Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

Zeitschrift für Medizinische Physik - Tập 27 - Trang 218-231 - 2017
Verónica García-Vázquez1, Eugenio Marinetto1, Pedro Guerra2,3, Manlio Fabio Valdivieso-Casique4, Felipe Ángel Calvo1,5,6, Eduardo Alvarado-Vásquez1,7, Claudio Vicente Sole8,1, Kirby Gannett Vosburgh9, Manuel Desco10,1,11, Javier Pascau10,1,11
1Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
2Departamento de Ingeniería Electrónica, ETSI Telecomunicación, Universidad Politécnica de Madrid, Madrid, Spain
3Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
4GMV SA, Madrid, Spain
5Departamento de Oncología, Hospital General Universitario Gregorio Marañón, Madrid, Spain
6Facultad de Medicina Universidad Complutense de Madrid, Madrid, Spain
7Servicio de Oncología Radioterápica, Hospital General Universitario Gregorio Marañón, Madrid, Spain
8Service of Radiation Oncology, Instituto de Radiomedicina, Santiago, Chile
9Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, USA
10Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid, Spain
11Centro de Investigación Biomédica en Red de Salud Mental, CIBERSAM, Madrid, Spain

Tài liệu tham khảo

Calvo, 2006, Intraoperative radiation therapy – First part: Rationale and techniques, Crit Rev Oncol Hematol, 59, 106, 10.1016/j.critrevonc.2005.11.004 Calvo, 2013, Research opportunities in intraoperative radiation therapy: the next decade 2013–2023, Clin Transl Oncol, 15, 683, 10.1007/s12094-013-1019-z Pascau, 2012, An innovative tool for intraoperative electron beam radiotherapy simulation and planning: description and initial evaluation by radiation oncologists, Int J Radiat Oncol Biol Phys, 83, e287, 10.1016/j.ijrobp.2011.12.063 Valdivieso-Casique, 2015, RADIANCE—a planning software for intra-operative radiation therapy, Transl Cancer Res, 4, 196 Santos, 2011, Initial clinical experience of pencil beam dose modelling for intraoperative electron radiation therapy (IOERT), Radiother Oncol, 99, S246 Guerra, 2014, Feasibility assessment of the interactive use of a Monte Carlo algorithm in treatment planning for intraoperative electron radiation therapy, Phys Med Biol, 59, 7159, 10.1088/0031-9155/59/23/7159 García-Vázquez, 2013, Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios, Phys Med Biol, 58, 8769, 10.1088/0031-9155/58/24/8769 Hanna, 2014, Intraoperative radiation therapy in early breast cancer using a linear accelerator outside of the operative suite: an “image-guided” approach, Int J Radiat Oncol Biol Phys, 89, 1015, 10.1016/j.ijrobp.2014.04.038 Roeder, 2010, Postplanning of a three-dimensional dose distribution for intraoperative electron radiation therapy (IOERT) using intraoperative C-arm based 3D-imaging – a phantom study, Int J CARS, 5, S71 Pascau, 2011, Intraoperative imaging in IOERT sarcoma treatment: initial experience in two clinical cases, Int J Radiat Oncol Biol Phys, 81, S90, 10.1016/j.ijrobp.2011.06.184 Costa, 2015, Assessment of clinically relevant dose distributions in pelvic IOERT using Gafchromic EBT3 films, Phys Med, 31, 692, 10.1016/j.ejmp.2015.05.013 Srinivasan, 2014, Applications of linac-mounted kilovoltage cone-beam computed tomography in modern radiation therapy: a review, Pol J Radiol, 79, 181, 10.12659/PJR.890745 Richter, 2008, Investigation of the usability of conebeam CT data sets for dose calculation, Radiat Oncol, 3, 42, 10.1186/1748-717X-3-42 van Zijtvetd, 2007, Correction of conebeam CT values using a planning CT for derivation of the “dose of the day”, Radiother Oncol, 85, 195, 10.1016/j.radonc.2007.08.010 Fotina, 2012, Feasibility of CBCT-based dose calculation: comparative analysis of HU adjustment techniques, Radiother Oncol, 104, 249, 10.1016/j.radonc.2012.06.007 Zhu, 2009, Scatter correction for cone-beam CT in radiation therapy, Med Phys, 36, 2258, 10.1118/1.3130047 Lecchi, 2008, Current concepts on imaging in radiotherapy, Eur J Nucl Med Mol Imag, 35, 821, 10.1007/s00259-007-0631-y Mutic, 2003, Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM radiation therapy committee task group no. 66, Med Phys, 30, 2762, 10.1118/1.1609271 Constantinou, 1992, An electron-density calibration phantom for CT-based treatment planning computers, Med Phys, 19, 325, 10.1118/1.596862 Verhaegen, 2005, Sensitivity study for CT image use in Monte Carlo treatment planning, Phys Med Biol, 50, 937, 10.1088/0031-9155/50/5/016 Schneider, 2000, Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions, Phys Med Biol, 45, 459, 10.1088/0031-9155/45/2/314 Salvat, 2011, PENELOPE, a code system for Monte Carlo simulation of electron and photon transport Calama Santiago, 2011, Pencil beam for electron intraoperative radiotherapy. Results of dose calculations in heterogeneous media, Radiother Oncol, 99, S13, 10.1016/S0167-8140(11)70148-7 Low, 1998, A technique for the quantitative evaluation of dose distributions, Med Phys, 25, 656, 10.1118/1.598248 Ezzell, 2009, IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119, Med Phys, 36, 5359, 10.1118/1.3238104 Nobah, 2011, Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy, J Appl Clin Med Phys, 12, 80, 10.1120/jacmp.v12i3.3432 De Vos, 2009, Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature, Int J Oral Maxillofac Surg, 38, 609, 10.1016/j.ijom.2009.02.028 Strobel, 2009, 33 Mah, 2010, Deriving hounsfield units using grey levels in cone beam computed tomography, Dentomaxillofac Radiol, 39, 323, 10.1259/dmfr/19603304 Oliveira, 2013, Influence of anatomical location on CT numbers in cone beam computed tomography, Oral Surg Oral Med Oral Pathol Oral Radiol, 115, 558, 10.1016/j.oooo.2013.01.021 Hatton, 2009, Cone beam computerized tomography: the effect of calibration of the hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy, Phys Med Biol, 54, N329, 10.1088/0031-9155/54/15/N01 Ahn, 2015, Improvement of dose calculation accuracy on kV CBCT images with corrected electron density to CT number curve, J Radiat Prot Res, 40, 17, 10.14407/jrp.2015.40.1.017 Elstrøm, 2014, The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region – a phantom study, Acta Oncol, 53, 1114, 10.3109/0284186X.2014.927073 Jaju, 2013, Artefacts in cone beam CT, Open J Stomatol, 3, 292, 10.4236/ojst.2013.35049 Parsa, 2013, Influence of cone beam CT scanning parameters on grey value measurements at an implant site, Dentomaxillofac Radiol, 42, 79884780, 10.1259/dmfr/79884780 Rong, 2010, Dose calculation on kV cone beam CT images: an investigation of the HU-density conversion stability and dose accuracy using the site-specific calibration, Med Dosim, 35, 195, 10.1016/j.meddos.2009.06.001 Takemura, 2015, Long-term stability of the Hounsfield unit to electron density calibration curve in cone-beam computed tomography images for adaptive radiotherapy treatment planning, J Radiother Pract, 14, 410, 10.1017/S1460396915000321 Yadav, 2011, Feasibility study on effect and stability of adaptive radiotherapy on kilovoltage cone beam CT, Radiol Oncol, 45, 220, 10.2478/v10019-011-0024-5