Automatic detection of distorted plethysmogram pulses in neonates and paediatric patients using an adaptive-network-based fuzzy inference system

Artificial Intelligence in Medicine - Tập 24 Số 2 - Trang 149-165 - 2002
Suliman Belal1, Azzam Taktak2, Alan Nevill2, Stephen A. Spencer3, David Roden3, Sharon Bevan3
1Department of Biomedical Engineering and Medical Physics, Centre for Science and Technology in Medicine, University of Keele, Thornburrow Drive, Hartshill, Stoke On Trent, Staffordshire ST4 7QB, U ...#TAB#
2Clinical Technology Department, North Staffordshire Hospitals (NHS) Trust, City General, Newcastle Road, Stoke On Trent, Staffordshire ST4 6QG, UK#TAB#
3Women and Children's Division, Maternity Unit, Newcastle Road, Stoke On Trent, Staffordshire ST4 6QG, UK#TAB#

Tóm tắt

Từ khóa


Tài liệu tham khảo

Adams, 1995, A computer algorithm for differentiating valid from distorted pulse oximeter waveforms in neonates, Paediatr. Pulmonol., 19, 307, 10.1002/ppul.1950190510

Araki S, Nomura H, Hayashi L, Wakami N. Self generating method of fuzzy inference rules. In: Proceedings of the International Fuzzy Engineering Symposium. IFES’92 (Ohmsha, Japan). Ohmsha, Japan: IOS Press, 1992. p. 1047–58.

Belal, 2001, A fuzzy system for detecting distorted plethysmogram pulses in neonates and paediatric patients, Physiol. Measure., 22, 397, 10.1088/0967-3334/22/2/311

Berenji, 1992, Learning and tuning fuzzy logic controllers through reinforcements, IEEE Trans. Neural Networks, 3, 724, 10.1109/72.159061

Cunningham, 1997, Comparison of nurse and computer charting of physiological variables in an intensive care unit, Int. J. Clin. Monit. Comput., 13, 235, 10.1023/A:1016967407632

Durand, 1986, Pulse oximetry for continuous oxygen monitoring in sick newborn infants, J. Paediatr., 109, 1052, 10.1016/S0022-3476(86)80298-0

Fanconi, 1985, Pulse oximetry in paediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension, J. Paediatr., 107, 362, 10.1016/S0022-3476(85)80507-2

Grieve, 1997, Comparison of two different pulse oximeters in monitoring preterm infants, Crit. Care Med., 25, 2051, 10.1097/00003246-199712000-00025

Halgamuge, 1994, Neural networks in designing fuzzy systems for real world applications, Fuzzy Sets Syst., 65, 1, 10.1016/0165-0114(94)90242-9

Hanley, 1982, The meaning and use of the area under a receiver operating characteristic (ROC) curve, Radiology, 143, 29, 10.1148/radiology.143.1.7063747

Hudson DL, Cohen ME. In: Akay M, editor. Neural networks and artificial intelligence for biomedical engineering. New York: IEEE Press, 2000.

Ichikawa R, Nishimura K, Kunugi M, Shimada K. Auto-tuning method of fuzzy membership functions using neural network learning algorithm. In: Proceedings of the 2nd International Conference on Fuzzy Logic and Neural Networks. IIZUKA’92 (Iizuka, Japan). Iizuka, Japan: Fuzzy Logic Systems Institute Press, 1992. p. 345–8.

Jang R. Fuzzy controller design without domain experts. In: Proceedings of the IEEE International Conference on Fuzzy Systems. FUZZ-IEEE (San Diego, CA). Piscataway, NJ: IEEE Press, 1992. p. 289–96.

Jang, 1992, Self-learning fuzzy controllers based on temporal back propagation, IEEE Trans. Neural Networks, 3, 714, 10.1109/72.159060

Jang, 1993, ANFIS: adaptive-network-based fuzzy inference system, IEEE Trans. Syst. Man Cybernetics, 23, 665, 10.1109/21.256541

Karr, 1991, Applying genetics to fuzzy logic, AI Expert, 6, 26

Katayama R, Kajitani Y, Nishida Y. A self generating and tuning method for fuzzy modelling using interior penalty method. In: Proceedings of the 2nd International Conference on Fuzzy Logic and Neural Networks (IIZUKA’92, Iizuka, Japan). Iizuka, Japan: Fuzzy Logic Systems Institute Press, 1992. p. 349–52.

