Attenuation Scale Calibration of an Optical Time Domain Reflectometer Using an External Laser Source

MAPAN - 2018
Osama Terra1, Hatem Hussein1
1National Institute of Standards (NIS), Giza, Egypt

Tóm tắt

Optical time domain reflectometers (OTDRs) are widely used to measure the attenuation of optical fibers. Accurate measurement of the attenuation requires periodic calibration of OTDRs. In this paper, a system is proposed based on the external source method (ESM) to calibrate of the attenuation scale of an OTDR over a dynamic range of around 15 dB. The ESM method has several advantages over the widely-used standard reference fiber (SRF) since it is fast, can be automated and offers direct traceability to the SI units. In order to estimate the accuracy of the proposed setup, an OTDR has been calibrated using the SRF and the ESM methods. The calibration uncertainty of the ESM method is found to be 0.040 dB, which is similar to that of the SRF method which is found to be 0.038 dB.

Từ khóa


Tài liệu tham khảo

B. Danielson, Optical time-domain reflectometer specifications and performance testing, Appl. Opt., 24 (1985), 2313–2322.

O. Terra, Distance scale calibration of optical time domain reflectometer using active intensity modulation, MAPAN, 6 (2014).

O. Terra and H. Hussein, Accurate fiber length measurement using time-of-flight technique, J. Opt. Commun., 37 (2015), 187–191.

L. Robertsson, M. Zucco, L-S. Ma, O. Terra, F. Saraiva, S. Gentil, C. Chekirda, Yu Zakharenko, V. Fedorin and L. Mostert, Results from the CI-2004 campaign at the BIPM of the BIPM.L-K11 ongoing key comparison, Metrologia 42 (2005).

O. Terra and H. Hussein, An ultra-stable optical frequency standard for telecommunication purposes based upon the 5S1/2 → 5D5/2 two-photon transition in Rubidium, Appl. Phys. B, 122 (2016), 27.

M. Medhat, M. Sobee, H. M. Hussein, and O. Terra, Distance measurement using frequency scanning interferometry with mode-hoped laser, Opt. Laser Technol., 80 (2016), 209–213.

European Standard, Calibration of optical time-domain reflectometers (OTDR), EN 61746 (2005).

W. Rutzen, W. Stöcklein, C. Unger, Calibration of optical time domain reflectometers, Opt. Commun., 127 (1996), 343–352.

Calibration of Optical Time-Domain Reflectometers (OTDR’s),TIA/EIA-455-266, Telecommunications Industry Association, Arlington, VA (2002).

IEEE Standard on Transitions, Pulses, and Related Waveforms, IEEE Standard 181–2003, The Institute of Electrical and Electronic Engineers, Piscataway, NJ, USA (2003).

O.Celikel, M. Kücükoglu, M. Durak, and F. Samadov, Determination of attenuation coefficients of single mode optical fiber standards to be used in OTDR calibrations, Opt. Laser Technol. 37 (2005), 420–426.

BIPM, IEC, ISO. Guide to the expression of uncertainty in measurement. ISBN 92-67-10188-9 (1995).