Analyse de coût comparant les fibroscopes à usage unique (Ambu® aScope™) et les fibroscopes réutilisables pour l’intubation difficile

M. Aïssou1, M. Coroir1, C. Debes1, T. Camus1, N. Hadri2, C. Gutton1, M. Beaussier1
1Département d’anesthésie-réanimation chirurgicale, université Pierre et Marie-Curie Paris 6, hôpital Saint-Antoine, Assistance publique-Hôpitaux de Paris (AP–HP), 184, rue du Faubourg-Saint-Antoine, 75571 Paris cedex 12, France
2Service de pharmacie, université Pierre et Marie-Curie Paris 6, hôpital Saint-Antoine, Assistance publique-Hôpitaux de Paris (AP–HP), 184, rue du Faubourg-Saint-Antoine, 75571 Paris cedex 12, France

Tài liệu tham khảo

American Society of Anesthesiologists Task Force on Management of the Difficult Airway, 2003, Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway, Anesthesiology, 98, 1269, 10.1097/00000542-200305000-00032 Heidegger, 2011, Videos in clinical medicine. Fiberoptic intubation, N Engl J Med, 364, e42, 10.1056/NEJMvcm0906443 Boisson-Bertrand, 1996, Intubation difficile. Société française d’anesthésie et de réanimation. Expertise collective, Ann Fr Anesth Reanim, 15, 207, 10.1016/0750-7658(96)85047-7 Piepho, 2010, Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences, Anaesthesia, 65, 820, 10.1111/j.1365-2044.2010.06406.x Instruction DGOS/R13/2011/449 du 1er décembre 2011 relative à l’actualisation des recommandations visant à réduire les risques de transmission d’agents transmissibles non conventionnels lors des actes invasifs. http://www.sante.gouv.fr/fichiers/bo/2012/12-01/ste_20120001_0100_0098.pdf. Circulaire DHOS/E2/DGS/SDC no 2003-591 du 17 décembre 2003 relative aux modalités de traitement manuel pour la désinfection des endoscopes non autoclaves des les lieux de soins. http://nosobase.chu-lyon.fr/Reglementation/2003/Circulaire/171203.pdf. Gupta, 2011, Cost-effectiveness analysis of flexible optical scopes for tracheal intubation: a descriptive comparative study of reusable and single-use scopes, J Clin Anesth, 23, 632, 10.1016/j.jclinane.2011.04.007 Tvede, 2012, A cost analysis of reusable and disposable flexible optical scopes for intubation, Acta Anaesthesiol Scand, 56, 577, 10.1111/j.1399-6576.2012.02653.x Febvre, 2007, Les bonnes pratiques de la bronchoscopie souple diagnostique, Rev Mal Respir, 24, 1363, 10.1016/S0761-8425(07)78513-3 Hecht G, Hubert G, Subra I, Gagnaire F, Hery M. Évaluation des expositions à l’acide peracetique lors d’opération de désinfection. Hygiène et sécurité du travail. 3eme trimestre 2007. http://www.inrs.fr/accueil/produits/mediatheque/doc/publications.html. Chomel De Varagnes, 2009, Endoscopes bronchiques : bilan de quatre années de contrôles microbiologiques, Rev Mal Respir, 26, 283, 10.1016/S0761-8425(09)72585-9 Ramsey, 2004, An outbreak of bronchoscopy related Mycobacterium tuberculosis infections due to lack of bronchoscope leak testing, Chest, 121, 976, 10.1378/chest.121.3.976 Bou, 2006, Nosocomial outbreak of Pseudomonas infections related to a flexibe bronchoscope, J Hosp Infect, 64, 129, 10.1016/j.jhin.2006.06.014 Seoane-Vazquez, 2007, Endoscopy-related infections and toxic reactions: an international comparison, Endoscopy, 39, 742, 10.1055/s-2007-966504 Diazgranados, 2009, Outbreak of Pseudomonas aeruginosa infection associated with contamination of a flexible bronchoscope, Infect Control Hosp Epidemiol, 30, 550, 10.1086/597235 Chroneou, 2008, Molecular typing of Mycobacterium chelonae isolates from a pseudo-oubreak involving an automated bronchoscope washer, Infect Control Hosp Epidemiol, 29, 1088, 10.1086/591451 Centers for Disease Control and Prevention (CDC), 2009, Pseudo-outbreak of legionnaires disease among patients undergoing bronchoscopy, MMWR Morb Mortal Wkly Rep, 58, 849 Larson, 2003, Potential nosocomial exposure to Mycobacterium tuberculosis from a bronchoscope, Infect Control Hosp Epidemiol, 24, 825, 10.1086/502144 Estebe, 1997, Anesthésie et agents transmissibles non conventionnels (ou maladie à prion), Ann Fr Anesth Reanim, 16, 955, 10.1016/S0750-7658(97)82144-2 Srinivasan, 2004, Bronchoscope reprocessing and infection prevention and control: bronchoscopy-specific guidelines are needed, Chest, 125, 307, 10.1378/chest.125.1.307 Éléments d’assurance qualité en hygiène relatifs au contrôle microbiologique des endoscopes et à la traçabilité en endoscopie. Comité technique des infections nosocomiales et des infections lié aux soins, Conseil supérieur d’hygiène publique en France, 2007. http//nosobase.chu-lyon.fr/recommandations/Dispositif/microbio_endoscopes.pdf consulté le 6 juin 2012. Rozman, 2009, Flexible bronchoscope damage and repair costs in a bronchoscopy teaching unit, Respiration, 77, 325, 10.1159/000188788 Lunn, 2005, Reducing maintenance and repair costs in an interventional pulmonology program, Chest, 127, 1382, 10.1378/chest.127.4.1382 Mehta, 1990, The high price of bronchoscopy. Maintenance and repair of the flexible fiberoptic bronchoscope, Chest, 98, 448, 10.1378/chest.98.2.448 Kirkpatrick, 1992, Bronchoscope damage and repair costs: results of a regional postal survey, Respir Care, 37, 1256