Assessment of the performance of hysteretic energy dissipation bracing systems
Tóm tắt
The advantages of passive supplemental dampers for performance enhancement of new and existing structures have been demonstrated extensively in the past. The big amount of experimental tests carried out all over the world on framed structures upgraded by energy dissipating bracing (EDB) systems based on hysteretic dampers (HDs), have shown their effectiveness in reducing seismic effects on buildings. The mechanical characteristics of the HDs in some cases may be different from those arising by the design procedure due to industrial tolerance or because of some damage suffered during previous earthquakes. In order to assess the robustness of this technique, in terms of capacity of seismic vibrations control even for significant changes in the mechanical characteristics of the EDB system respect to the design ones, in this paper experimental tests and parametric nonlinear time history analysis have been carried out changing the characteristics of the HD stiffness and strength. The experimental results refer to the shaking table tests performed at the Structural Laboratory of the University of Basilicata within a wide research program, named Joint Experimental Testing on Passive and semiActive Control Systems. The program has been completely funded by the Italian Department of Civil Protection within the activity of the Research Line 7 of the ReLUIS (Italian Network of University Laboratories of Earthquake Engineering) 2005–2008 project. A displacement-focused design procedure has been considered to evaluate the mechanical characteristics of the dissipating system, with the aim of limiting inter-storey drifts after frame yielding. From the experimental point of view, two design solutions have been tested for chevron braces equipped with HD, assuming the same stiffness but different values of both ductility demand and yield strength of the HDs. Moreover, parametric studies have been performed through numerical simulations. This paper provides an overview of the experimental set up and briefly summarizes the experimental outcomes and the comparison with the results of numerical nonlinear time history analysis. Moreover, the results of the parametric analysis for the assessment of the performances of the dissipating system in controlling structural response are presented.
Tài liệu tham khảo
15th WCEE (2012) Proceedings of the 15th world congress on earthquake engineering, Lisboa, Portugal
ANSYS (2010) Academic Mechanical Research, Ansys Italia srl
Antonacci E, De Stefano A, Gattulli V, Lepidi M, Matta E (2011) Comparative study of vibration-based parametric identification techniques for a three-dimensional frame structure. Published online on Structural Control and Health Monitoring, Wiley Online Library, doi:10.1002/stc.449
ATC-17-1 (1993) Proceedings of seminar on seismic isolation, passive energy dissipation and active control. Applied Technology Council Redwood City, CA
Bouc R (1967) Forced vibration of mechanical systems with hysteresis. In: Proceedings of the 4th international conference on nonlinear oscillation, Prague (Czechoslovakia)
CEN (2004) EN 1998-1. Design of structures for earthquake resistance—Part 1: general rules, seismic actions and rules for buildings. Bruxelles
CEN (2009) UNI EN 15129:2009. Anti-seismic devices, Bruxelles
Christopoulos C, Filiatrault A (2007) Principles of passive supplemental damping and seismic isolation. IUSS Press, Istituto Universitario di Studi Superiori di Pavia, Italy
Ciampi V (1989) Un sistema di controventi dissipative per strutture antisismiche in acciaio. In: International meeting on base isolation and passive energy dissipation, Assisi (Italy), pp 17.01–17.16
Ciampi V (1993) Development of passive energy dissipation techniques for buildings. In: International post-SMIRT conference seminar on seismic isolation, energy dissipation and control of vibrations of structures, pp 495–510
Constantinou MC, Soong TT, Dargush GF (2001) Passive energy dissipation systems for structural design and retrofit. Monograph series no.1, MCEER, State University of New York at Buffalo, NY
CSI (2012) SAP2000: static and dynamic finite element analysis of structures. Computers and Structures, Inc., Berkeley
