An Umbrella Review of the Effectiveness of Temporary Anchorage Devices and the Factors That Contribute to Their Success or Failure

Journal of Evidence Based Dental Practice - Tập 20 - Trang 101402 - 2020
Diana Milena Ramírez-Ossa1, Natalia Escobar-Correa1, Maria Antonia Ramírez-Bustamante1, Andrés A. Agudelo-Suárez1
1Faculty of Dentistry, University of Antioquia, Medellin, Colombia

Tài liệu tham khảo

Costello, 2010, Temporary skeletal anchorage devices for orthodontics, Oral Maxillofac Surg Clin North Am, 22, 91, 10.1016/j.coms.2009.10.011 Kanomi, 1997, Mini-implant for orthodontic anchorage, J Clin Orthod, 31, 763 Block, 1995, A new device for absolute anchorage for orthodontics, Am J Orthod Dentofacial Orthop, 107, 251, 10.1016/S0889-5406(95)70140-0 Nanda, 2009 Zheng, 2018, Implants for orthodontic anchorage: an overview, Medicine (Baltimore), 97, e0232, 10.1097/MD.0000000000010232 Mohammed, 2018, Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis, Prog Orthod, 19, 36, 10.1186/s40510-018-0225-1 2007 Durrani, 2017, Comparison of in-vivo failure of single-thread and dual-thread temporary anchorage devices over 18 months: a split-mouth randomized controlled trial, Am J Orthod Dentofacial Orthop, 152, 451, 10.1016/j.ajodo.2017.05.019 Assad-Loss, 2017, Fracture strength of orthodontic mini-implants, Dental Press J Orthod, 22, 47, 10.1590/2177-6709.22.3.047-054.oar Tepedino, 2017, Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews–an in vitro study, Head Face Med, 13, 10, 10.1186/s13005-017-0143-3 Gonzalez Del Castillo McGrath, 2018, Mandibular anterior intrusion using miniscrews for skeletal anchorage: a 3-dimensional finite element analysis, Am J Orthod Dentofacial Orthop, 154, 469, 10.1016/j.ajodo.2018.01.009 Chen, 2009, Critical factors for the success of orthodontic mini-implants: a systematic review, Am J Orthod Dentofacial Orthop, 135, 284, 10.1016/j.ajodo.2007.08.017 Reynders, 2009, Mini-implants in orthodontics: a systematic review of the literature, Am J Orthod Dentofacial Orthop, 135, 564.e1, 10.1016/j.ajodo.2008.09.026 Schatzle, 2009, Survival and failure rates of orthodontic temporary anchorage devices: a systematic review, Clin Oral Implants Res, 20, 1351, 10.1111/j.1600-0501.2009.01754.x 2014 Aromataris, 2015, Summarizing systematic reviews: methodological development, conduct and reporting of an umbrella review approach, Int J Evid Based Healthc, 13, 132, 10.1097/XEB.0000000000000055 Higgins, 2008 Crismani, 2010, Miniscrews in orthodontic treatment: review and analysis of published clinical trials, Am J Orthod Dentofacial Orthop, 137, 108, 10.1016/j.ajodo.2008.01.027 Papadopoulos, 2011, Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis, J Dent Res, 90, 969, 10.1177/0022034511409236 Papageorgiou, 2012, Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis, Am J Orthod Dentofacial Orthop, 142, 577, 10.1016/j.ajodo.2012.05.016 Meursinge Reynders, 2012, Insertion torque and success of orthodontic mini-implants: a systematic review, Am J Orthod Dentofacial Orthop, 142, 596, 10.1016/j.ajodo.2012.06.013 Tsui, 2012, Bone anchor systems for orthodontic application: a systematic review, Int J Oral Maxillofac Surg, 41, 1427, 10.1016/j.ijom.2012.05.011 Dalessandri, 2014, Determinants for success rates of temporary anchorage devices in orthodontics: a meta-analysis (n > 50), Eur J Orthod, 36, 303, 10.1093/ejo/cjt049 Hong, 2016, Prognostic factors