Koeck, 1995, Pulse oximetry in ventilated preterm newborns: reliability of detection of hyperoxaemia and hypoaxaemia, and feasibility of alarm settings, Acta Paediatr., 84, 613, 10.1111/j.1651-2227.1995.tb13709.x

Lafontine, 1996, Pulse oximetry: accuracy of methods of interpreting graphic summaries, Paediatr. Pulmonol., 21, 121, 10.1002/(SICI)1099-0496(199602)21:2<121::AID-PPUL7>3.0.CO;2-U

Lamb JF, Ingram CG, Johnston IA, Pitman RM. Essentials of physiology. Oxford: Blackwell Scientific, 1991.

Lee, 1996, Fuzzy inference neural network for fuzzy model tuning, Cybernetics, 26, 637

Makivirta, 1991, The median filter as a processor for patient monitor limit alarm system in intensive care, Comput. Meth. Programs Biomed., 34, 139, 10.1016/0169-2607(91)90039-V

Metz, 1999, “Proper” binomial ROC curves: theory and maximum-likelihood estimation, J. Math. Psychol., 43, 1, 10.1006/jmps.1998.1218

Michael A, Takagi H. Integrating design stages of fuzzy systems using genetic algorithms. In: Proceedings of the 2nd IEEE International Conference on Fuzzy Systems. FUZZ-IEEE’93 (San Francisco, CA). Piscataway, NJ: IEEE Press, 1993. p. 612–7.

Nauck, 1999, Obtaining interpretable fuzzy classification rules from medical data, Artif. Intell. Med., 16, 149, 10.1016/S0933-3657(98)00070-0

Nomura H, Hayashi L, Wakami N. A self-tuning method of fuzzy reasoning by genetic algorithm, In: Proceedings of the International Fuzzy Systems and Intelligent Control Conference. IFSICC’92 (Louisville, KY). Louisville, KY: Institution for Fuzzy Systems and Intelligent Control Press, 1992. p. 236–45.

Poets, 1994, Non-invasive monitoring of oxygen in infants and children: practical considerations and area of concern, Paediatrics, 93, 737, 10.1542/peds.93.5.737

Poets, 1997, Detection of movement artifact in recorded pulse oximeter saturation, Eur. J. Paediatr., 156, 808, 10.1007/s004310050719

Rheineck-Leyssius, 1998, Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxaemia, J. Clin. Monit. Comput., 14, 151, 10.1023/A:1007431305610

Sinex, 1999, Pulse oximetry: principles and limitations, Am. J. Emergency Med., 17, 59, 10.1016/S0735-6757(99)90019-0

Takagi, 1991, NN-driven fuzzy reasoning, Int. J. Approx. Reason., 5, 191, 10.1016/0888-613X(91)90008-A

Thilo, 1993, Saturation by pulse oximetry: comparison of the results obtained by instruments of different brands, J. Paediatr., 122, 620, 10.1016/S0022-3476(05)83549-8

Tsien, 1997, Poor prognosis for existing monitors in the intensive care unit, Crit. Care Med., 25, 614, 10.1097/00003246-199704000-00010

Usher, 1999, A fuzzy logic-controlled classifier for use in implantable cardioverter defibrillators, Pacing Clin. Electrophysiol., 22, 183, 10.1111/j.1540-8159.1999.tb00329.x

Virant-Klun, 1999, Fuzzy logic alternative for analysis in biomedical sciences, Comput. Biomed. Res., 32, 305, 10.1006/cbmr.1999.1517

Vuorimaa, 1994, Fuzzy self-organising map, Fuzzy Sets Syst., 66, 223, 10.1016/0165-0114(94)90312-3

Wolf, 1996, Improved monitoring of preterm infants by fuzzy logic, Technol. Health Care, 4, 193, 10.3233/THC-1996-4207