Di Cesare A, Ponzo FC, Auletta G, Gilio A (2011) Behaviour factor of concrete structures with hysteretic energy dissipating bracing system. In: Proceedings of the XIV ANIDIS L’Ingegneria Sismica in Italia, Bari (Italy)
Di Cesare A, Ponzo FC, Nigro D, Dolce M, Moroni C (2012) Experimental and numerical behavior of hysteretic and visco-re-centring energy dissipating bracing systems. Bull Earthq Eng. doi:10.1007/s10518-012-9363-x
Dolce M, Cardone D, Ponzo FC (2001) Comparison of different passive control systems for r/c frames through shaking table tests. In: Proceedings of the 5th world congress on joints, bearings and seismic systems for concrete structures, Rome, Italy
Dolce M, Cardone D, Ponzo FC, Valente C (2005) Shaking table tests on reinforced concrete frames without and with passive control systems. J Earthq Eng Struct Dyn 34(14):1687–1717
Dolce M, Ponzo FC, Di Cesare A, Ditommaso R, Moroni C, Nigro D, Serino G, Sorace S, Gattulli V, Occhiuzzi A, Vulcano A, Foti D (2008) JET-PACS project: joint experimental testing on passive and semiactive control systems. In: Proceedings of the 14th world conference on earthquake engineering, Beijing, China, paper No. 183
ESD (2008) European Commission for Community Research. European Strong Motion Database (on-line). http://www.isesd.cv.ic.ac.uk/ESD
Fajfar P (1999) Capacity spectrum method based on inelastic demand spectra. Earthq Eng Struct Dyn 28:979–993
FEMA356 (2000) Prestandard and commentary for the seismic rehabilitation of buildings. Federal Emergency Management Agency and American society of civil engineering, Washington, USA
FEMA450 (2003) NEHRP recommended provisions for seismic regulations for new buildings and other structures. Building Seismic Safety Council National Institute of Building Sciences, Washington, DC, USA
Kam WY, Pampanin S, Palermo A, Carr AJ (2010) Self-centering structural systems with combination of hysteretic and viscous energy dissipations. Earthq Eng Struct Dyn 39:1083–1108. doi:10.1002/eqe.983
Kelly JM, Skinner RI, Heine AJ (1972) Mechanisms of energy absorption in special device for use in earthquake resistant structures. Bull NZ Soc Earthq Eng 5(3):63–88
Marriott D, Pampanin S, Palermo A (2009) Quasi-static and pseudo-dynamic testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters. Earthq Eng Struct Dyn 38:331–354. doi:10.1002/eqe.857
Martìnez-Rueda JE (2002) On the evolution of energy dissipation devices for seismic design. Earthq Spectra 18(2):309–346
Mazza F, Vulcano A (2013) Nonlinear seismic analysis to evaluate the effectiveness of damped braces designed for retrofitting r.c. framed structures. Int J Mech 7:251–261
Nims DK, Richter PJ, Bachman RE (1993) The use of the energy dissipating restraint for seismic Hazard mitigation. Earthq Spectra 9(3):467–489
NTC (2008) Italian technical code for constructions (in Italian). DM 14/01/2008, Ministry of Infrastructures, Italy
Ponzo FC, Di Cesare A (2009) Numerical and experimental assessment of the robustness of a seismic upgrading technique for framed buildings based on hysteretic dissipating devices. In: Proceedings of the 11th world conference on seismic isolation, energy dissipation and active vibration control of structures, Guangzhou, China
Ponzo FC, Di Cesare A, Nigro D, Vulcano A, Mazza F, Dolce M, Moroni C (2012) Jet-pacs project: dynamic experimental tests and numerical results obtained for a steel frame equipped with hysteretic damped braces. J Earthq Eng 16:662–685. ISSN: 1363-2469 print/1559-808X. doi:10.1080/13632469.2012.657335
Priestley MJN, Calvi GM, Kowalsky MJ (2007) Displacement-based seismic design of structures. IUSS Press, Pavia
Soong TT, Dargush GF (2007) Passive energy dissipation systems in structural engineering. Wiley, ISBN-13:9780471968214
Sorace S, Terenzi G (2008) Seismic protection of frame structures by fluid viscous damped braces. ASCE J Struct Eng 134:45–55
Sorace S, Terenzi G, Fadi F (2012) Shaking table and numerical seismic performance evaluation of a fluid viscous-dissipative bracing system. Earthq Spectra 28:1619–1642
Tsai KC, Chen HW, Hong CP, Su YF (1993) Design of steel triangular plate energy absorbers for seismic-resistant construction. Earthq Spectra 9(3):505–528
Wen YK (1976) Method of random vibration of hysteretic systems. J Eng Mech 102:249–263
Whittaker AS, Bertero VV, Thompson CL, Alonso LJ (1991) Seismic testing of steel plate energy dissipation devices. Earthq Spectra 7(4):563–604