An examination of procedures for determining body segment attitude and position from noisy biomechanical data

Medical Engineering & Physics - Tập 17 - Trang 83-90 - 1995
J.H. Challis1
1Applied Physiology Research Unit, The University of Birmingham, Birmingham, UK

Tài liệu tham khảo

Beggs, 1966, 38 Laub, 1982, A linear algebra approach to the analysis of rigid body displacement from initial and final position data, J Appl Mech, 49, 213, 10.1115/1.3161978 Veldpaus, 1988, A least-squares algorithm for the equiform transformation from spatial marker co-ordinates, J Biomech, 21, 45, 10.1016/0021-9290(88)90190-X Woltring, 1991, Representation and calculation of 3-D joint movement, Hum Move Sci, 10, 603, 10.1016/0167-9457(91)90048-3 Siegler, 1988, The three-dimensional kinematics and flexibility of the human ankle and subtalar joints — Part I: Kinematics, J Biomech Eng, 110, 364, 10.1115/1.3108455 Nikravesh, 1988, 164 Arun, 1987, Least-squares fitting of two 3-d point sets, IEEE Trans Pattern Analysis Machine Intelligence, 9, 698, 10.1109/TPAMI.1987.4767965 Horn, 1989, Closed-form solution of absolute orientation using orthonormal matrices, J Opt Sco Am, A5, 1128 Angeles, 1986, Automatic computation of the screw parameters of rigid-body motions. Part I: Finitely-separated positions, J Mech Automation Design, 108, 32 Small, 1992, Rationalization of kinematic descriptors for three-dimensional hand and finger motion, J Biomed Eng, 14, 133, 10.1016/0141-5425(92)90018-G Chao, 1980, Justification of a triaxial goniometer for the measurement of joint rotation, J Biomech, 13, 989, 10.1016/0021-9290(80)90044-5 Wittenburg, 1977, 19 Lanshammar, 1982, On precision limits for derivatives numerically calculated from noisy data, J Biomech, 15, 459, 10.1016/0021-9290(82)90082-3 Winter, 1974, Measurement and reduction of noise in kinematics of locomotion, J Biomech, 7, 157, 10.1016/0021-9290(74)90056-6 Cavanagh, 1975, Knee joint torque during the swing phase of normal treadmill walking, J Biomech, 8, 337, 10.1016/0021-9290(75)90086-X Gustafsson, 1977, ENOCH — An integrated system for measurement and analysis of human gait, 43 Macleod, 1987, Investigation of inherent experimental noise in kinematic experiments using superficial markers, 1035 Abdel-Aziz, 1974, Expected accuracy of convergent photos, Photogrammetric Eng, 40, 1341 Wood, 1986, The accuracy of DLT extrapolation in three-dimensional film analysis, J Biomech, 19, 781, 10.1016/0021-9290(86)90201-0 van den Bogert, 1990, Correction for skin displacement errors in movement analysis of the horse, J Biomech, 23, 97, 10.1016/0021-9290(90)90374-C Dongarra, 1978 Chadwick, 1976, 19 Gantmacher, 1959, Vol. I, 83