associated with the success rates of posterior orthodontic miniscrew implants: a subgroup meta-analysis, Korean J Orthod, 46, 111, 10.4041/kjod.2016.46.2.111 Leo, 2016, Temporary anchorage devices (TADs) in orthodontics: review of the factors that influence the clinical success rate of the mini-implants, Clin Ter, 167, e70 Antoszewska-Smith, 2017, Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during en-masse retraction: a systematic review and meta-analysis, Am J Orthod Dentofacial Orthop, 151, 440, 10.1016/j.ajodo.2016.08.029 Cunha, 2017, How do geometry-related parameters influence the clinical performance of orthodontic mini-implants? A systematic review and meta-analysis, Int J Oral Maxillofac Surg, 46, 1539, 10.1016/j.ijom.2017.06.010 Gintautaite, 2017, Surgery-related factors affecting the stability of orthodontic mini implants screwed in alveolar process interdental spaces: a systematic literature review, Stomatologija, 19, 10 Alharbi, 2018, Miniscrews failure rate in orthodontics: systematic review and meta-analysis, Eur J Orthod, 40, 519, 10.1093/ejo/cjx093 Becker, 2018, Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis, Int J Implant Dent, 4, 35, 10.1186/s40729-018-0144-4 Moher, 2009, Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement, Ann Intern Medicine, 151, 264, 10.7326/0003-4819-151-4-200908180-00135 Shea, 2017, AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both, BMJ, 358, j4008, 10.1136/bmj.j4008 Sharif, 2013, Systematic reviews explained: AMSTAR-how to tell the good from the bad and the ugly, Oral Health Dent Manag, 12, 9 Feldmann, 2006, Orthodontic anchorage: a systematic review, Angle Orthod, 76, 493 Stang, 2010, Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses, Eur J Epidemiol, 25, 603, 10.1007/s10654-010-9491-z Sterne, 2016, ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions, BMJ, 355, i4919, 10.1136/bmj.i4919 Atkins, 2004, Grading quality of evidence and strength of recommendations, BMJ, 328, 1490, 10.1136/bmj.328.7454.1490 Antczak, 1986, Quality assessment of randomized control trials in dental research. I. Methods, J Periodontal Res, 21, 305, 10.1111/j.1600-0765.1986.tb01464.x Jadad, 1996, Assessing the quality of reports of randomized clinical trials: is blinding necessary?, Control Clin Trials, 17, 1, 10.1016/0197-2456(95)00134-4 Wehrbein, 1996, The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem, Clin Oral Implants Res, 7, 410, 10.1034/j.1600-0501.1996.070416.x Melsen, 2005, Mini-implants: where are we?, J Clin Orthod, 39, 539 De Clerck, 2009, Orthopedic traction of the maxilla with miniplates: a new perspective for treatment of midface deficiency, J Oral Maxillofac Surg, 67, 2123, 10.1016/j.joms.2009.03.007 Kuroda, 2007, Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort, Am J Orthod Dentofacial Orthop, 131, 9, 10.1016/j.ajodo.2005.02.032 Park, 2006, Factors affecting the clinical success of screw implants used as orthodontic anchorage, Am J Orthod Dentofacial Orthop, 130, 18, 10.1016/j.ajodo.2004.11.032 Chaddad, 2008, Influence of surface characteristics on survival rates of mini-implants, Angle Orthod, 78, 107, 10.2319/100206-401.1 Kim, 2009, Rotational resistance of surface-treated mini-implants, Angle Orthod, 79, 899, 10.2319/090608-466.1 Motoyoshi, 2010, Factors affecting the long-term stability of orthodontic mini-implants, Am J Orthod Dentofacial Orthop, 137, 588.e1, 