Auditory displays in anesthesiology

Current Opinion in Anaesthesiology - Tập 22 Số 6 - Trang 788-795 - 2009
Penelope Sanderson1,2,3, David Liu4, Simon Jenkins5
1e-mail: [email protected]
2fax: +61 7 3365 4466
3to Professor Penelope Sanderson, PhD, FASSA, School of Information Technology and Electrical Engineering (ITEE), The University of Queensland, St Lucia, QLD 4072, Australia Tel: +61 7 330 8620
4School of Information Technology and Electrical Engineering (ITEE), The University of Queensland, Brisbane, Australia
5Centre for Sleep Research, University of South Australia, Adelaide, Australia; Department of Anaesthesia, Pain Medicine and Hyperbaric Medicine, Royal Adelaide Hospital, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Sanderson, 2006, The multimodal world of medical monitoring displays, Appl Ergonomics, 37, 501, 10.1016/j.apergo.2006.04.022

Watson, 2007, Designing for attention with sound: challenges and extensions to ecological interface design, Hum Factors, 49, 331, 10.1518/001872007X312531

Sarter, 2006, Multimodal information presentation: design guidance and research challenges, Int J Indus Ergonomics, 36, 439, 10.1016/j.ergon.2006.01.007

Woods, 1995, The alarm problem and directed attention in dynamic fault management, Ergonomics, 38, 2371, 10.1080/00140139508925274

Kramer, 1994, An introduction to auditory display

Morris, 2005, How well can anaesthetists discriminate pulse oximeter tones?, Anaesth Intens Care, 33, 497, 10.1177/0310057X0503300412

Candra, 2006, Audio spectrum and sound pressure levels vary between pulse oximeters, Can J Anaesth, 53, 26, 10.1007/BF03021524

Yamanaka, 2008, The sound intensity and characteristics of variable-pitch pulse oximeters., J Clin Monitor Comput, 22, 199, 10.1007/s10877-008-9125-0

Loeb, 2002, A laboratory evaluation of an auditory display designed to enhance intraoperative monitoring, Anesth Analg, 94, 362, 10.1213/00000539-200202000-00025

Watson, 2004, Sonification helps eyes-free respiratory monitoring and task timesharing, Hum Factors, 46, 497, 10.1518/hfes.46.3.497.50401

Brewster, 1992, A detailed investigation into the effectiveness of earcons, 471

McGookin, 2004, Understanding concurrent earcons: applying auditory scene analysis principles to concurrent earcon recognition, ACM Trans Appl Percept, 1, 130, 10.1145/1024083.1024087

Block, 2008, ‘For if the trumpet give an uncertain sound, who shall prepare himself to the battle?’ (I Corinthians 14: 8, KJV), Anesth Analg, 106, 357, 10.1213/ane.0b013e3181606927

Wee, 2008, Are melodic medical equipment alarms easily learned?, Anesth Analg, 106, 501, 10.1213/01.ane.0000286148.58823.6c

Williams, 2005, Measuring the performance of audible alarms for anaesthesia, Physiol Meas, 26, 571, 10.1088/0967-3334/26/4/020

Block, 2000, A proposed new set of alarm sounds which satisfy standards and rationale to encode source information, J Clin Monitor Comput, 16, 541, 10.1023/A:1011471607530

Blattner, 1989, Earcons and icons: their structure and common design principles, Hum Comp Interact, 4, 11, 10.1207/s15327051hci0401_1

Stanton, 2006, Speech-based alarm displays, 1257

Merry, 2001, A new, safety-oriented, integrated drug administration and automated anesthesia record system, Anesth Analg, 93, 385, 10.1213/00000539-200108000-00030

Kanagachandran, 2007, Pilot study: designing medical alarm sounds for semantic association and ease of learning, Internet J Anesthesiol, 12, 60601

Hagenouw, 2007, Should we be alarmed by our alarms?, Curr Opin Anaesthesiol, 20, 590, 10.1097/ACO.0b013e3282f10dff

Lacherez, 2007, Overlapping medical alarms are almost indiscriminable, Hum Factors, 49, 637, 10.1518/001872007X215719

McNeer, 2007, A new paradigm for the design of audible alarms that convey urgency information, J Clin Monitor Comput, 21, 353, 10.1007/s10877-007-9096-6

Watson, 2004, Tailoring reveals information requirements: the case of anaesthesia alarms, Interact Comput, 16, 271, 10.1016/j.intcom.2003.12.002

Santamore, 2004, The sounds of saturation, J Clin Monitor Comput, 18, 89, 10.1023/B:JOCM.0000032698.47717.06

Fitch, 1994, Sonifying the body electric: superiority of an auditory over a visual display in a complex, multivariate system

