Anterior segment characteristics in normal and keratoconus eyes evaluated with a combined Scheimpflug/Placido corneal imaging device

Journal of Current Ophthalmology - Tập 28 - Trang 106-111 - 2016
Masoud Safarzadeh1, Nader Nasiri2
1Department of Optometry, Tehran University of Medical Sciences, Tehran, Iran
2Department of Ophthalmology, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Tài liệu tham khảo

Pinero, 2012, Characterization of corneal structure in keratoconus, J Cataract Refract Surg, 38, 2167, 10.1016/j.jcrs.2012.10.022 Fontes, 2010, Corneal biomechanical metrics and anterior segment parameters in mild keratoconus, Ophthalmology, 117, 673, 10.1016/j.ophtha.2009.09.023 Rabinowitz, 1998, Keratoconus Surv Ophthalmol, 42, 297, 10.1016/S0039-6257(97)00119-7 Wilson, 1991, Corneal topography of keratoconus, Cornea, 10, 2, 10.1097/00003226-199101000-00002 Maeda, 1994, Automated keratoconus screening with corneal topography analysis, Invest Ophthalmol Vis Sci, 35, 2749 Rabinowitz, 1995, Videokeratographic indices to aid in screening for keratoconus, J Refract Surg, 11, 371, 10.3928/1081-597X-19950901-14 Smolek, 1997, Current keratoconus detection methods compared with a neural network approach, Invest Ophthalmol Vis Sci, 38, 2290 Rabinowitz, 1999, KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus, J Cataract Refract Surg, 25, 1327, 10.1016/S0886-3350(99)00195-9 Auffarth, 2000, Keratoconus evaluation using the Orbscan topography system, J Cataract Refract Surg, 26, 222, 10.1016/S0886-3350(99)00355-7 Pflugfelder, 2002, Corneal thickness indices discriminate between keratoconus and contact lens-induced corneal thinning, Ophthalmology, 109, 2336, 10.1016/S0161-6420(02)01276-9 Fam, 2006, Corneal elevation indices in normal and keratoconic eyes, J Cataract Refract Surg, 32, 1281, 10.1016/j.jcrs.2006.02.060 Schlegel, 2008, Comparison of and correlation between anterior and posterior corneal elevation maps in normal eyes and keratoconus-suspect eyes, J Cataract Refract Surg, 34, 789, 10.1016/j.jcrs.2007.12.036 Nilforoushan, 2008, Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and wavefront analysis, J Cataract Refract Surg, 34, 623, 10.1016/j.jcrs.2007.11.054 Maeda, 1995, Neural network classification of corneal topography. Preliminary demonstration, Invest Ophthalmol Vis Sci, 36, 1327 Schwiegerling, 1996, Keratoconus detection based on videokeratoscopic height data, Optom Vis Sci, 73, 721, 10.1097/00006324-199612000-00001 Langenbucher, 1999, Keratoconus screening with wave-front parameters based on topography height data, Klin Monbl Augenheilkd, 214, 217, 10.1055/s-2008-1034779 de Sanctis, 2008, Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus, Ophthalmology, 115, 1534, 10.1016/j.ophtha.2008.02.020 Tomidokoro, 2000, Changes in anterior and posterior corneal curvatures in keratoconus, Ophthalmology, 107, 1328, 10.1016/S0161-6420(00)00159-7 Bessho, 2006, Automated keratoconus detection using height data of anterior and posterior corneal surfaces, Jpn J Ophthalmol, 50, 409, 10.1007/s10384-006-0349-6 Ucakhan, 2011, Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes, J Cataract Refract Surg, 37, 1116, 10.1016/j.jcrs.2010.12.049 Ambrosio, 2006, Corneal thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus, J Cataract Refract Surg, 32, 1851, 10.1016/j.jcrs.2006.06.025 Piñero, 2010, Escaf Vergara M, Miranda M. Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus, J Cataract Refract Surg, 36, 814, 10.1016/j.jcrs.2009.11.012 Milla, 2011, Pachymetric measurements with a new Scheimpflug photography-based system: intraobserver repeatability and agreement with optical coherence tomography pachymetry, J Cataract Refract Surg, 37, 310, 10.1016/j.jcrs.2010.08.038 Alio, 2006, Corneal higher order aberrations: a method to grade keratoconus, J Refract Surg, 22, 539, 10.3928/1081-597X-20060601-05 Jafri, 2007, Higher order wavefront aberrations and topography in early and suspected keratoconus, J Refract Surg, 23, 774, 10.3928/1081-597X-20071001-06 Lim, 2007, Evaluation of higher order ocular aberrations in patients with keratoconus, J Refract Surg, 23, 825, 10.3928/1081-597X-20071001-13 Masoud, 2015, Repeatability and intrasession reproducibility obtained by the Sirius anterior segment analysis system, Eye Contact Lens, 41, 107, 10.1097/ICL.0000000000000074 Randleman, 2003, Risk factors and prognosis for corneal ectasia after LASIK, Ophthalmology, 110, 267, 10.1016/S0161-6420(02)01727-X Piñero, 2003, Pentacam posterior and anterior corneal aberrations in normal and keratoconic eyes, Clin Exp Optom, 92, 297, 10.1111/j.1444-0938.2009.00357.x Gobbe, 2005, Corneal wavefront aberration measurements to detect keratoconus patients, Cont Lens Anterior Eye, 28, 57, 10.1016/j.clae.2004.12.001 Accardo, 2002, Neural network-based system for early keratoconus detection from corneal topography, J Biomed Inform, 35, 151, 10.1016/S1532-0464(02)00513-0 Nasser, 2012, Repeatability of the Sirius imaging system and agreement with the Pentacam HR, J Refract Surg, 28, 493, 10.3928/1081597X-20120619-01 De la Parra-Colin, 2014, Barrientos-Gutierrez T. Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers, Int Ophthalmol, 34, 27, 10.1007/s10792-013-9780-0 Rao, 2002, Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery, Ophthalmology, 109, 1642, 10.1016/S0161-6420(02)01121-1 Edmonds, 2009, Comparison of anterior chamber depth of normal and keratoconus eyes using Scheimpflug photography, Eye Contact Lens, 35, 120, 10.1097/ICL.0b013e31819cf5a6 Abolbashari, 2013, Anterior segment characteristics of keratoconus eyes in a sample of Asian population, Cont Lens Anterior Eye, 36, 191, 10.1016/j.clae.2013.01.005 Mannion, 2011, Reduction in corneal volume with severity of keratoconus, Curr Eye Res, 36, 522, 10.3109/02713683.2011.553306 Emre, 2007, Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system, J Cataract Refract Surg, 33, 1708, 10.1016/j.jcrs.2007.06.020 Gordon-Shaag, 2012, Aberrations and topography in normal, keratoconus-suspect, and keratoconic eyes, Optom Vis Sci, 89, 411, 10.1097/OPX.0b013e318249d727