10.1016/j.ajodo.2009.05.019 Suzuki, 2011, Placement and removal torque values of orthodontic miniscrew implants, Am J Orthod Dentofacial Orthop, 139, 669, 10.1016/j.ajodo.2010.11.017 Lee, 2010, Survival analysis of orthodontic mini-implants, Am J Orthod Dentofacial Orthop, 137, 194, 10.1016/j.ajodo.2008.03.031 Cheng, 2004, A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage, Int J Oral Maxillofac Implants, 19, 100 Chen, 2007, A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems, Clin Oral Implants Res, 18, 768, 10.1111/j.1600-0501.2007.01405.x Lim, 2009, Factors associated with initial stability of miniscrews for orthodontic treatment, Am J Orthod Dentofacial Orthop, 136, 236, 10.1016/j.ajodo.2007.07.030 Shinohara, 2013, Root proximity and inclination of orthodontic mini-implants after placement: cone-beam computed tomography evaluation, Am J Orthod Dentofacial Orthop, 144, 50, 10.1016/j.ajodo.2013.02.021 Manni, 2011, Factors influencing the stability of miniscrews. A retrospective study on 300 miniscrews, Eur J Orthod, 33, 388, 10.1093/ejo/cjq090 Lai, 2014, Factors affecting the clinical success of orthodontic anchorage: experience with 266 temporary anchorage devices, J Dent Sci, 9, 49 Sharma, 2011, Success rate of microimplants in a university orthodontic clinic, ISRN Surg, 2011, 982671, 10.5402/2011/982671 Lim, 2011, Predictors of initial stability of orthodontic miniscrew implants, Eur J Orthod, 33, 528, 10.1093/ejo/cjq122 Wu, 2009, Factors associated with the stability of mini-implants for orthodontic anchorage: a study of 414 samples in Taiwan, J Oral Maxillofac Surg, 67, 1595, 10.1016/j.joms.2009.04.015 Watanabe, 2013, Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density, Orthod Craniofac Res, 16, 44, 10.1111/ocr.12003 Tezel, 2001, The effect of right or left-handedness on oral hygiene, Int J Neurosci, 109, 1, 10.3109/00207450108986521 Uribe, 2015, Failure rates of mini-implants placed in the infrazygomatic region, Prog Orthod, 16, 31, 10.1186/s40510-015-0100-2 Freudenthaler, 2001, Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications, Clin Oral Implants Res, 12, 358, 10.1034/j.1600-0501.2001.012004358.x Thiruvenkatachari, 2006, Comparison and measurement of the amount of anchorage loss of the molars with and without the use of implant anchorage during canine retraction, Am J Orthod Dentofacial Orthop, 129, 551, 10.1016/j.ajodo.2005.12.014 Bayat, 2010, Effect of smoking on the failure rates of orthodontic miniscrews, J Orofac Orthop, 71, 117 Motoyoshi, 2006, Recommended placement torque when tightening an orthodontic mini-implant, Clin Oral Implants Res, 17, 109, 10.1111/j.1600-0501.2005.01211.x Motoyoshi, 2007, Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants, Int J Oral Maxillofac Implants, 22, 779 Kim, 2010, Cone-beam computed tomography evaluation of mini-implants after placement: is root proximity a major risk factor for failure?, Am J Orthod Dentofacial Orthop, 138, 264, 10.1016/j.ajodo.2008.07.026 Kim, 2010, Midpalatal miniscrews for orthodontic anchorage: factors affecting clinical success, Am J Orthod Dentofacial Orthop, 137, 66, 10.1016/j.ajodo.2007.11.036 Kang, 2011, Control of maxillary dentition with 2 midpalatal orthodontic miniscrews, Am J Orthod Dentofacial Orthop, 140, 879, 10.1016/j.ajodo.2010.02.040 Isidor, 2006, Influence of forces on peri-implant bone, Clin Oral Implants Res, 17, 8, 10.1111/j.1600-0501.2006.01360.x