds.2013.12.049
Sherman, 1989, Decreased incidence of subglottic stenosis using an “appropriate-sized” endotracheal tube in neonates, Pediatr Pulmonol, 6, 183, 10.1002/ppul.1950060311
Contencin, 1993, Size of endotracheal tube and neonatal acquired subglottic stenosis. Study Group for Neonatology and Pediatric Emergencies in the Parisian Area, Arch Otolaryngol Head Neck Surg, 119, 815, 10.1001/archotol.1993.01880200015002
Mahmoud, 2011, Tracheal tube airleak in clinical practice and impact on tidal volume measurement in ventilated neonates, Pediatr Crit Care Med, 12, 197, 10.1097/PCC.0b013e3181e89834
Bernstein, 1995, Airway leak size in neonates and autocycling of three flow-triggered ventilators, Crit Care Med, 23, 1739, 10.1097/00003246-199510000-00020
Foitzik, 1998, Leak measurements in spontaneously breathing premature newborns by using the flow-through technique- Special Communication, J Appl Physiol, 85, 1187, 10.1152/jappl.1998.85.3.1187
Schmalisch, 2009, Comparison of different techniques to measure air leaks during CPAP treatment in neonates, Med Eng Phys, 31, 124, 10.1016/j.medengphy.2008.05.002
Mahmoud, 2009, Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators, Acta Paediatr, 98, 1116, 10.1111/j.1651-2227.2009.01319.x
Main, 2001, The influence of endotracheal tube leak on the assessment of respiratory function in ventilated children, Intensive Care Med, 27, 1788, 10.1007/s001340101105
Bhutani, 1988, Evaluation of neonatal pulmonary mechanics and energetics: a two factor least mean square analysis, Pediatr Pulmonol, 4, 150, 10.1002/ppul.1950040306
Davis, 1997, Measurement of infant pulmonary mechanics: comparative analysis of techniques, Pediatr Pulmonol, 23, 105
Schmalisch, 2005, Inertance measurements by jet pulses in ventilated small lungs after perfluorochemical liquid (PFC) applications, Physiol Meas, 26, 239, 10.1088/0967-3334/26/3/009
Neve, 2000, Ventilator-induced overdistension in children: dynamic versus low-flow inflation volume-pressure curves, Am J Respir Crit Care Med, 162, 139, 10.1164/ajrccm.162.1.9906091
Mahmoud, 2012, Effect of endotracheal tube leakage on respiratory function monitoring: Comparison of three neonatal ventilators, J Pediatr Intensive Care, 2, 61
Dimitriou, 1996, Early measurement of lung volume--a useful discriminator of neonatal respiratory failure severity, Physiol Meas, 17, 37, 10.1088/0967-3334/17/1/004
Vilstrup, 1992, Functional residual capacity and ventilation homogeneity in mechanically ventilated small neonates, J Appl Physiol, 73, 276, 10.1152/jappl.1992.73.1.276
Proquitte, 2006, Functional residual capacity measurement by heptafluoropropane in ventilated newborn lungs: in vitro and in vivo validation, Crit Care Med, 34, 1789, 10.1097/01.CCM.0000220065.93507.AB
Habib, 1991, Moment analysis of a multibreath nitrogen washout based on an alveolar gas dilution number, Am Rev Respir Dis, 144, 513, 10.1164/ajrccm/144.3_Pt_1.513
Pillow, 2006, Lung function tests in neonates and infants with chronic lung disease: global and regional ventilation inhomogeneity, Pediatr Pulmonol, 41, 105, 10.1002/ppul.20319
Schmalisch, 2006, The effect of changing ventilator settings on indices of ventilation inhomogeneity in small ventilated lungs, BMC Pulm Med, 6, 20, 10.1186/1471-2466-6-20
Schmalisch, 2015, The lung clearance index in young infants: impact of tidal volume and dead space, Physiol Meas, 36, 1601, 10.1088/0967-3334/36/7/1601
Gravenstein, 2011
Schmalisch, 2004, Time and volumetric capnography in the neonate, 81
Wenzel, 1999, Comparison of different methods for dead space measurements in ventilated newborns using CO2-volume plot, Intensive Care Med, 25, 705, 10.1007/s001340050933
Proquitte, 2004, Current limitations of volumetric capnography in surfactant-depleted small lungs, Pediatr Crit Care Med, 5, 75, 10.1097/01.PCC.0000102384.60676.E5
Nuckton, 2002, Pulmonary dead-space fraction as a risk factor for death in the acute respiratory distress syndrome, N Engl J Med, 346, 1281, 10.1056/NEJMoa012835
Raurich, 2010, Prognostic value of the pulmonary dead-space fraction during the early and intermediate phases of acute respiratory distress syndrome, Respir Care, 55, 282
Schmalisch, 2012, Effect of endotracheal tube leak on capnographic measurements in a ventilated neonatal lung model, Physiol Meas, 33, 1, 10.1088/0967-3334/33/10/1631