Analysis of Biomechanical Differences Between Condylar Constrained Knee and Rotating Hinged Implants: A Numerical Study

Journal of Arthroplasty - Tập 35 - Trang 278-284 - 2020
Lorenzo Andreani1, Silvia Pianigiani2, Edoardo Bori2, Michele Lisanti1, Bernardo Innocenti2
1Orthopaedic and Trauma Unit, University of Pisa, Pisa, Italy
2BEAMS Department (Bio Electro and Mechanical Systems), Université Libre de Bruxelles, Brussels, Belgium

Tài liệu tham khảo

Sharkey, 2002, Insall award paper: why are total knee arthroplasty failing today?, Clin Orthop Relat Res, 404, 7, 10.1097/00003086-200211000-00003 Sharkey, 2014, Why are total knee arthroplasties failing today—has anything changed after 10 years?, J Arthroplasty, 29, 1774, 10.1016/j.arth.2013.07.024 Indelli, 2015, Level of constraint in revision knee arthroplasty, Curr Rev Musculoskelet Med, 8, 390, 10.1007/s12178-015-9295-6 Kurtz, 2007, Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030, J Bone Joint Surg Am, 89, 780, 10.2106/JBJS.F.00222 Vasso, 2013, Constraint choice in revision knee arthroplasty, Int Orthop, 37, 1279, 10.1007/s00264-013-1929-y Malcolm, 2016, Outcomes of varus-valgus constrained versus rotating-hinge implants in total knee arthroplasty, Orthopedics, 39, e140, 10.3928/01477447-20151228-07 Hommel, 2017, Constraint choice in revision knee arthroplasty: study protocol of a randomised controlled trial assessing the effect of level of constraint on postoperative outcome, BMJ Open, 7, e012964, 10.1136/bmjopen-2016-012964 Das, 2017, Constraints in total knee arthroplasty: current status and review of literature, Int J Res Med Sci, 5, 374, 10.18203/2320-6012.ijrms20170132 Lettin, 1978, The Stanmore hinged knee arthroplasty, J Bone Joint Surg Br, 60, 327, 10.1302/0301-620X.60B3.681408 Deburge, 1976, Guepar hinge prosthesis: complications and results with two years’ follow-up, Clin Orthop Relat Res, 120, 47 Walker, 1982, The kinematic rotating hinge: biomechanics and clinical application, Orthop Clin North Am, 13, 187, 10.1016/S0030-5898(20)30276-5 McAuley, 2003, Constraint in total knee arthroplasty: when and what?, J Arthroplasty, 18, 51, 10.1054/arth.2003.50103 Jones, 2009, Total knee arthroplasty with modular rotating platform hinge, Orthopedics, 29, S80 Sculco, 2006, The role of constraint in total knee arthroplasty, J Arthroplasty, 21, 54, 10.1016/j.arth.2006.02.166 Morgan, 2005, Constraint in primary total knee arthroplasty, J Am Acad Orthop Surg, 13, 515, 10.5435/00124635-200512000-00004 Hwang, 2010, Revision total knee arthroplasty with a cemented posterior stabilized, condylar constrained or fully constrained prosthesis: a minimum 2-year follow-up analysis, Clin Orthop Surg, 2, 112, 10.4055/cios.2010.2.2.112 Kafidas, 2015, Long term outcome of total knee arthroplasty rotating hinge designs, 179 Draganich, 1999, The effects of the rotating-hinge total knee replacement on gait and stair stepping, J Arthroplasty, 14, 743, 10.1016/S0883-5403(99)90231-0 Gudnason, 2011, Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up, Arch Orthop Trauma Surg, 131, 1601, 10.1007/s00402-011-1330-5 Barrack, 2000, The use of a modular rotating hinge component in salvage revision total knee arthroplasty, J Arthroplasty, 15, 858, 10.1054/arth.2000.9056 Neumann, 2012, Follow-up of a modular rotating hinge knee system in salvage revision total knee arthroplasty, J Arthroplasty, 27, 814, 10.1016/j.arth.2011.08.015 Gehrke, 2014, The role of hinges in primary total knee replacement, Bone Joint J, 96-B, 93, 10.1302/0301-620X.96B11.34143 Joshi, 2008, Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?, J Arthroplasty, 23, 1204, 10.1016/j.arth.2007.10.016 Hossain, 2010, Midterm assessment of causes and results of revision total knee arthroplasty, Clin Orthop Relat Res, 468, 1221, 10.1007/s11999-009-1204-0 Wilke, 2016, Rotating hinge total knee arthroplasty RT-PLUS solution: a clinical and radiographic follow-up, J Orthopedics Rheumatol, 3, 4 Dall’Oca, 2017, Evolution of TKA design, Acta Biomed, 88, 17 Pianigiani, 2015, Investigation on the effects induced by TKA features on tibio-femoral