Avaliação dos resultados de componente femoral cônico de fixação proximal não cimentado em fêmur tipo C de Dorr

Revista Brasileira de Ortopedia - Tập 49 - Trang 260-266 - 2014
Munif Ahmad Hatem1, Bernardo Ferreira da Luz1, Rodrigo Nishimoto Nishi1, Paulo Gilberto Cimbalista de Alencar1
1Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR, Brasil

Tài liệu tham khảo

Lachiewicz, 2008, Cement fixation of the femoral component in older patients, Instr Course Lect, 57, 261 Dorr, 1993, Structural and cellular assessment of bone quality of proximal femur, Bone, 14, 231, 10.1016/8756-3282(93)90146-2 Hagio, 2003, Embolic events during total hip arthroplasty an echocardiographic study, J Arthroplasty, 18, 186, 10.1054/arth.2003.50027 Harris, 1969, Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end‐result study using a new method of result evaluation, J Bone Joint Surg Am, 51, 737, 10.2106/00004623-196951040-00012 Engh, 1990, Roentgenographic assessment of biological fixation of porous surfaced femoral components, Clin Orthop Relat Res, 107 Keisu, 2001, Primary cementless total hip arthroplasty in octogenarians, J Bone Joint Surg Am, 83, 359, 10.2106/00004623-200103000-00007 Kobayashi, 1997, Early radiological observations may predict the long term survival of femoral hip prosthesis, J Bone Joint Surg Br, 79, 583, 10.1302/0301-620X.79B4.7210 Gruen, 1979, Modes of failure of cemented stem type femoral component: a radiographic analysis of loosening, Clin Orthop Relat Res, 17 Ostendorf, 2002, The epidemiology of total hip replacement in the Netherlands and Sweden: present status and future needs, Acta Orthop Scand, 73, 282, 10.1080/000164702320155257 Berend, 2004, Cementless double‐tapered total hip arthroplasty in patients 75 years of age and older, J Arthroplasty, 19, 288, 10.1016/j.arth.2003.11.002 Reitman, 2003, Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type c bone, J Arthroplasty, 18, 116, 10.1016/S0883-5403(03)00344-9 Kelly, 2007, Use of a hydroxyapatite‐coated stem in patients with Dorr Type C femoral bone, Clin Orthop Relat Res, 112, 10.1097/BLO.0b013e318156bf96 Badhe, 2002, The uncemented bi‐contact total hip arthroplasty, J Arthroplasty, 17, 896, 10.1054/arth.2002.34523 Eingartner, 2006, Long‐term results of an uncemented straight femoral shaft prosthesis, Hip Int, 16, 23, 10.1177/112070000601600104 Mulliken, 1996, Hip arthroplasty radiographic evaluation and stability a tapered titanium femoral stem inserted without cement in a total hip arthroplasty radiographic evaluation and stability, J Bone Joint Surg Am, 78, 1214, 10.2106/00004623-199608000-00012 McLaughlin, 1997, Total hip arthroplasty with an uncemented femoral component. Excellent results at ten‐year follow‐up, J Bone Joint Surg Br, 79, 900, 10.1302/0301-620X.79B6.7482 Keisu, 2001, The uncemented fully textured Lord hip prosthesis: a 10‐ to 15‐year followup study, Clin Orthop Relat Res, 133, 10.1097/00003086-200101000-00020