Sanderson, 2008, Advanced auditory displays and head-mounted displays: advantages and disadvantages for monitoring by the distracted anesthesiologist, Anesth Analg, 106, 1787, 10.1213/ane.0b013e31817325cb

Baier, 2007, Event-based sonification of EEG rhythms in real time, Clin Neurophysiol, 118, 1377, 10.1016/j.clinph.2007.01.025

Barrass, 2006, Listening to the mind listening: an analysis of sonification reviews, designs and correspondences, Leonardo Music J, 16, 13, 10.1162/lmj.2006.16.13

Alapetite, 2008, Speech recognition for the anaesthesia record during crisis scenarios, Int J Med Inform, 77, 448, 10.1016/j.ijmedinf.2007.08.007

Alapetite, 2008, Impact of noise and other factors on speech recognition in anaesthesia, Int J Med Inform, 77, 68, 10.1016/j.ijmedinf.2006.11.007

Charbonnier, 2007, A trend-based alarm system to improve patient monitoring in intensive care units, Control Eng Pract, 15, 1039, 10.1016/j.conengprac.2006.12.005

Gorges, 2009, Improving alarm performance in the medical intensive care unit using delays and clinical context, Anesth Analg, 108, 1546, 10.1213/ane.0b013e31819bdfbb

Dosani, 2009, Clinical evaluation of algorithms for context-sensitive physiological monitoring in children, Br J Anaesth, 102, 686, 10.1093/bja/aep045

Ansermino, 2009, An evaluation of a novel software tool for detecting changes in physiological monitoring, Anesth Analg, 108, 873, 10.1213/ane.0b013e318193ff87

Ford, 2008, A novel vibrotactile display to improve the performance of anesthesiologists in a simulated critical incident, Anesth Analg, 106, 1182, 10.1213/ane.0b013e318163f7c2

Ng, 2005, An evaluation of a vibro-tactile display prototype for physiological monitoring, Anesth Analg, 101, 1719, 10.1213/01.ANE.0000184121.03150.62

Imhoff, 2006, Alarm algorithms in critical care monitoring, Anesth Analg, 102, 1525, 10.1213/01.ane.0000204385.01983.61

Imhoff, 2009, Smart alarms from medical devices in the OR and ICU, Best Pract Res Clin Anaesth, 23, 39, 10.1016/j.bpa.2008.07.008

Imhoff, 2009, The crying wolf: still crying?, Anesth Analg, 108, 1382, 10.1213/ane.0b013e31819ed484

Thompson, 2008, Multisensory integration with a head-mounted display: sound delivery and self-motion, Hum Factors, 50, 789, 10.1518/001872008X312323

Furnham, 2002, Music is as distracting as noise: the differential distraction of background music and noise on the cognitive performance of introverts and extraverts, Ergonomics, 45, 203, 10.1080/00140130210121932

Sanderson, 2005, Effects of ambient music on simulated anaesthesia monitoring with visual and auditory displays, Anaesthesia, 60, 1073, 10.1111/j.1365-2044.2005.04377.x

Sanderson, 2006, Learnability and discriminability of melodic medical equipment alarms, Anaesthesia, 61, 142, 10.1111/j.1365-2044.2005.04502.x

Bennett, 1992, Graphical displays: implications for divided attention, focused attention, and problem-solving, Hum Factors, 34, 513, 10.1177/001872089203400502

Reising, 2002, Ecological interface design for pasteurizer II: a process description of semantic mapping, Hum Factors, 44, 222, 10.1518/0018720024497952

Anderson, 2009, Sonification design for complex work domains: dimensions and distractors, J Exp Psychol Appl, 15, 183, 10.1037/a0016329

Walker, 2007, Consistency of magnitude estimations with conceptual data dimensions used for sonification, Appl Cog Psychol, 21, 579, 10.1002/acp.1291

Walsh, 2005, Establishing scales of perceived severity for clinical situations during anaesthesia, Physiol Meas, 95, 339

Seagull, 2001, Anesthesia alarms in context: an observational study, Hum Factors, 43, 66, 10.1518/001872001775992453

Bliss, 1995, Human probability matching behaviour in response to alarms of varying reliability, Ergonomics, 38, 2300, 10.1080/00140139508925269

Ryherd, 2008, Characterising noise and perceived work environment in a neurological intensive care unit, J Acoust Soc Am, 123, 747, 10.1121/1.2822661

Sesay, 2009, Audibility of anaesthesia alarms during magnetic resonance imaging: should we be alarmed?, Eur J Anaesthesiol, 26, 117, 10.1097/EJA.0b013e328320a95e

Tsiou, 2008, Noise in the operating rooms of Greek hospitals, J Acoust Soc Am, 123, 747, 10.1121/1.2821972