mechanics part II: tibial insert designs, J Mech Med Biol, 2, 1540035, 10.1142/S0219519415400357 Pianigiani, 2015, Biomechanical analysis of the post-cam mechanism in a TKA: comparison between conventional and semi-constrained insert designs, Int Biomech, 2, 22, 10.1080/23335432.2015.1014849 Anderson, 2007, Constrained condylar knee without stem extensions for difficult primary total knee arthroplasty, J Knee Surg, 20, 195 Lachiewicz, 2011, Results of a second-generation constrained condylar prosthesis in primary total knee arthroplasty, J Arthroplasty, 26, 1228, 10.1016/j.arth.2011.05.010 Kim, 2009, Revision total knee arthroplasty with use of a constrained condylar knee prosthesis, J Bone Joint Surg Am, 91, 1440, 10.2106/JBJS.H.00425 Arnout, 2015, Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs, Knee Surg Sports Traumatol Arthrosc, 23, 3343, 10.1007/s00167-014-3167-2 Fuchs, 2004, Quality of life and clinical outcome in salvage revision total knee replacement: hinged vs total condylar design, Knee Surg Sports Traumatol Arthrosc, 12, 140, 10.1007/s00167-003-0401-8 Walker, 2001, Comparison between a constrained condylar and a rotating hinge in revision knee surgery, Knee, 8, 269, 10.1016/S0968-0160(01)00121-1 Pianigiani, 2015, The use of finite element modeling to improve biomechanical research on knee prosthesis Innocenti, 2014, Load sharing and ligament strains in balanced, overstuffed and understuffed UKA. A validated finite element analysis, J Arthroplasty, 29, 1491, 10.1016/j.arth.2014.01.020 Brihault, 2016, All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty, Knee Surg Sports Traumatol Arthrosc, 24, 2550, 10.1007/s00167-015-3630-8 Innocenti, 2009, Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study, J Orthop Surg Res, 4, 26, 10.1186/1749-799X-4-26 Innocenti, 2016, Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or tibial component alignment?, J Arthroplasty, 31, 295, 10.1016/j.arth.2015.07.038 El-Zayat, 2016, Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study, Arch Orthop Trauma Surg, 136, 1741, 10.1007/s00402-016-2571-0 Barrack, 1999, Pain at the end of the stem after revision total knee arthroplasty, Clin Orthop Relat Res, 367, 216, 10.1097/00003086-199910000-00027 Barrack, 2004, The effect of stem design on end-of-stem pain in revision total knee arthroplasty, J Arthroplasty, 19, 119, 10.1016/j.arth.2004.06.009 Ingrassia, 2013, Finite element analysis of two total knee prostheses, Int J Interact Des Manuf, 7, 91, 10.1007/s12008-012-0167-7 Sarathi Kopparti, 2007, Influence of three variables on the stresses in a three-dimensional model of a proximal tibia-total knee implant construct, Biomed Mater Eng, 17, 19 Innocenti, 2016, Biomechanical effects of different varus and valgus alignments in medial unicompartmental knee arthroplasty, J Arthroplasty, 31, 2685, 10.1016/j.arth.2016.07.006 Soenen, 2013, Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips?, J Arthroplasty, 28, 1437, 10.1016/j.arth.2013.01.010 Vaninbroukx, 2009, Cementing the femoral component in total arthroplasty: which technique is the best?, Knee, 16, 265, 10.1016/j.knee.2008.11.015 Vanlommel, 2011, Cementing the tibial component in total knee arthroplasty: which technique is the best?, J Arthroplasty, 26, 492, 10.1016/j.arth.2010.01.107 Simpson, 2009, Effect of modular neck variation on bone and cement mantle mechanics around a total hip arthroplasty stem, Clin Biomech, 24, 274, 10.1016/j.clinbiomech.2008.12.010 Innocenti, 2011, Contact forces in several TKA designs during squatting: a numerical sensitivity analysis, J Biomech, 44, 1573, 10.1016/j.jbiomech.2011.02.081 Pianigiani, 2012, Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study, J Biomech, 45, 2315, 10.1016/j.jbiomech.2012.06.014 Pianigiani, 2016, Knee kinetics and kinematics: what are the effects of TKA malconfigurations?, Knee Surg Sports Traumatol Arthrosc, 24, 2415, 10.1007/s00167-015-3514-y Grood, 1983, A joint coordinate system for the clinical description of three-dimensional motions: application to the knee, J Biomech Eng, 105, 136, 10.1115/1.3138397