Application of ozone gas for decontamination of nucleoside anticancer drugs

Ayumi Tsukamoto1,2, Shunji Ishiwata1, Asami Kajimoto1, Ryusuke Murata1, Rika Kitano1, Tomomi Inoue1, Takeshi Kotake1
1Division of Medical Pharmaceutics & Therapeutics, Faculty of Pharmacy, Kindai University, Higashi-Osaka, Japan
2Department of Pharmacy, Sakai City Medical Center, Sakai City, Japan

Tóm tắt

Exposure to anticancer drugs is hazardous and may lead to chromosomal abnormalities and spontaneous abortion in healthcare workers. Guidelines recommend surface decontamination and cleaning in order to minimize the occupational exposure to anticancer drugs, although no single process has been found to deactivate all currently available hazardous drugs. Ozone gas is oxidative and a decontaminant for bacteria; its characteristic as a gas has advantages in that it does not need to be wiped off or neutralized after use. The nucleoside anticancer drugs, cytarabine and fluorouracil, were exposed to ozone gas on plates under controlled humidity. The levels of exposed ozone were evaluated using the concentration-time (CT) value, which is the mathematical product of ozone concentration and exposure time. The effects of exposure to ozone on levels of the anticancer drugs were determined by high-performance liquid chromatography (HPLC). The levels of cytarabine decreased with increasing CT value and were not detected beyond 40,000 CT. The decomposition levels of the anticancer drug by ozone were CT-dependent irrespective of the maximum concentration of ozone. Higher humidity in the range from 70 to 90 % accelerated the decomposition of cytarabine and fluorouracil, and neither of the drugs were detected at 90 % humidity after exposure to ozone gas. Ozone gas decomposed these nucleoside anticancer drugs. This is the first report of the applicability of ozone gas as a decontaminator for anticancer drugs.

Tài liệu tham khảo

National Institute for Occupational Safety and Health. NIOSH alert: preventing occupational exposure to antineoplastic and other hazardous drugs in health care settings. Washington: US Department of Health and Human Services, Public Health Service, Center for Disease Control and Prevention; 2004. Lawson CC, Rocheleau CM, Whelan EA, Lividoti Hibert EN, Grajewski B, Spiegelman D, et al. Occupational exposures among nurses and risk of spontaneous abortion. Am J Obstet Gynecol. 2012;206:327. Dranitsaris G, Johnston M, Poirier S, Schueller T, Milliken D, Green E, et al. Are health care providers who work with cancer drugs at an increased risk for toxic events? A systematic review and meta-analysis of the literature. J Oncol Pharm Pract. 2005;11:69–78. McDiarmid MA, Oliver MS, Roth TS, Rogers B, Escalante C. Chromosome 5 and 7 abnormalities in oncology personnel handling anticancer drugs. J Occup Environ Med. 2010;52:1028–34. American Society of Health-System Pharmacists. ASHP guidelines on handling hazardous drugs. Am J Health-Syst Pharm. 2006;63:1172–93. Davies A, Pottage T, Bennett A, Walker J. Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment. J Hosp Infect. 2011;77:199–203. Aydogan A, Gurol MD. Application of gaseous ozone for inactivation of bacillus subtilis spores. J Air Waste Manage Assoc. 2006;56:179–85. Mochizuki C, Fujikawa I, Tei G, Yoshida J. A comparison of cleaning solutions in the biological safety cabinet for preparation of anti-cancer agents. J Jpn Soc Hosp Pharm. 2008;44:601–4. Occupational Safety and Health Administration, United States of Labor: Ozone. https://www.osha.gov/dts/chemicalsampling/data/CH_259300.html. Accessed 2 Sep 2016. United States Environmental Protection Agency. Alternative disinfectants and oxidants guidance manual. 1999. p. 7.1–2.